In this paper, an improved induction motor (IM) stator flux estimation method is proposed, based on a novel integrator scheme with a closed-loop dc offset compensation algorithm. When compared with the existing stator flux estimators, the proposed solution represents an improved programmable low-pass filter. Namely, by introducing a novel closed-loop dc offset compensation structure, two major drawbacks of existing stator flux estimators are overcome; their stability and accuracy at low frequencies, and the estimator response time over the whole frequency range, introducing an estimation algorithm much simpler than existing solutions. The performance of the novel stator flux estimator is tested by means of simulation runs and experimental tests, with the proposed algorithm used for the estimation of the stator flux, rotor flux, and rotor speed in a direct field-oriented controlled IM control algorithm. The simulations and experimental results show that the proposed estimator enables accurate and stable operation under all operating conditions, including the critical low stator frequency range.
27 September 2022 in International Journal of Electrical Power & Energy Systems
Single‐phase phase‐locked loops (PLLs) are used in various types of power electronics applications, including voltage source inverters, pulse width modulation rectifiers and different types of grid‐tied power converter utilities. The orthogonal signal generators (OSGs), used in single‐phase PLLs, are generally based on various types of filters, and they need to operate robustly in relation to the grid voltage disturbances and frequency variations. In this study, a novel OSG is proposed based on a modified first‐order all‐pass filter, which enables the PLL phase detector to operate at different response speeds, tuned by means of a single parameter. The PLL is experimentally verified and compared with a number of conventional solutions. Tests include responses to phase angle disturbances, frequency steps, and PLL input voltage distortions. Results show that a novel OSG filter enables faster PLL responses when compared with several conventional OSG filters, all designed to have the same disturbance attenuation at double fundamental frequency.
10 June 2015 in IEEE Transactions on Energy Conversion
In this paper, a novel induction motor (IM) stator current controller is proposed based on the stationary frame feed forward controlling structure. The proposed regulator represents an improved variant of the existing stationary and rotational frame IM stator current regulators based on the back EMF compensation. The paper novelty consists of the stationary frame controlling structure based on two feed forward actions that enable asymptotic reference tracking. Namely, the novel stationary frame regulator includes a proportional integral (PI) regulation term combined with a stator resistance voltage drop and back EMF feed forward compensations, with the back EMF compensation based on the stator flux value estimated by means of a programmable low-pass filter. The feedback term is based on a PI controller, with the corresponding parameter tuning procedure outlined in the paper. The simulation runs are included in the paper in order to examine the regulator performance in relation to the factors critical to the IM stator current regulation: variable IM model parameter values, transport delay introduced in the control loop, variable stator frequency, and rotor speed values. Also, the experimental tests are presented and carried out on an experimental setup for different operating conditions typical for an IM drive.
13 July 2022 in IEEE Journal of Emerging and Selected Topics in Power Electronics
In this paper, a digital resonant current controller is proposed for pulse width modulation (PWM) control of an LCL-filtered inverter based on a modified current sampling method and time delay modeling. Since the current sampling technique employed here uses a freely tunable sampling instant within the PWM signal period, a corresponding LCL filter model discretization technique is used based on a modified Z-transform. This is applied to model the fractional delay introduced by the current sampling technique, which uses sampling instants from within the PWM signal period. Modified Z-transform-based delay modeling has not previously been employed for LCL-filtered inverters, although it has been used in inverters with an RL load. The proposed technique is implemented with a fifth-order current controller, which directly controls the power converter AC output current without the need for active damping, as is typical for converters with LCL filters. A method based on pole placement is adopted to tune the controller parameters, in which the positions of all the closed-loop poles of the control system are determined. The responses of the controller to reference and disturbance signals are analyzed through simulation and experimental testing for different sampling instants within the PWM signal period.
29 August 2023 in IEEE Transactions on Power Electronics
In recent years, there has been a notable tendency toward reducing the number of power conversion stages in electric vehicle (EV) charging applications based on inductive power transfer. Matrix converter topology presents itself as an attractive solution due to its known benefits of having the high power density and small volume. However, its control is challenging. In this article, we propose a novel modulation strategy of the three-phase to single-phase matrix converter that ensures stable power flow between the grid and the EV. The proposed control method enables the processing of the reactive power by the matrix converter while keeping low THD of grid currents and high PF. A compensation circuit based on the third winding and accompanying resonant circuit that is suitable for this application is presented. The problem of power flow control in these systems is analyzed, and the answer is put forward, excluding any type of wireless communication between the two microcontrollers controlling the system. An experimental setup was built to verify the proposed ideas. A power transfer of 3.6 kW was achieved over an air gap of 40 mm with an overall efficiency of 95.15% with 3.2% THD of the grid currents and 0.975 PF.