Alexis Jacquier

Prof. Dr. Alexis Jacquier


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2010 in European Heart Journal
Verified
Journal Article
Open access
PDF file
AJAlexis Jacquier
Alexis Jacquier
FTFranck Thuny
Franck Thuny
BJBertrand Jop
Bertrand Jop
RGRoch Giorgi
Roch Giorgi
FCFrederic Cohen
Frederic Cohen
GMGuy Moulin
Guy Moulin
To describe a method for measuring trabeculated left ventricular (LV) mass using cardiac magnetic resonance imaging and to assess its value in the diagnosis of left ventricular non-compaction (LVNC). Between January 2003 and 2008, we prospectively included 16 patients with LVNC. During the mean period, we included 16 patients with dilated cardiomyopathy (DCM), 16 patients with hypertrophic cardiomyopathy (HCM), and 16 control subjects. Left ventricular volumes, LV ejection fraction, and trabeculated LV mass were measured in the four different populations. The percentage of trabeculated LV mass was almost three times higher in the patients with LVNC (32 ± 10%), compared with those with DCM (11 ± 4%, P < 0.0001), HCM (12 ± 4%, P < 0.0001), and controls (12 ± 5%, P < 0.0001). A value of trabeculated LV mass above 20% of the global mass of the LV predicted the diagnosis of LVNC with a sensitivity of 93.7% [95% confidence interval (CI), 71.6–98.8%] and a specificity of 93.7% (95% CI, 83.1–97.8%; κ = 0.84). The method described is reproducible and provides an assessment of the global amount of LV trabeculation. A trabeculated LV mass above 20% of the global LV mass is highly sensitive and specific for the diagnosis of LVNC.

1 June 2022 in Radiology
Verified
Journal Article
Closed access
FCFarah Cadour
Farah Cadour
JCJennifer Cautela
Jennifer Cautela
SRStanislas Rapacchi
Stanislas Rapacchi
AVArthur Varoquaux
Arthur Varoquaux
PHPaul Habert
Paul Habert
FTFranck Thuny
Franck Thuny
Myocardial T1 and T2 mapping and late gadolinium enhancement (LGE) features of immune checkpoint inhibitor (ICI)–induced myocarditis (ICI-M) were different from those in patients with cancer before... Background Cardiac MRI features are not well-defined in immune checkpoint inhibitor (ICI)–induced myocarditis (ICI-M), a severe complication of ICI therapy in patients with cancer. Purpose To analy...

1 February 2021 in Radiology
Verified
Journal Article
Closed access
GHGuillaume HERPE
Guillaume HERPE
MLMathieu Lederlin
Mathieu Lederlin
MNMathieu Naudin
Mathieu Naudin
MOMickaël Ohana
Mickaël Ohana
KCKathia Chaumoitre
Kathia Chaumoitre
JTJean Pierre Tasu
Jean Pierre Tasu
Background The role and performance of chest CT in the diagnosis of the coronavirus disease 2019 (COVID-19) pandemic remains under active investigation. Purpose To evaluate the French national expe...

1 June 2020 in Radiology
Verified
Journal Article
Closed access
OMOlivier Meyrignac
Olivier Meyrignac
LBLaurence Bal
Laurence Bal
CZCharline Zadro
Charline Zadro
AVAdrien Vavasseur
Adrien Vavasseur
ASAnou Sewonu
Anou Sewonu
RMRamiro Moreno
Ramiro Moreno
A regression model incorporating aneurysm lumen volume and wall shear stress was better than maximal diameter to predict growth of abdominal aortic aneurysms smaller than 50 mm. Background Despite known limitations, the decision to operate on abdominal aortic aneurysm (AAA) is primarily on the basis of measurement of maximal aneurysm diameter. Purpose To identify volumetri...

16 September 2014 in Insights into Imaging
Verified
Journal Article
Open access
PDF file
AGAnaïs Grob
Anaïs Grob
FTFranck Thuny
Franck Thuny
CVChloe Villacampa
Chloe Villacampa
AFAntonin Flavian
Antonin Flavian
JGJean Yves Gaubert
Jean Yves Gaubert
AJAlexis Jacquier
Alexis Jacquier
Objectives The goals of this pictorial essay are: (1) to set out a multislice computed tomography (MSCT) imaging protocol to assess infective endocarditis (IE); (2) to give an MSCT overview of valvular and peri-valvular involvement during IE; (3) to give a CT overview of septic embolism and infectious pseudoaneurysms during IE. Methods MSCT acquisition protocols to assess IE are performed in two different phases: the first acquisition, under electrocardiography (ECG) gating, covers the cardiac structures during first-pass iodine injection; the second acquisition covers the thorax, abdomen, pelvic and cerebral regions. Results Valvular and peri-valvular lesions during IE are: vegetation—a hypodense, homogeneous, irregular mass on a valve or endocardial structure; perforation—a defect in the leaflet; valvular aneurysm—loss of the homogenous curvature of the leaflet; valvular thickening; peri-valvular abscess; pseudoaneurysm; fistula and disinsertion of a prosthetic valve. Extra-cardiac location could involve all organs. Conclusions MSCT can be considered as a useful complement in visualising the cardiac lesions of IE if echocardiography is inconclusive. MSCT is the only imaging modality that provides assessment of valvular and peri-valvular involvement, extra-cardiac lesions, and non-invasive evaluation of the coronary artery anatomy, simultaneously. Main Messages • MSCT provides assessment of coronary anatomy, cardiac and extra-cardiac lesions. • MSCT represents an alternative to echocardiography during IE. • Surgical valve replacement is usually required if vegetation is >10 mm. • Peri-valvular extension (abscesses, pseudoaneurysm and fistulae) required surgical treatment.

1 November 2008 in Investigative Radiology
Verified
Journal Article
Closed access
AJAlexis Jacquier
Alexis Jacquier
LBLoïc Boussel
Loïc Boussel
NANicolas Amabile
Nicolas Amabile
JBJean Michel Bartoli
Jean Michel Bartoli
PDPhilipe Douek
Philipe Douek
PCPierre Croisille
Pierre Croisille
(1) To determine the accuracy of delayed enhancement multidetector computed tomography (MDCT) in measuring the extent of acute myocardial infarct and no-reflow areas using cardiac magnetic resonance imaging (MRI) as standard of reference and (2) to define the optimum timing between injection and MDCT image acquisition to characterize infarcted myocardium and no-reflow areas after reperfusion therapy. Nineteen patients were prospectively included after acute myocardial infarction and revascularization. Each patient had an MDCT acquisition before and 5 and 10 minutes after injection of 1.5 mL/kg iodinated contrast medium, and a contrast-enhanced MRI at 5 and 10 minutes after injection of 0.2 mmol/kg gadolinium chelate. We assessed image quality and infarct extent using MDCT and MRI, and we measured parameters related to iodinated contrast media kinetics (DeltaHU and DeltaHU ratio). The areas of hyperenhanced myocardium located on the MDCT corresponded to the occluded vessel located on the coronary angiogram (kappa = 0.9). There were strong correlations between the extent of hyperenhanced infarcted myocardium on MDCT and MRI at 5 minutes (20.4% +/- 2.7% of left ventricle (LV) and 20.9% +/- 2.4%, respectively, R = 0.85; P < 0.0001) and 10 minutes after injection (21.0% +/- 2.9% of LV and 19.4% +/- 2.5%, respectively, R = 0.80; P < 0.0001). However, the correlation between the area of hypoenhanced myocardium measured using MDCT and CMR 5 minutes after injection (R = 0.86; P < 0.0001) was better than the measurement obtained 10 minutes after injection (R = 0.64; P = 0.002). On contrast-enhanced MDCT, 5 minutes after injection, the signal-to-noise ratio was significantly higher than at 10 minutes after injection in LV blood (28 +/- 1 to 21 +/- 1, respectively; P = 0.0007), normal myocardium (18 +/- 1 to 15 +/- 1; P = 0.0009), and hyperenhanced infarcted myocardium (24 +/- 1 to 20 +/- 1; P = 0.004). MDCT image quality was significantly better at 5 minutes (3.2 +/- 0.1) than at 10 minutes (2.8 +/- 0.2, P = 0.01, kappa = 0.4). The DeltaHU ratio increased slightly but significantly between 5 minutes (0.83 +/- 0.01) and 10 minutes (0.93 +/- 0.01; P = 0.01), suggesting a slow wash-in and wash-out of contrast medium in infarcted myocardium. In ST segment elevation myocardial infarction patients contrast-enhanced MDCT is an accurate method for characterizing and sizing myocardial infarct and no-reflow. Contrast-enhanced MDCT performed 5 minutes after injection yields a higher signal-to-noise ratio and image quality than the 10 minutes time point with no difference in the extent of infarct measurement.