The COVID-19 pandemic has underscored the shortcomings in the deployment of state-of-the-art diagnostics platforms. Although several polymerase chain reaction (PCR)-based techniques have been rapidly developed to meet the growing testing needs, such techniques often need samples collected through a swab, the use of RNA extraction kits, and expensive thermocyclers in order to successfully perform the test. Isothermal amplification-based approaches have also been recently demonstrated for rapid severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection by minimizing sample preparation while also reducing the instrumentation and reaction complexity. In addition, there are limited reports of saliva as the sample source, and some of these indicate inferior sensitivity when comparing reverse transcription loop-mediated isothermal amplification (RT-LAMP) with PCR-based techniques. In this paper, we demonstrate an improved sensitivity assay from saliva using a two-step RT-LAMP assay, where a short 10 min RT step is performed with only B3 and backward inner primers before the final reaction. We show that while the one-step RT-LAMP demonstrates satisfactory results, the optimized two-step approach allows detection of only few molecules per reaction and performs significantly better than the one-step RT-LAMP and conventional two-step RT-LAMP approaches with all primers included in the RT step. We show control measurements with RT-PCR, and importantly, we demonstrate RNA extraction-free RT-LAMP-based assays for detection of SARS-CoV-2 from viral transport media and saliva clinical samples.
19 April 2018 in Environmental Science & Technology
Noroviruses (NoVs) cause over 90% of non-bacterial gastroenteritis outbreaks in adults and children in developed countries. Therefore, there is a need for approaches to mitigate the transmission of noroviruses in workplaces to reduce their substantial health burden. We developed and validated a low-cost, autonomous robot called the UVBot to disinfect occupational spaces using ultraviolet (UV) lamps. The total cost of the UVBOT is less than USD 1000, which is much lower than existing commercial robots that cost as much as USD 35,000. The user-friendly desktop application allows users to control the robot remotely, check the disinfection map, and add virtual walls to the map. A 2D LiDAR and a simultaneous localization and mapping (SLAM) algorithm was used to generate a map of the space being disinfected. Tulane virus (TV), a human norovirus surrogate, was used to validate the UVBot’s effectiveness. TV was deposited on a painted drywall and exposed to UV radiation at different doses. A 3-log (99.9%) reduction of TV infectivity was achieved at a UV dose of 45 mJ/cm2. We further calculated the sanitizing speed as 3.5 cm/s and the efficient sanitizing distance reached up to 40 cm from the UV bulb. The design, software, and environment test data are available to the public so that any organization with minimal engineering capabilities can reproduce the UVBot system.
A novel microplasma jet array was developed under 3D printing platform with resolution as high as 50 um to disinfect the virus in water. The reactive oxygen species, recognized as the key component for the disinfection process, produced through microplasma in liquid and quantified with two chemical probes. The positive correlation was observed between plasma power dosages and radicals concentrations. The concentration of OH radical was achieved within nM range, while the concentration of 1 O 2 is sub-μM. The long lived species, like H 2 O 2 and O 3 , were also monitored to probe the long-lasting oxidation effect from microplasma treatment in liquid. The realization of the microplasma array beyond two dimensions provides a powerful tool for un-flat surface. The innovations of the microplasma through 3D printing techniques provide a promising method for disinfection treatment in water distribution system. The detailed experiment findings will be introduced in the conference.