Reem Abdullah Alsaigh

Dr. Reem Abdullah Alsaigh


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 April 2024 in Crystals
Verified
Journal Article
Open access
PDF file
RAReem Abdullah Alsaigh
Reem Abdullah Alsaigh
Surface texturing, which has recently garnered increased attention, involves modifying the surface texture of materials to enhance their tribology. Various methods have been developed for surface texturing. Laser surface texturing (LST) has attracted considerable interest because of its excellent texturing accuracy, controllability, and flexibility. It improves surface wettability properties and increases the wear resistance of materials while reducing the coefficient of friction. Herein, we present an overview of the underlying mechanisms of interactions between short-pulsed lasers and materials. In addition, we review published studies on the effects of LST on surface properties, including surface roughness, wettability, friction, and wear resistance. We believe that this review will provide valuable insights into the recent advances in surface property enhancement through LST, which exhibits potential for various applications.

29 April 2021 in Polymers
Verified
Journal Article
Open access
PDF file
MAMamduh Aljaafreh
Mamduh Aljaafreh
SPSaradh Prasad
Saradh Prasad
MAMohamad Alsalhi
Mohamad Alsalhi
RARaya H. Alhandel
Raya H. Alhandel
RAReem Abdullah Alsaigh
Reem Abdullah Alsaigh
In this work, we investigate the TD-DFT simulation, optical, and mirrorless laser properties of conjugated polymer (CP) Poly[(9,9-dioctylfluorenyl-2,7-diyl)-co-(1,4-diphenylene-vinylene-2-methoxy-5-{2-ethylhexyloxy}-benzene)], also known as (PFO-co-PPV-MEHB) or ADS125GE. TD-DFT calculations were performed for three monomer units with truncated tails using time-dependent density functional theory (TD-DFT) calculations. The calculations showed a highest occupied and lowest unoccupied molecular orbital (HOMO-LUMO) structure and a very high oscillator strength of 6.434 for the singlet-singlet transition at 374.43 nm. Experimentally, the absorption and fluorescence spectra were examined at various concentrations in verity of solvents, such as benzene, toluene, and hexane. The experimental results obtained in hexane were comparable with theoretical UV-VIS spectra calculated under vacuum. Amplified spontaneous emission (ASE) spectra peaked at approximately 509 nm for CO PFO-co-PPV-MEHB in solution and were obtained at suitable concentrations and pump energies. Additionally, the photochemical stability of this CP and coumarin (C510) were compared. Time-resolved spectroscopy (TRS) studies with a sub-nanosecond resolution were performed for the CO under various pump energies. These results showed the excited state dynamics and single-pass optical gain of CO PFO-co-PPV-MEHB.

1 November 2022 in Chemosensors
Verified
Journal Article
Open access
PDF file
RAReem Abdullah Alsaigh
Reem Abdullah Alsaigh
SRShofiur Rahman
Shofiur Rahman
FAFATIMAH alfaifi
FATIMAH alfaifi
MAMahmoud AL-Gawati
Mahmoud AL-Gawati
RSRaghad Shallaa
Raghad Shallaa
PGParis Elias Georghiou
Paris Elias Georghiou
Micromechanical sensors, in which the sensor response is created as a result of molecular interactions on the sensors’ surfaces, have been employed as a powerful technique for rapid and sensitive detection of low concentrations of chemical and biological materials. In the study reported herein, poly(methyl methacrylate) (PMMA)-coated microcantilever (MCL) sensors were used to detect the vapors of volatile alcohols (methanol, ethanol, and isopropanol) at three different concentrations. A vapor generator was used to generate and flow the alcohol vapor onto the PMMA coated MCL surface in a closed system chamber. The vapor adsorption onto the MCL surface results in a rapid and measurable deflection of the MCL. No significant deflections of the uncoated MCL occurred when the different vapors were passed through into the microcantilever chamber. Linear concentration–deflection responses were observed, with the highest sensitivity shown with methanol, followed by ethanol and then isopropanol. Density functional theory (DFT) quantum chemical calculations were conducted to estimate the electronic interaction energies (ΔIE) between the alcohol molecules and MMA and two different model tetrameric segments of PMMA. The computed ΔIEs were in the same order as the experimentally observed order: methanol > ethanol > isopropanol.

25 May 2023 in Micromachines
Verified
Journal Article
Open access
PDF file
AAAbeer F Alshammari
Abeer F Alshammari
SASabaa Talal Abdulmawla
Sabaa Talal Abdulmawla
RAReem Abdullah Alsaigh
Reem Abdullah Alsaigh
KAKhaloud Alarjani
Khaloud Alarjani
NANorah Salim Aldosari
Norah Salim Aldosari
AAAbdullah Alodhayb
Abdullah Alodhayb
The quantitative evaluation of bacterial populations is required in many studies, particularly in the field of microbiology. The current techniques can be time-consuming and require a large volume of samples and trained laboratory personnel. In this regard, on-site, easy-to-use, and direct detection techniques are desirable. In this study, a quartz tuning fork (QTF) was investigated for the real-time detection of E. coli in different media, as well as the ability to determine the bacterial state and correlate the QTF parameters to the bacterial concentration. QTFs that are commercially available can also be used as sensitive sensors of viscosity and density by determining the QTFs’ damping and resonance frequency. As a result, the influence of viscous biofilm adhered to its surface should be detectable. First, the response of a QTF to different media without E. coli was investigated, and Luria–Bertani broth (LB) growth medium caused the largest change in frequency. Then, the QTF was tested against different concentrations of E. coli (i.e., 102–105 colony-forming units per milliliter (CFU/mL)). As the E. coli concentration increased, the frequency decreased from 32.836 to 32.242 kHz. Similarly, the quality factor decreased with the increasing E. coli concentration. With a coefficient (R) of 0.955, a linear correlation between the QTF parameters and bacterial concentration was established with a 26 CFU/mL detection limit. Furthermore, a considerable change in frequency was observed against live and dead cells in different media. These observations demonstrate the ability of QTFs to distinguish between different bacterial states. QTFs allow real-time, rapid, low-cost, and non-destructive microbial enumeration testing that requires only a small volume of liquid sample.