Krittika Goyal

Krittika Goyal


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in Sensors
Verified
Journal Article
Open access
PDF file
KGKrittika Goyal
Krittika Goyal
David BorkholderDavid Borkholder
David Borkholder
SDSteven W Day
Steven W Day
Dry electrodes offer an accessible continuous acquisition of biopotential signals as part of current in-home monitoring systems but often face challenges of high-contact impedance that results in poor signal quality. The performance of dry electrodes could be affected by electrode material and skin hydration. Herein, we investigate these dependencies using a circuit skin-electrode interface model, varying material and hydration in controlled benchtop experiments on a biomimetic skin phantom simulating dry and hydrated skin. Results of the model demonstrate the contribution of the individual components in the circuit to total impedance and assist in understanding the role of electrode material in the mechanistic principle of dry electrodes. Validation was performed by conducting in vivo skin-electrode contact impedance measurements across ten normative human subjects. Further, the impact of the electrode on biopotential signal quality was evaluated by demonstrating an ability to capture clinically relevant electrocardiogram signals by using dry electrodes integrated into a toilet seat cardiovascular monitoring system. Titanium electrodes resulted in better signal quality than stainless steel electrodes. Results suggest that relative permittivity of native oxide of electrode material come into contact with the skin contributes to the interface impedance, and can lead to enhancement in the capacitive coupling of biopotential signals, especially in dry skin individuals.

13 March 2024
Verified
Book Chapter
Open access
PDF file
KGKrittika Goyal
Krittika Goyal
SDSteven W. Day
Steven W. Day
In-home physiological monitoring devices enable the monitoring of vital health parameters and can facilitate health recovery. The current state of the art is inclined towards non-invasive technologies such as wearable mobile devices and patch-based sensors. In this chapter, we provide an overview of progress made in the field of dry electrodes for biopotential acquisition, based on their mechanistic principles, materials, testing methods, and effectiveness in a real-world setting. Important parameters affecting the dry electrode performance such as the area, material, applied pressure and skin hydration are discussed. Traditionally, the development and testing of these wearable electrodes are conducted empirically, in vivo on human skin. However, due to the inter- and intra-subject variability in human skin properties, reliability, repeatability, and the efficacy of the device under investigation cannot be evaluated. Thus a review is presented about the skin phantoms used to simulate the electrical properties of the skin, which has the potential to serve as a robust method to test the functionality of current and future electrodes. This retrospective overview provides researchers with an understanding of the mechanistic principle of biopotential electrodes and the crucial factors that affect electrode performance, thus facilitating wearable electrode development.