Christian Mahnkopf

Dr. Christian Mahnkopf


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MAMhd Nawar Alachkar
Mhd Nawar Alachkar
SSSteffen Schnupp
Steffen Schnupp
AEAstrid Eichelsdoerfer
Astrid Eichelsdoerfer
AMAndrea Milzi
Andrea Milzi
HMHesham Mady
Hesham Mady
CMChristian Mahnkopf
Christian Mahnkopf
Background: Transcatheter tricuspid valve repair using the edge-to-edge-technique (TEER) has emerged as an alternative therapy in patients with severe tricuspid regurgitation (TR) and high surgical risk. This study aimed to evaluate the feasibility and efficacy of tricuspid valve TEER in patients with cardiac implanted electric devices (CIEDs). Methods: All patients who underwent tricuspid valve TEER at our center were retrospectively included. Patients were classified according to the presence of CIEDs. Procedure success was defined as implantation of at least one clip and the reduction of TR of at least one grade. Procedure success and intrahospital outcome were compared between the two groups. Results: One-hundred and six consecutive patients underwent tricuspid TEER (age 80.1 ± 6.4 years, male = 42; 39.6%). Among them, 25 patients (23.6%, age 80.6 ± 7.3 years, male = 14; 56%) had CIEDs. Patients with CIEDs had a significantly lower left ventricular ejection fraction (LV-EF) compared to those without CIEDs (47.2 ± 15% vs. 56.2 ± 8.2%, p = 0.004, respectively). Moreover, arterial hypertension was more common in patients with CIEDs (96% vs. 79%, p = 0.048). The success of the procedure did not differ between the non-CIED vs. CIED group (93.8% vs. 92%, p = 0.748). Furthermore, the number and position of implanted clips, the duration of the procedure, the post-procedural pressure gradient across the tricuspid valve, and post-procedural TR severity were comparable between both groups. Conclusion: Tricuspid valve TEER is feasible and efficient in patients with CIEDs. The success of the procedure, as well as the intrahospital outcome were comparable between patients with and without CIEDs.

4 February 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MFMathias Forkmann
Mathias Forkmann
CMChristian Mahnkopf
Christian Mahnkopf
MMMarcel Mitlacher
Marcel Mitlacher
MWMarc Wolff
Marc Wolff
BPBeatriz Tose Costa Paiva
Beatriz Tose Costa Paiva
SBSonia Busch
Sonia Busch
(1) Background: The modified anterior line (MAL) has been described as an alternative to the mitral isthmus line. Despite better ablation results, achieving a bidirectional line block can be challenging. We aimed to investigate the ablation parameters that determine a persistent scar on late-gadolinium enhancement magnet resonance imaging (LGE-MRI) as a surrogate parameter for successful ablation 3 months after MAL ablation. (2) Methods: Twenty-four consecutive patients who underwent a MAL ablation have been included. The indication for MAL was perimitral flutter (n = 5) or substrate ablation in the diffuse anterior left atrial (LA) low-voltage area in persistent atrial fibrillation (AF) (n = 19). The MAL was divided into three segments: segment 1 (S1) from mitral annulus to height of lower region of left atrial appendage (LAA) antrum; segment 2 (S2) height of lower region of LAA antrum to end of upper LAA antrum; segment 3 (S3) from end of upper LAA antrum to left superior pulmonary vein. Ablation was performed using a contact force irrigated catheter with a power of 40 Watt and guided by automated lesion tagging and the Ablation Index (AI). The AI target was left to the operator’s choice. An inter-lesion distance of ≤6 mm was recommended. The bidirectional block was systematically evaluated using stimulation maneuvers at the end of procedure. All patients underwent LGE-MRI imaging at 3 months, regardless of symptoms, to identify myocardial lesions (scars). (3) Results: Bidirectional MAL block was achieved in all patients. LGE-MRI imaging revealed scarring in 45 of 72 (63%) segments. In all three segments of MAL, ablation time and AI were significantly higher in scarred areas compared with non-scar areas. The mean AI value to detect a durable scar was 514.2 in S1, 486.7 in S2 and 485.9 in S3. The mean ablation time to detect a scar was 20.4 s in S1, 22.1 s in S2 and 20.2 s in S3. Mean contact force and impedance drop were not significantly different between scar and non-scar areas. (4) Conclusions: Targeting optimal AI values is crucial to determine persistent left atrial scars on an LGE-MRI scan 3 months after ablation. AI guided linear left atrial ablation seems to be effective in producing durable lesions.