Yeni H. Yücel

Dr. Yeni H. Yücel


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Photoacoustics
Verified
Journal Article
Open access
KCKirsten Cardinell
Kirsten Cardinell
NGNeeru Gupta
Neeru Gupta
BKBryan D. Koivisto
Bryan D. Koivisto
JKJ. Carl Kumaradas
J. Carl Kumaradas
XZXun Zhou
Xun Zhou
YYYeni H. Yücel
Yeni H. Yücel
In vivo near-infrared (NIR) photoacoustic imaging (PAI) studies using novel contrast agents require validation, often via fluorescence imaging. Bioconjugation of NIR dyes to proteins is a versatile platform to obtain contrast agents for specific biomedical applications. Nonfluorescent NIR dyes with higher photostability present advantages for quantitative PAI, compared to most fluorescent NIR dyes. However, they don’t provide a fluorescence signal required for fluorescence imaging. Here, we designed a hybrid PA-fluorescent contrast agent by conjugating albumin with a NIR nonfluorescent dye (QC-1) and a visible spectrum fluorescent dye, a BODIPY derivative. The new hybrid tracer QC-1/BSA/BODIPY (QBB) had a low minimum detectable concentration (2.5μM), a steep linear range (2.4–54.4 μM; slope 3.39 E -5), and high photostability. Tracer signal was measured in vivo using PAI to quantify its drainage from eye to the neck and its localization in the neck lymph node was validated with postmortem fluorescence imaging.

20 July 2023 in npj Microgravity
Verified
Journal Article
Open access
PDF file
CSClaudia Stern
Claudia Stern
YYYeni H. Yücel
Yeni H. Yücel
PEPeter zu Eulenburg
Peter zu Eulenburg
ATAnne Pavy-Le Traon
Anne Pavy-Le Traon
LPLonnie G Petersen
Lonnie G Petersen
Long-duration human spaceflight can lead to changes in both the eye and the brain, which have been referred to as Spaceflight Associated Neuro-ocular Syndrome (SANS). These changes may manifest as a constellation of symptoms, which can include optic disc edema, optic nerve sheath distension, choroidal folds, globe flattening, hyperopic shift, and cotton wool spots. Although the underpinning mechanisms for SANS are not yet known, contributors may include intracranial interstitial fluid accumulation following microgravity induced headward fluid shift. Development and validation of SANS countermeasures contribute to our understanding of etiology and accelerate new technology including exercise modalities, Lower Body Negative Pressure suits, venous thigh cuffs, and Impedance Threshold Devices. However, significant knowledge gaps remain including biomarkers, a full set of countermeasures and/or treatment regimes, and finally reliable ground based analogs to accelerate the research. This review from the European Space Agency SANS expert group summarizes past research and current knowledge on SANS, potential countermeasures, and key knowledge gaps, to further our understanding, prevention, and treatment of SANS both during human spaceflight and future extraterrestrial surface exploration.

2 November 2020 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
KSKieran Sharma
Kieran Sharma
MAMaryam Amin Mohammed Amin
Maryam Amin Mohammed Amin
NGNeeru Gupta
Neeru Gupta
LZLorne Zinman
Lorne Zinman
XZXun Zhou
Xun Zhou
YYYeni H. Yücel
Yeni H. Yücel
Purpose: To determine whether patients with amyotrophic lateral sclerosis (ALS) show retinal axon pathology. Methods: Postmortem eyes from 10 patients with ALS were sectioned and compared with 10 age-matched controls. Retinal sections were evaluated with periodic acid Schiff and phosphorylated (P-NF) and nonphosphorylated (NP-NF) forms of neurofilament with SMI 31 and 32 antibodies. Spheroids identified in the retinal nerve fiber layer were counted and their overall density was calculated in central, peripheral, and peripapillary regions. P-NF intensity was quantified. Morphometric features of ALS cases were compared with age-matched controls using the exact Wilcoxon matched-pairs signed-rank test. Results: Distinct periodic acid Schiff–positive round profiles were identified in the retinal nerve fiber layer of patients with ALS and were most commonly observed in the peripapillary and peripheral retina. The density of periodic acid Schiff–positive spheroids was significantly greater in patients with ALS compared with controls (P = 0.027), with increased density in the peripapillary region (P = 0.047). Spheroids positive for P-NF and NP-NF were detected. P-NF–positive spheroid density was significantly increased in patients with ALS (P = 0.004), while the density of NP-NF spheroids did not differ significantly between ALS and control groups (P > 0.05). P-NF immunoreactivity in the retinal nerve fiber layer was significantly greater in patients with ALS than in controls (P = 0.002). Conclusions: Retinal spheroids and axon pathology discovered in patients with ALS, similar to hallmark findings in spinal cord motor neurons, point to disrupted axon transport as a shared pathogenesis. Retinal manifestations detected in ALS suggest a novel biomarker detectable by noninvasive retinal imaging to help to diagnose and monitor ALS disease.

1 May 2020 in Experimental Eye Research
Verified
Journal Article
Open access
YYYeni H. Yücel
Yeni H. Yücel
FCFang Cheng
Fang Cheng
KCKirsten Cardinell
Kirsten Cardinell
XZXun Zhou
Xun Zhou
HIHyacinth Irving
Hyacinth Irving
NGNeeru Gupta
Neeru Gupta
We aim to determine whether lymphatic drainage from the eye changes with age. Using quantitative photoacoustic tomography, groups of young and older mice were studied in the live state. 10 CD-1 mice of 2-3 months (5M/5F) were studied in addition to 13 older mice of 12-13 months (6M/7F). In each of 23 mice, near-infrared tracer (a near-infrared dye, QC-1 conjugated with Bovine Serum Albumin) was injected into the right eye, and imaging of ipsilateral cervical lymph nodes was performed with laser pulses at 11 different wavelengths prior to and 20 min, 2, 4 and 6 h after injection. Mean pixel intensities (MPIs) of nodes were calculated at each imaging session. The areas under the curves (AUC) were calculated for both groups of mice and compared using the t-test. The slopes of MPI of each region of interest were compared using the linear mixed model before and after adjusting for sex, body weight and intraocular pressure of the right eye. The mean intraocular pressure of right eyes before injection was similar in older and younger groups (12.77 +/- 2.01 mmHg and 12.90 +/- 2.38 mmHg, respectively; p = 0.888). In each mouse, the photoacoustic signal was detected in the right cervical lymph nodes at the 2-h time point following tracer injection into the right eye. At the 4 and 6 h imaging times, a steady increase of tracer signal was observed. Areas under the curve in the right cervical nodes were decreased significantly in older mice compared to younger mice (p = 0.007). The slopes of MPI in the nodes were significantly decreased in old mice compared to young mice both before and after adjusting for sex, body weight and intraocular pressure of the right eye (p = 0.003). In conclusion, lymphatic drainage from the eye is significantly reduced in older eyes. This finding suggests that impaired lymphatic clearance of aqueous humor, proteins and antigens from the eye may contribute to age-related disease of the eye such as glaucoma and inflammatory eye disease.

9 September 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
HFHala F. Faragalla
Hala F. Faragalla
BDBahar Davoudi
Bahar Davoudi
NNNaama Nofech-Moses
Naama Nofech-Moses
YYYeni H. Yücel
Yeni H. Yücel
KJKiran Jakate
Kiran Jakate
Thorough gross examination of breast cancer specimens is critical in order to sample relevant portions for subsequent microscopic examination. This task would benefit from an imaging tool which permits targeted and accurate block selection. Optical coherence tomography (OCT) is a non-destructive imaging technique that visualizes tissue architecture and has the potential to be an adjunct at the gross bench. Our objectives were: (1) to familiarize pathologists with the appearance of breast tissue entities on OCT; and (2) to evaluate the yield and quality of OCT images of unprocessed, formalin-fixed breast specimens for the purpose of learning and establishment of an OCT–histopathology library. Methods: Firstly, 175 samples from 40 formalin-fixed, unprocessed breast specimens with residual tissue after final diagnosis were imaged with OCT and then processed into histology slides. Histology findings were correlated with features on OCT. Results: Residual malignancy was seen in 30% of tissue samples. Corresponding OCT images demonstrated that tumor can be differentiated from fibrous stroma, based on features such as irregular boundary, heterogeneous texture and reduced penetration depth. Ductal carcinoma in situ can be subtle, and it is made more recognizable by the presence of comedo necrosis and calcifications. OCT features of benign and malignant breast entities were compiled in a granular but user-friendly reference tool. Conclusion: OCT images of fixed breast tissue were of sufficient quality to reproduce features of breast entities previously described in fresh tissue specimens. Our findings support the use of readily available unprocessed, fixed breast specimens for the establishment of an OCT–histopathology library.

1 November 2025 in Eye and Brain
Verified
Journal Article
Open access
PDF file
AZArya Zarrinbakhsh
Arya Zarrinbakhsh
NGNeeru Gupta
Neeru Gupta
JSJessica Sinha
Jessica Sinha
XZXun Zhou
Xun Zhou
SCShuo Chen
Shuo Chen
YYYeni H. Yücel
Yeni H. Yücel
Purpose: Microgravity-induced headward fluid shifts are one of the mechanisms implicated in spaceflight-associated eye conditions, including intraocular pressure (IOP) and retinal nerve fiber layer (RNFL) thickness changes. In this longitudinal study, we investigated IOP and RNFL thickness changes over time in a mouse model of microgravity-induced headward fluid shifts. Methods: The study involved 20 adult male B6(Cg)-Tyrc− 2J/J mice, randomly assigned to two groups: the hindlimb unloading (HU) mice, unloaded for 21 days followed by 14 days of release, and control mice kept under the same conditions except HU for 35 days. IOP and RNFL thickness in peripapillary and peripheral rings of right and left eyes were measured before and once a week after HU. Our analysis utilized mixed linear models to compare the estimated marginal means of IOP and RNFL thickness on each day with baseline values for each eye. Post hoc splined mixed linear models with a knot at day 14 were employed to assess the rate of IOP change in each segment. Results: IOP was significantly elevated in both eyes of the HU mice on day 14 compared to baseline. The splined analysis revealed a bilateral positive rate of IOP change up to day 14, followed by a negative rate of change thereafter. In contrast, control mice displayed no significant differences in IOP at any timepoint. RNFL thicknesses of right eye peripapillary and peripheral rings were reduced after 1 week and 2 weeks, respectively. In contrast, left eye RNFL thickness measurements did not show any significant change compared to baseline. Conclusion: The HU mouse model displays a distinct ocular phenotype that may be useful for understanding IOP and RNFL changes in microgravity and their relevance to Spaceflight-Associated Neuro-ocular Syndrome.