Emeline Fresnel

Dr. Emeline Fresnel

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2018 in International Journal of Chronic Obstructive Pulmonary Disease
Verified
Journal Article
Open access
PDF file
SBSophie Blouet
Sophie Blouet
JSJasmine Sutter
Jasmine Sutter
EFEmeline Fresnel
Emeline Fresnel
AKAdrien Kerfourn
Adrien Kerfourn
ACAntoine Cuvelier
Antoine Cuvelier
MPMaxime Patout
Maxime Patout
Prediction of severe acute exacerbation using changes in breathing pattern of COPD patients on home noninvasive ventilation Sophie Blouet,1 Jasmine Sutter,1 Emeline Fresnel,2 Adrien Kerfourn,2 Antoine Cuvelier,1,3 Maxime Patout1,3 1Department of Pulmonary, Thoracic Oncology and Intensive Respiratory Care, Rouen University Hospital, Rouen, France; 2Kernel Biomedical, Rouen University Hospital, Bois-Guillaume, France; 3Normandie Univ, UNIRouen, EA3830-GRHV, Institute for Research and Innovation in Biomedicine, Rouen, France Introduction: Acute exacerbation of COPD (AECOPD) is associated with poor outcome. Noninvasive ventilation (NIV) is recommended to treat end-stage COPD. We hypothesized that changing breathing pattern of COPD patients on NIV could identify patients with severe AECOPD prior to admission. Methods: This is a prospective monocentric study including all patients with COPD treated with long-term home NIV. Patients were divided in two groups: a stable group in which patients were admitted for the usual respiratory review and an exacerbation group in which patients were admitted for inpatient care of severe AECOPD. Data from the ventilator were downloaded and analyzed over the course of the 10 days that preceded the admission. Results: A total of 62 patients were included: 41 (67%) in the stable group and 21 (33%) in the exacerbation group. Respiratory rate was higher in the exacerbation group than in the stable group over the 10 days preceding inclusion (18.2±0.5 vs 16.3±0.5 breaths/min, respectively) (P=0.034). For 2 consecutive days, a respiratory rate outside the interquartile limit of the respiratory rate calculated over the 4 preceding days was associated with an increased risk of severe AECOPD of 2.8 (95% CI: 1.4–5.5) (P1.0845 was associated with an increased risk of severe AECOPD of 4.0 (95% CI: 1.5–10.5) (P=0.001). This assessment had the sensitivity, specificity, positive predictive, and negative predictive values of 81.0, 63.4, 53.1, and 86.7%, respectively. Conclusion: Data from NIV can identify a change in breathing patterns that predicts severe AECOPD. Keywords: noninvasive ventilation, acute exacerbation of COPD, breathing pattern

26 July 2021 in Respirology
Verified
Journal Article
Closed access
PDF file
GJGrégoire Jolly
Grégoire Jolly
LRLéa Razakamanantsoa
Léa Razakamanantsoa
EFEmeline Fresnel
Emeline Fresnel
ZGZouhaier Gharsallaoui
Zouhaier Gharsallaoui
ACAntoine Cuvelier
Antoine Cuvelier
MPMaxime Patout
Maxime Patout

19 August 2014 in EPJ Nonlinear Biomedical Physics
Verified
Journal Article
Open access
PDF file
EFEmeline Fresnel
Emeline Fresnel
JMJean-François Muir
Jean-François Muir
CLChristophe Letellier
Christophe Letellier
An important issue in noninvasive mechanical ventilation consists in understanding the origins of patient-ventilator asynchrony for reducing their incidence by adjusting ventilator settings to the intrinsic ventilatory dynamics of each patient. One of the possible ways for doing this is to evaluate the performances of the domiciliary mechanical ventilators using a test bench. Such a procedure requires to model the evolution of the pressure imposed by respiratory muscles, but for which there is no standard recommendations.

30 November 2022 in Healthcare
Verified
Journal Article
Open access
PDF file
LMLebret Marius
Lebret Marius
EFEmeline Fresnel
Emeline Fresnel
NPNathan Prouvez
Nathan Prouvez
KZKaixian Zhu
Kaixian Zhu
AKAdrien Kerfourn
Adrien Kerfourn
MPMaxime Patout
Maxime Patout
Background: The impact of leaks has mainly been assessed in bench models using continuous leak patterns which did not reflect real-life leakage. We aimed to assess the impact of the pattern and intensity of unintentional leakage (UL) using several respiratory models. Methods: An active artificial lung (ASL 5000) was connected to three bilevel-ventilators set in pressure mode; the experiments were carried out with three lung mechanics (COPD, OHS and NMD) with and without upper airway obstruction. Triggering delay, work of breathing, pressure rise time, inspiratory pressure, tidal volume, cycling delay and the asynchrony index were measured at 0, 6, 24 and 36 L/min of UL. We generated continuous and inspiratory UL. Results: Compared to 0 L/min of UL, triggering delays were significantly higher with 36 L/min of UL (+27 ms) and pressure rise times were longer (+71 ms). Cycling delays increased from −4 [−250–169] ms to 150 [−173–207] ms at, respectively 0 L/min and 36 L/min of UL and work of breathing increased from 0.15 [0.12–0.29] J/L to 0.19 [0.16–0.36] J/L. Inspiratory leakage pattern significantly increased triggering delays (+35 ms) and cycling delays (+263 ms) but decreased delivered pressure (−0.94 cmH2O) compared to continuous leakage pattern. Simulated upper airway obstruction significantly increased triggering delay (+199 ms), cycling delays (+371 ms), and decreased tidal volume (−407 mL) and pressure rise times (−56 ms). Conclusions: The pattern of leakage impacted more the device performances than the magnitude of the leakage per se. Flow limitation negatively reduced all ventilator performances.

Verified
Journal Article
Open access
PDF file
TBTristan Bonnevie
Tristan Bonnevie
FGFrancis-Edouard Gravier
Francis-Edouard Gravier
EFEmeline Fresnel
Emeline Fresnel
AKAdrien Kerfourn
Adrien Kerfourn
Clement MedrinalClement Medrinal
Clement Medrinal
CVCatherine Viacroze
Catherine Viacroze
Noninvasive ventilation (NIV) during exercise has been suggested to sustain higher training intensity but the type of NIV interface, patient-ventilator asynchronies (PVA) or technological limitation of the ventilator may interfere with exercise. We assessed whether these parameters affect endurance exercise capacity in severe COPD patients. In total, 21 patients with severe COPD not eligible to home NIV performed three constant workload tests. The first test was carried out on spontaneous breathing (SB) and the following ones with NIV and a nasal or oronasal mask in a randomized order. PVA and indicators of ventilator performance were assessed through a comprehensive analysis of the flow pressure tracing raw data from the ventilator. The time limit was significantly reduced with both masks (406 s (197–666), 240 s (131–385) and 189 s (115–545), p < 0.01 for tests in SB, with oronasal and nasal mask, respectively). There were few PVA with an oronasal mask (median: 3.4% (1.7–5.2)) but the ventilator reached its maximal generating capacity (median flowmax: 208.0 L/s (189.5–224.8) while inspiratory pressure dropped throughout exercise (from 10.1 (9.4–11.4) to 8.8 cmH2O (8.6–10.8), p < 0.01). PVA were more frequent with nasal mask (median: 12.8% (3.2–31.6), p < 0.01). Particularly, the proportion of patients with ineffective efforts > 10% was significantly higher with nasal interface (0% versus 33.3%, p < 0.01). NIV did not effectively improve endurance capacity in COPD patients not acclimated to home NIV. This was due to a technological limitation of the ventilator for the oronasal mask and the consequence either of an insufficient pressure support or a technological limitation for the nasal mask.

27 January 2022 in European Respiratory Journal
Verified
Journal Article
Open access
PDF file
CRClaudio Rabec
Claudio Rabec
EFEmeline Fresnel
Emeline Fresnel
YRYann Rétory
Yann Rétory
KZKaixian Zhu
Kaixian Zhu
KJKarima Joly
Karima Joly
MPMaxime Patout
Maxime Patout
464 Objectives With respect to the broad application of [18F-methyl]fluorocholine(FCH)and its ungoing process of marketing authorisation, there is a need for a safe, but also efficient and convenient way of routine quality control of FCH since no monograph is currently available for radiolabelled choline derivatives. Therefore, a GC- method should be developed and validated which allows the simultaneous quantitation of all chemical impurities and residual solvents as acetonitrile, ethanol, dibromomethane and DMAE. Methods Analytical GC has been performed with a GC-capillary column Optima 1701 (50 m x 0.32 mm) and a deactivated capillary pre-column phenyl-Sil (10 m x 0.32) in row with a flame ionisation detector (FID. The validation includes the following tests: specificity, range, accuracy, linearity, precision, limit of detection (LOD) and limit of quantification (LOQ) of all listed substances. Results The described GC-method has been successfully used for the quantitation of the listed chemical impurities. The specificity of the GC-separation has been proved by demonstrating that the appearing peaks are completely separated from each other and a resolution R ≥ 1,5 for the separation of the peaks could be achieved. The specified range derived from linearity studies confirmed that the analytical procedure provides an acceptable degree of linearity, accuracy and precision when applied to samples containing amounts of analyte within the specified range. For each substance a range from the LOD until 110-120 % of the specification limit could be demonstrated. The LOD and LOQ were determined and both values were much lower than the specification limit for all substances: ethanol (17.6 µg/ 61.6 µg), DMAE (1.7 µg/ 5.1 µg), acetonitrile (19.6 µg/ 63.4 µg)and dibromomethane (2.4 µg/ 7.1 µg). Conclusions An efficient and convenient GC-method for the quality control of FCH has been developed and validated meeting all acceptance criteria in terms of linearity, specificity, precision, accuracy as well as LOD and LOQ