Frederic HEIM

Prof. Frederic HEIM


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2015 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
FKFoued Khoffi
Foued Khoffi
FHFrederic HEIM
Frederic HEIM

1 June 2015 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
FBF. Bodin
F. Bodin
CJC. Jung
C. Jung
FDF. Dieval
F. Dieval
NCN. Chakfe
N. Chakfe
SWS. Wisniewski
S. Wisniewski
FHFrederic HEIM
Frederic HEIM

31 January 2011 in Materials and Manufacturing Processes
Verified
Journal Article
Closed access
CMCoralie Marchand
Coralie Marchand
FHFrederic HEIM
Frederic HEIM
BDBernard Durand
Bernard Durand
NCNabil Chafke
Nabil Chafke
Percutaneous aortic valve implantation has become an alternative technique to surgical valve replacement in patients with high risk for open chest surgery. NiTi vascular stents clinically used today for noninvasive aortic valve replacement are, however, too traumatic. Obtained from laser cut Nitinol material, these stents impede the dimensional changes of the compliant aortic root over the cardiac cycle. Stents braided from Nitinol wire are conversely more flexible and appear to be a less traumatic alternative for heart valve replacement. However, in order to keep the cohesion of the braid specific 3D design, and the radial flexibility of the stent, the Nitinol wire needs to undergo successive thermal treatments for shape setting purpose. This study investigates the effect of two successive and nonidentical heat treatments on constrained stent wire behavior, in terms of microstructure and mechanical properties. With a first heat treatment over 10 minutes time at 450°on a fixture plate A F could be increased to handle easily the martensitic malleable stent material at ambient temperature. A second treatment over 10 min time at 550°decreased A F to 0°C to get a very elastic austenitic structure made with interlaced wires able to undergo 20% dimensional variations.

1 October 2019 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
HJHiba Jaziri
Hiba Jaziri
SMSofiene Mokhtar
Sofiene Mokhtar
NCNabil Chakfe
Nabil Chakfe
FHFrederic HEIM
Frederic HEIM
SASaber Ben Abdessalem
Saber Ben Abdessalem

1 December 2014 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
AVAntoine Vaesken
Antoine Vaesken
FHFrederic HEIM
Frederic HEIM
NCNabil Chakfe
Nabil Chakfe

29 November 2014 in Journal of Biomedical Materials Research Part B: Applied Biomaterials
Verified
Journal Article
Closed access
PDF file
FKFoued Khoffi
Foued Khoffi
FHFrederic HEIM
Frederic HEIM
NCNabil Chakfe
Nabil Chakfe
JLJason T. Lee
Jason T. Lee