Qi Guo

Prof. Qi Guo

Beijing Clover Tech Ltd., Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 November 2022 in Toxins
Verified
Journal Article
Open access
PDF file
SLSunlin Luo
Sunlin Luo
YLYing Liu
Ying Liu
QGQi Guo
Qi Guo
Xiong WangXiong Wang
Xiong Wang
YTYing Tian
Ying Tian
Yiqiang ChenYiqiang Chen
Yiqiang Chen
In this study, a gas chromatography–mass spectrometry (GC-MS) method was established for the determination of zearalenone and its five derivatives in feed, including zearalanone, α-zearalanol, β-zearalanol, α-zearalenol, and β-zearalenol. An effective immunoaffinity column was prepared for sample purification, which was followed by the silane derivatization of the eluate after an immunoaffinity chromatography analysis for target compounds by GC-MS. Matrix effects were corrected by an isotope internal standard of zearalenone in this method. The six analytes had a good linear relationship in the range of 2–500 ng/mL, and the correlation coefficients were all greater than 0.99. The limits of detection (LODs) and limits of quantification (LOQs) were less than 1.5 μg/kg and 5.0 μg/kg, respectively. The average spike recoveries for the six feed matrices ranged from 89.6% to 112.3% with relative standard deviations (RSDs) less than 12.6%. Twenty actual feed samples were analyzed using the established method, and at least one target was detected. The established GC-MS method was proven to be reliable and suitable for the determination of zearalenone and its derivatives in feed.

11 September 2022 in Toxins
Verified
Journal Article
Open access
PDF file
YLYing Liu
Ying Liu
YJYongpeng Jin
Yongpeng Jin
QGQi Guo
Qi Guo
Xiong WangXiong Wang
Xiong Wang
SLSunlin Luo
Sunlin Luo
Yiqiang ChenYiqiang Chen
Yiqiang Chen
In this study, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for simultaneous determination of deoxynivalenol, aflatoxin B1, zearalenone, ochratoxin A, T-2 toxin and fumonisin B1 in feed and feedstuff was established. The sample was extracted with an acetonitrile–water mixture (60:40, v/v), purified by an immunoaffinity column, eluted with a methanol–acetic acid mixture (98:2, v/v), and reconstituted with a methanol–water mixture (50:50, v/v) after drying with nitrogen. Finally, the reconstituted solution was detected by LC-MS/MS and quantified by isotope internal standard method. The six mycotoxins had a good linear relationship in a certain concentration range, the correlation coefficients were all greater than 0.99, the limits of detection were between 0.075 and 1.5 µg·kg−1, and the limits of quantification were between 0.5 and 5 µg·kg−1. The average spike recoveries in the four feed matrices ranged from 84.2% to 117.1% with relative standard deviations less than 11.6%. Thirty-six actual feed samples were analyzed for mycotoxins, and at least one mycotoxin was detected in each sample. The proposed method is reliable and suitable for detecting common mycotoxins in feed samples.