Currently, fuel consumption in the Antarctica Showa Base has been increasing along with research, observation activities and comfort of the base. Considering the limited capacity of the ship Shirase in charge of transporting fuel to the base, there is a need to ensure a sustainable provision of energy to the base by introducing renewable energy. In this study, aiming at the reduction of fuel consumption, considered the operation of the microgrid to introduce a decentralized installation of the engine generator, renewable energy, seawater source heat pump, electric thermal storage heater and a seasonal energy shift using the organic hydride to the base. As a result of the analysis, by introducing a Seasonal energy shift using an organic hydride, it was confirmed that the improved effect of reducing winter fuel consumption.
Background: To assess the changes in the inclination of the premolar and molar during a maxillary expansion with a micro-implant-assisted skeletal expander (MSE). Materials and Methods: A total of 21 patients (16 females, 5 males) with a mean age of 18.6 ± 4.5 (range 11.3–26.3 years) with a transverse maxillary deficiency were included in this study. They all received an MSE appliance for the maxillary skeletal expansion. The activation protocol consisted of about 0.5 mm expansion a day until a diastema was observed and continued with about 0.25 mm a day until the desired transverse relationship between the maxilla and mandible was achieved. OnDemand3D software was used for the measurements of the inclination change in the maxillary premolars and molars, pre- and post-expansion. Graphpad was used to compare the mean change in each tooth with the zero value (no change), and the p values of these changes with every tooth were calculated. Moreover, the changes and the mean values of all the teeth on the left and right sides were calculated separately. Results: A total of sixteen measurements were conducted for each patient. The first premolars tipped palatally after the expansion, while the second premolars and molars tipped buccally. The changes were significant for the molars and the left second premolar. Conclusions: The MSE induced some changes in the tooth inclination. The first premolars moved palatally, most likely due to perioral musculature and mastication force, while the first and second molars moved buccally. The second molar buccal movement is most likely due to the craniofacial rotation caused by the MSE as they were not subject to the expansion force.
Background: Temporary anchorage devices (TADs) are broadly used in orthodontic treatment. TADs must be placed accurately to avoid collision against tooth roots. To place miniscrews with a higher accuracy, a digitally designed surgical guide was proposed in previous studies. However, to our knowledge, there have been no articles that have assessed the minimal required length to achieve good drilling accuracy. The objective of the present study was to evaluate the accuracy of pre-drilling using computer-aided designed surgical guides with different lengths. Methods: A typodont model was scanned, and surgical guides of 3.0, 4.5, and 6.0 mm were designed. Duplicated typodonts and the surgical guides were printed with a 3D printer. Using these models and surgical guides, pre-drillings were performed. Freehand drilling was also conducted for the control. The drilled models were scanned with micro-computed tomography to evaluate the accuracy. Results: The mean errors at the tip of the drill were 0.44 mm, 0.61 mm, 0.41 mm, and 0.24 mm for the freehand drilling, and 3.0, 4.5, and 6.0 mm for the surgical guide, respectively. Conclusion: The results suggested that a longer surgical guide was recommended to achieve good insertion accuracy for a narrow interradicular space, and that 3.0 mm was enough when an error of 1.0 mm was acceptable for the insertion site.
Background: This study aimed to evaluate the effect of external force applied from mini-screws to the aligner during space closure in extraction cases, and to determine the optimal loading conditions to prevent lingual crown tipping of the incisor and mesial tipping of the molar using the finite element (FE) method. Methodology: A three-dimensional FE model of the maxillary dentition with extraction of first premolars was constructed, and three different loading conditions were designed. The aligner was activated for 0.25 mm of incisor retraction without using mini-screws, with application of 0, 100, 200, or 300 cN of distal force through mini-screws placed in the posterior region, or with application of 0, 100, 200, 300, or 400 cN of intrusive force through mini-screws placed in the anterior region, in addition to the application of 300 cN of distal force. Results: As the magnitude of distal force increased, the degree of mesial tipping of the first molar gradually decreased, becoming almost zero with nearly 300 cN of distal force. As the magnitude of intrusive force increased in addition to the application of 300 cN of distal force, the degree of lingual crown tipping of the central incisor gradually decreased, becoming almost zero with nearly 400 cN of intrusive force. Conclusion: Application of 300 cN of distal force to the aligner from mini-screws placed in the posterior region could completely prevent mesial tipping of the molar and anchorage loss during anterior retraction. Application of 400 cN of intrusive force from mini-screws placed in the anterior region could prevent lingual crown tipping of the incisor, thus providing better torque control for the incisors.