Syed Agha Shah Ali

Mr. Syed Agha Shah Ali

Civil Engineering, National University of Sciences & Technology, Islamabad, Islāmābād, Pakistan
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 February 2023 in Polymers
Verified
Journal Article
Open access
PDF file
NANisma Agha
Nisma Agha
Arshad HussainArshad Hussain
Arshad Hussain
SASyed Agha Shah Ali
Syed Agha Shah Ali
YQYanjun Qiu
Yanjun Qiu
This study evaluates the performance of Polyethylene Terephthalate (PET)-modified hot mix asphalt. Aggregate, bitumen of grade 60/70 and crushed plastic bottle waste were utilized in this study. Polymer Modified Bitumen (PMB) was prepared using a high shear laboratory type mixer rotating at a speed of 1100 rpm with varying PET content of 2%, 4%, 6%, 8% and 10%, respectively. Overall, the results of preliminary tests suggested that bitumen hardened with the addition of PET. Following optimum bitumen content determination, various modified and controlled HMA samples were prepared as per wet and dry mixing techniques. This research presents an innovative technique to compare the performance of HMA prepared via dry and wet mixing techniques. Performance evaluation tests, which include the Moisture Susceptibility Test (ALDOT-361-88), Indirect Tensile Fatigue Test (ITFT-EN12697-24) and Marshall Stability and Flow Tests (AASHTO T245-90), were conducted on controlled and modified HMA samples. The dry mixing technique yielded better results in terms of resistance against fatigue cracking, stability and flow; however, the wet mixing technique yielded better results in terms of resistance against moisture damage. The addition of PET at more than 4% resulted in a decreased trend for fatigue, stability and flow due to the stiffer nature of PET. However, for the moisture susceptibility test optimum PET content was noted to be 6%. Polyethylene Terephthalate-modified HMA is found to be the economical solution for high volume road construction and maintenance, besides having other significant advantages such as increased sustainability and waste reduction.

10 October 2022 in Buildings
Verified
Journal Article
Open access
PDF file
NNNaqeeb Nawaz
Naqeeb Nawaz
SASyed Agha Shah Ali
Syed Agha Shah Ali
SJSYED TASEER ABBAS JAFFAR
SYED TASEER ABBAS JAFFAR
TJTurab H. Jafri
Turab H. Jafri
TOTae-Min Oh
Tae-Min Oh
MAMarc Azab
Marc Azab
This study presents a cost-based optimization model for the design of isolated foundations in cohesive soils. The optimization algorithm not only incorporates safety requirements in the form of ultimate limit state (ULS) and serviceability limit state (SLS) criteria but also deals with the economics simultaneously. In that regard, the generalized reduced gradient (GRG) method is used for the optimization purpose to achieve the least construction cost of an isolated foundation along with the integration of design parameters as optimization variables. The optimization technique is elaborated using a design example in silty clayey soil and the results of the optimized design are compared with those of the conventional design. The optimization model shows that the optimized design can reduce the construction cost by up to 44% as compared to the conventional design cost for the particular example. Moreover, a sensitivity analysis is also performed to evaluate the quantitative impact of cohesive soil properties, design load, and groundwater table on the construction cost. The results indicate that the construction cost majorly depends on the combined effect of four key parameters: Young’s modulus, recompression index, design load, and groundwater table.