Background: Bivalirudin was widely used as an anticoagulant during coronary interventional procedure in western countries. However, it was not available in China before this clinical trial was designed. This randomized, single-blind and multicenter clinical trial aimed to evaluate the efficacy and the safety of domestic bivalirudin during percutaneous coronary intervention (PCI). Methods: A randomized, single-blind, multicenter trial was designed. Elective PCI candidates in five centers were randomized into a bivalirudin group and a heparin group, which were treated with domestic bivalirudin and non-fractional heparin during the PCI procedure. The efficacy was evaluated by comparing the activated coagulation time (ACT), the procedural success rate (residual stenosis 0.05). Survival rates without major adverse cardiac events at 30 days after PCI were 100.0% in the bivalirudin group and 98.2% in the heparin group (P>0.05). Mild bleeding rates were 0.9% and 6.9% (P<0.05) at 24 hours, and 1.9% and 8.8% (P<0.05) at 30 days after PCI in the bivalirudin group and heparin group respectively. There was one severe gastrointestinal bleeding case in the heparin group. Conclusions: Domestic bivalirudin is an effective and safe anticoagulant during elective PCI procedures. The efficacy is not inferior to heparin, but the safety is superior to heparin.
30 March 2021 in Journal of Cardiovascular Electrophysiology
Background: High-power radiofrequency (RF) catheter ablation was considered as a promising alternative strategy to conventional-power ablation in the treatment of patients with atrial fibrillation (AF). This study sought to compare the efficacy and safety of high-power energy delivery to that of conventional-power setting in AF catheter ablation.Methods: We performed a systematic review of relevant literature in Pubmed, Embase, Cochrane library, and Google Scholar database. Sixteen eligible studies totaling 3,307 patients (1,929 for high-power ablation; 1,378 for conventional-power ablation) met inclusion criteria.Results: During a median 12 month follow-up, high-power ablation showed a significantly higher AF/atrial tachycardia-free survival rate in comparison with conventional-power ablation (risk ratio [RR] 1.09, 95% CI 1.02 to 1.15, p = 0.008). Notably, a high-power strategy convincingly decreased the procedure time (weighted mean difference [WMD] −46.11 min, 95% CI −59.15 to −33.07, p < 0.001) and RF ablation time (WMD −19.19 min, 95% CI −24.47 to −13.90, p < 0.001), along with reduced fluoroscopy time (WMD −7.82 min, 95% CI −15.13 to −0.68, p = 0.036). In addition, there was no perceptible difference in the potential risk of procedure-related complications between these two approaches (RR 0.81, 95% CI 0.48 to 1.37, p = 0.428).Conclusions: High-power RF catheter ablation was associated with an improvement in long-term sinus rhythm maintenance for treatment of AF, without exacerbating the risk of adverse events during the procedure. Impressively, high-power pulmonary vein isolation had the potential to shorten the application duration and minimize fluoroscopic exposure.