Shiwu Liao

Mr. Shiwu Liao

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2017 in Applied Energy
Verified
Journal Article
Closed access
SLShiwu Liao
Shiwu Liao
Wei YaoWei Yao
Wei Yao
XHXingning Han
Xingning Han
JWJinyu Wen
Jinyu Wen
SCShijie Cheng
Shijie Cheng

1 March 2019 in Applied Energy
Verified
Journal Article
Closed access
XHXingning Han
Xingning Han
XCXinyu Chen
Xinyu Chen
MMMichael B. McElroy
Michael B. McElroy
SLShiwu Liao
Shiwu Liao
CNChris P. Nielsen
Chris P. Nielsen
JWJinyu Wen
Jinyu Wen

1 September 2019 in Applied Energy
Verified
Journal Article
Closed access
SLShiwu Liao
Shiwu Liao
Wei YaoWei Yao
Wei Yao
XHXingning Han
Xingning Han
JFJiakun Fang
Jiakun Fang
XAXiaomeng Ai
Xiaomeng Ai
HHHaibo He
Haibo He

2 April 2017 in Energies
Verified
Journal Article
Open access
PDF file
XHXingning Han
Xingning Han
SLShiwu Liao
Shiwu Liao
XAXiaomeng Ai
Xiaomeng Ai
Wei YaoWei Yao
Wei Yao
JWJinyu Wen
Jinyu Wen
The increasing penetration of renewable generation increases the need for flexibility to accommodate for growing uncertainties. The level of flexibility is measured by the available power that can be provided by flexible resources, such as dispatachable generators, in a certain time period under the constraint of transmission capacity. In addition to conventional flexible resources, energy storage is also expected as a supplementary flexible resource for variability accommodation. To aid the cost-effective planning of energy storage in power grids with intensive renewable generation, this study proposed an approach to determine the minimal requirement of power capacity and the appropriate location for the energy storage. In the proposed approach, the variation of renewable generation is limited within uncertainty sets, then a linear model is proposed for dispatchable generators and candidate energy storage to accommodate the variation in renewable generation under the power balance and transmission network constraints. The target of the proposed approach is to minimize the total power capacity of candidate energy storage facilities when the availability of existing flexible resources is maximized. After that, the robust linear optimization method is employed to convert and solve the proposed model with uncertainties. Case studies are carried out in a modified Garver 6-bus system and the Liaoning provincial power system in China. Simulation results well demonstrate the proposed optimization can provide the optimal location of energy storage with small power capacities. The minimal power capacity of allocated energy storage obtained from the proposed approach only accounts for 1/30 of the capacity of the particular transmission line that is required for network expansion. Besides being adopted for energy storage planning, the proposed approach can also be a potential tool for identifying the sufficiency of flexibility when a priority is given to renewable generation.


20 March 2017 in Energies
Verified
Journal Article
Open access
PDF file
SLShiwu Liao
Shiwu Liao
Wei YaoWei Yao
Wei Yao
XAXiaomeng Ai
Xiaomeng Ai
JWJinyu Wen
Jinyu Wen
QLQing Liu
Qing Liu
JTJingzhe Tu
Jingzhe Tu
The multi-infeed effective short-circuit ratio (MESCR) is widely used in indicating the strength of multi-infeed AC/DC power systems. However, when the widely used MESCR was adopted to evaluate the stability margin of the Eastern China Grid including three infeed ultra-high-voltage DC (UHVDC) and five high-voltage DC transmission lines in 2016, the MESCR result indicated the system was strong enough but in fact occasionally collapses after the N-1 contingency. To determine the reason for this conflict, this paper theoretically analyzes the limitations of the existing MESCR. The theoretical analysis reveals that when a large amount of capacitor compensations are concentratively installed in the system, the conventional MESCR will not be able to reflect the capacitor compensations’ influence on the system stability, and no matter how many capacitors are installed or where the capacitors are installed, the MESCR almost retains the same value; namely, the MESCR is saturated in such systems. To address the saturation problem of conventional MESCR, this paper proposes an improved multi-infeed effective short-circuit ratio (IMESCR) which considers the influences of all capacitor compensations by converting all capacitors installed throughout the system to virtual capacitors at the DC inverter station. Case studies are carried out based on the New England 39-bus system and the Eastern China Grid, respectively. The simulation results verify the theoretical analysis of the MESCR’s limitations in evaluating the stability of power systems with massive capacitors installed, and proves that the proposed IMESCR could accurately indicate the strength of AC/DC power systems. Therefore, the proposed IMESCR provides a new index for evaluating the stability margin of power systems with massive capacitor compensations installed.