Aline Mendes Gerage

Dr. Aline Mendes Gerage

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2013 in Journal of Strength & Conditioning Research
Verified
Journal Article
Closed access
MNMatheus Amarante Nascimento
Matheus Amarante Nascimento
RJRenata Selvatici Borges Januário
Renata Selvatici Borges Januário
AGAline Mendes Gerage
Aline Mendes Gerage
JMJerry L. Mayhew
Jerry L. Mayhew
FPFábio Luiz Cheche Pina
Fábio Luiz Cheche Pina
EDILSON S. CYRINOEDILSON S. CYRINO
EDILSON S. CYRINO
Refore should be precisely assessed. The purpose of this study was to analyze the number of testing sessions required to achieve consistent 1 repetition maximum (1RM) strength measurements in untrained older women. Forty-five untrained older women were measured for 1RM in bench press machine (BP), leg extension (LE) machine, and free weight arm curl (AC). Reliability coefficients for trials 1 and 2 for BP (intraclass correlation coefficient [ICC] = 0.973) and LE (ICC = 0.976) were higher than for AC (ICC = 0.953). Percent change from trial 1 to 2 for BP (3.5 ± 10.9%) and AC (3.8 ± 8.1%) was less than for LE (5.4 ± 6.2%), but all were significant increases between trials (p < 0.05). Trial differences were reduced to nonsignificant levels (p > 0.05) in the third trial for BP (0.0 ± 0.0%), LE (1.2 ± 3.0%) and AC (2.7 ± 5.9%). Reliability coefficients rose for BP and LE (ICC = 0.999) and AC (ICC = 0.963) when a third trial was performed. Bland and Altman plotting showed very small bias and limits of agreement (LoA) for both the exercises (BP: bias = 0 kg, limits of agreement = 0 kg; LE: bias = −0.16 kg, LoA = 2.21 kg; AC: bias = −0.11 kg, LoA = 1.72 kg). This approach to determine 1RM strength values produced rapid lifting technique familiarization resulting in a need of 2 to 3 test sessions to achieve consistent 1RM measurements in untrained older women....

7 October 2012 in European Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
AAAndreo Fernando Aguiar
Andreo Fernando Aguiar
RJRenata Selvatici Borges Januário
Renata Selvatici Borges Januário
RJRaymundo Pires Junior
Raymundo Pires Junior
AGAline Mendes Gerage
Aline Mendes Gerage
FPFábio Luiz Cheche Pina
Fábio Luiz Cheche Pina
EDILSON S. CYRINOEDILSON S. CYRINO
EDILSON S. CYRINO

1 January 2009 in Arquivos Brasileiros de Cardiologia
Verified
Journal Article
Open access
PDF file
Diego ChristofaroDiego Christofaro
Diego Christofaro
RFRômulo Araújo Fernandes
Rômulo Araújo Fernandes
AGAline Mendes Gerage
Aline Mendes Gerage
MAMarcelo José Alves
Marcelo José Alves
MPMarcos Doederlein Polito
Marcos Doederlein Polito
AOArli Ramos de Oliveira
Arli Ramos de Oliveira
Accurate blood pressure measurement is fundamental for scientific investigation or clinical decision-making. In this sense, it is important to verify the values provided by electronic devices. To validate the Omron HEM 742 blood pressure monitoring device in adolescents according to criteria suggested by the British Hypertension Society. A total of 150 adolescents aged between 10 and 16 years participated in the study. The automated Omron HEM 742 monitor was connected in Y to the mercury column auscultatory device, then three simultaneous measurements were taken, and the differences between the readings of the two devices were calculated. The intraclass correlation coefficient and Bland-Altman plot (agreement) were used to verify the relationship between both devices. Specificity and sensitivity of the device were determined by using the ROC curve. The comparison between the measurements showed an equal to or lower than 5mmHg difference in 67.3% of the systolic values, and 69.3% of the diastolic values; an equal to or lower than 10mmHg difference occurred in 87.3% and 90.6% of the systolic and diastolic values, respectively; an equal to or lower than 15mmHg difference was found in 96.6% of the systolic values and 97.3% of the diastolic values. These findings are consistent with a grade A according to the British Hypertension Society protocol. A marked consonance was observed between the values obtained by the automated monitor and this device was proven to be capable of identifying the presence or absence of high blood pressure. The Omron HEM 742 monitor was proved valid for blood pressure measurement in adolescents according to the criteria suggested by the British Hypertension Society.

4 March 2013 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
AGAline Mendes Gerage
Aline Mendes Gerage
CFClaudia L. M. Forjaz
Claudia L. M. Forjaz
MNM. A. Nascimento
M. A. Nascimento
RJR.S. B. Januário
R.S. B. Januário
MPM. D. Polito
M. D. Polito
EDILSON S. CYRINOEDILSON S. CYRINO
EDILSON S. CYRINO
The purpose of this study was to investigate the effect of resistance training on resting blood pressure and heart rate variability in elderly postmenopausal women. 29 untrained, non-hypertensive elderly women were randomly assigned to 2 groups: an intervention group (n=15, 65.5±5.0 years, 57.3±6.5 kg, 156.7±5.1 cm) that underwent a supervised resistance training program (8 exercises, 2 sets, 10–15 repetitions, 3 times/week) or a control group (n=14, 66.2±4.1 years, 61.1±11.7 kg, 157.5±7.1 cm) that participated in a supervised stretching program (25–30 min/session, 2 times/week). Resting auscultatory blood pressure, heart rate variability, evaluated from short recordings in a seated position, and maximal dynamic strength (1-RM test) were measured at baseline and after 12 weeks. A group x time ANOVA revealed that muscular strength increased significantly in the resistance training group (+ 10.2% for bench press and +12.7% for leg extension, P<0.05). Systolic blood pressure was reduced significantly in the resistance training group from pre- to post-intervention period (− 5 mmHg; P<0.05), while no significant effect was noted for diastolic blood pressure and heart rate variability indexes (P>0.05). None of these variables changed in the control group throughout the study. In conclusion, a supervised resistance training program improved muscular strength and reduced systolic blood pressure without affecting diastolic blood pressure and heart rate variability in elderly postmenopausal women.

30 December 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
AGAline Mendes Gerage
Aline Mendes Gerage
TBTania R. B. Benedetti
Tania R. B. Benedetti
BFBreno Q. Farah
Breno Q. Farah
FSFábio da S. Santana
Fábio da S. Santana
David OharaDavid Ohara
David Ohara
RRRaphael Ritti-Dias
Raphael Ritti-Dias
Physical activity is recommended as a part of a comprehensive lifestyle approach in the treatment of hypertension, but there is a lack of data about the relationship between different intensities of physical activity and cardiovascular parameters in hypertensive patients. The purpose of this study was to investigate the association between the time spent in physical activities of different intensities and blood pressure levels, arterial stiffness and autonomic modulation in hypertensive patients. In this cross-sectional study, 87 hypertensive patients (57.5 ± 9.9 years of age) had their physical activity assessed over a 7 day period using an accelerometer and the time spent in sedentary activities, light physical activities, moderate physical activities and moderate-to-vigorous physical activities was obtained. The primary outcomes were brachial and central blood pressure. Arterial stiffness parameters (augmentation index and pulse wave velocity) and cardiac autonomic modulation (sympathetic and parasympathetic modulation in the heart) were also obtained as secondary outcomes. Sedentary activities and light physical activities were positively and inversely associated, respectively, with brachial systolic (r = 0.56; P < 0.01), central systolic (r = 0.51; P < 0.05), brachial diastolic (r = 0.45; P < 0.01) and central diastolic (r = 0.42; P < 0.05) blood pressures, after adjustment for sex, age, trunk fat, number of antihypertensive drugs, accelerometer wear time and moderate-to-vigorous physical activities. Arterial stiffness parameters and cardiac autonomic modulation were not associated with the time spent in sedentary activities and in light physical activities (P > 0.05). Lower time spent in sedentary activities and higher time spent in light physical activities are associated with lower blood pressure, without affecting arterial stiffness and cardiac autonomic modulation in hypertensive patients.

20 February 2017 in International Journal of Sports Medicine
Verified
Journal Article
Closed access
PDF file
CTCrisieli Tomeleri
Crisieli Tomeleri
AMAlexandre J. Marcori
Alexandre J. Marcori
ARAlex Silva Ribeiro
Alex Silva Ribeiro
AGAline Mendes Gerage
Aline Mendes Gerage
CPCamila de Souza Padilha
Camila de Souza Padilha
EDILSON S. CYRINOEDILSON S. CYRINO
EDILSON S. CYRINO
This study analyzed the effects of 12 weeks of resistance training (RT) on resting blood pressure (BP) and plasma levels of nitric oxide metabolites (NOx) in pre- and hypertensive older women, and evaluated the relationship between these 2 parameters. Thirty-five older women (68.2±5.7 years, 70.0±14.4 kg, 157.1±6.4 cm, 28.3±5.0 kg.m−2) were randomly allocated into a training group (TG; n=17), which performed a 12-week RT program, and a control group (CG; n=18), which did not perform any physical exercise. Anthropometry, one repetition maximum (1RM), body composition analysis by dual energy X-ray absorptiometry, blood samples, and resting BP were measured. There was a significant interaction for all variables analyzed, in which reductions of systolic BP (−8.5%), diastolic BP (−8.4%), and mean arterial pressure (−8.5%), and increases of NOx (+35.2%) were observed only for the TG. Moreover, a negative and significant correlation was observed (P<0.05; r=−0.63) between NOx and systolic BP in the TG. Results suggest that a 12-week RT program is sufficient to induce reductions in BP in pre- and hypertensive older women and that the decrease in systolic BP is associated with an increase in plasma NOx concentration.