Zhen Rong

Zhen Rong


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2019 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
CWChongwen Wang
Chongwen Wang
CWChaoguang Wang
Chaoguang Wang
XWXiaolong Wang
Xiaolong Wang
KWKeli Wang
Keli Wang
YZYanhui Zhu
Yanhui Zhu
SWShengqi Wang
Shengqi Wang

1 May 2019 in Analytica Chimica Acta
Verified
Journal Article
Closed access
ZRZhen Rong
Zhen Rong
QWQiong Wang
Qiong Wang
NSNanxi Sun
Nanxi Sun
XJXiaofei Jia
Xiaofei Jia
KWKeli Wang
Keli Wang
SWShengqi Wang
Shengqi Wang

5 September 2016 in The Analyst
Verified
Journal Article
Closed access
PDF file
CWChongwen Wang
Chongwen Wang
JWJunfeng Wang
Junfeng Wang
MLMin Li
Min Li
XQXinyan Qu
Xinyan Qu
KZKehan Zhang
Kehan Zhang
SWShengqi Wang
Shengqi Wang
A rapid, sensitive, and label-free SERS detection method for bacteria pathogens is reported for the first time. The method, which is based on the combination of polyethylenimine (PEI)-modified Au-coated magnetic microspheres (Fe3O4@Au@PEI) and concentrated Au@Ag nanoparticles (NPs), was named the capture–enrichment–enhancement (CEE) three-step method. A novel Fe3O4@Au microsphere with monodispersity and strong magnetic responsiveness was synthesized as a magnetic SERS substrate and amino functionalized by PEI self-assembly. The negatively charged bacteria were quickly captured and enriched by the positively charged Fe3O4@Au@PEI microspheres, and the bacteria SERS signal was synergistically enhanced by using Fe3O4@Au@PEI microspheres and Au@Ag NPs in conjunction. The CEE three-step method proved useful in tap water and milk samples, and the total assay time required was only 10 min. Results further demonstrated that the CEE three-step method could be a common approach for detecting a wide range of bacteria, as verified by its detection of the Gram-positive bacterium E. coli and Gram-positive bacterium S. aureus at a detection limit of as low as 103 cells per mL. Therefore, our CEE three-step method offered the significant advantages of short assay time, simple operating procedure, and higher sensitivity than previously reported methods of SERS-based bacteria detection.

1 December 2019 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
CWChongwen Wang
Chongwen Wang
RXRui Xiao
Rui Xiao
SWShu Wang
Shu Wang
XYXingsheng Yang
Xingsheng Yang
ZBZikun Bai
Zikun Bai
SWShengqi Wang
Shengqi Wang

19 August 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
Chongwen WangChongwen Wang
Chongwen Wang
XCXiaodan Cheng
Xiaodan Cheng
LLLiyan Liu
Liyan Liu
XZXiaochang Zhang
Xiaochang Zhang
XYXingsheng Yang
Xingsheng Yang
SWShengqi Wang
Shengqi Wang

16 April 2024 in Nature Communications
Verified
Journal Article
Open access
PDF file
YWYunxiang Wang
Yunxiang Wang
HCHong Chen
Hong Chen
KLKai Lin
Kai Lin
YHYongjun Han
Yongjun Han
ZGZhixia Gu
Zhixia Gu
SWShengqi Wang
Shengqi Wang
The emerging monkeypox virus (MPXV) has raised global health concern, thereby highlighting the need for rapid, sensitive, and easy-to-use diagnostics. Here, we develop a single-step CRISPR-based diagnostic platform, termed SCOPE (Streamlined CRISPR On Pod Evaluation platform), for field-deployable ultrasensitive detection of MPXV in resource-limited settings. The viral nucleic acids are rapidly released from the rash fluid swab, oral swab, saliva, and urine samples in 2 min via a streamlined viral lysis protocol, followed by a 10-min single-step recombinase polymerase amplification (RPA)-CRISPR/Cas13a reaction. A pod-shaped vest-pocket analysis device achieves the whole process for reaction execution, signal acquisition, and result interpretation. SCOPE can detect as low as 0.5 copies/µL (2.5 copies/reaction) of MPXV within 15 min from the sample input to the answer. We validate the developed assay on 102 clinical samples from male patients / volunteers, and the testing results are 100% concordant with the real-time PCR. SCOPE achieves a single-molecular level sensitivity in minutes with a simplified procedure performed on a miniaturized wireless device, which is expected to spur substantial progress to enable the practice application of CRISPR-based diagnostics techniques in a point-of-care setting.