Rosa Mendaza-DeCal

Ms. Rosa Mendaza-DeCal

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 July 2023 in Research in Veterinary Science
Verified
Journal Article
Open access
RMRosa Mendaza-DeCal
Rosa Mendaza-DeCal
SPSalvador Peso-Fernandez
Salvador Peso-Fernandez
JRJesus Rodriguez-Quiros
Jesus Rodriguez-Quiros
Orthoses and socket prostheses are rarely used orthopaedic devices in veterinary medicine. Recently, more pet owners have sought these treatments for pets with orthopaedic conditions. However, veterinarians often lack substantial scientific evidence on device outcomes and may expect high costs, the main limiting factor, if human orthopaedic market prices are assumed. This discrepancy creates an imbalance between pet owners' expectations, veterinarians' recommendations, and actual patient benefits. To address economic constraints and enhance knowledge about these devices, this study used 3D technology-namely 3D scanning and printing via fused deposition modelling-to design, modify, and manufacture orthoses and socket prostheses for ten patients, including nine dogs and one calf. An equation was devised and applied to all printed devices to streamline the resizing process for sockets and orthoses. The 3D-printed devices were fitted to the patients, and their adaptation was assessed using three novel scales based on prior scientific literature in the small animal orthopaedic field. The orthoses were well-tolerated, with successful and straightforward adaptation. Although socket prostheses were tolerated, the dogs' adaptation was suboptimal, while the calf demonstrated excellent and immediate adaptation.

26 August 2021 in Frontiers in Mechanical Engineering
Verified
Journal Article
Open access
RMRosa Mendaza-DeCal
Rosa Mendaza-DeCal
SPSalvador Peso-Fernandez
Salvador Peso-Fernandez
JRJesus Rodriguez-Quiros
Jesus Rodriguez-Quiros
Total limb amputation is quite common in small animals, although most of the indicated pathologies do not need such a restrictive procedure. Exo-endoprosthesis is a suggested alternative for the enhancement of the biomechanical situation of these patients. 3D printing of the internal part of exo-endoprostheses in polyether ether ketone (PEEK) is evaluated. Two different shapes of this internal part—one for radius’ and the other for cylindrical medullary cavities—were assessed. Proper PEEK temperature settings for 3D printing, the internal part of exo-endoprostheses, by fused filament fabrication (FFF) were obtained. Printing trials were carried out for different dimensions and printing orientation of these parts to achieve the best bone anchorage and thread strength outcomes. Pull-off strength tests for different surfaces of the internal part were performed with a best outcome for positive surfaces. All printed internal parts were inserted in canine tibiae and radii for an ex vivo assessment of bone anchorage and thread strength parameters. The best printing results were obtained at 410 and 130°C of the nozzle and bed temperatures, respectively. Also, a positive correlation was observed between the printing code, quality, and take-off time, while inverse correlation was shown between the take-off and the printing code, or quality, just like the print-bed temperature and the printing code. The positive surfaces had the best pull-off strength outcomes. Excellent bone anchorage and thread strength outcomes were obtained for one variant of each internal part shape. Designed devices had shown good threaded rod’s fitting inside the PEEK plug and perfect bone anchorage of the PEEK plug for tibiae and radii. In addition, iteration of manufacturing PEEK small devices by FFF technology has been shown due to small standard deviation of most variants.

31 March 2024 in Animals
Verified
Journal Article
Open access
PDF file
David Díaz-RegañónDavid Díaz-Regañón
David Díaz-Regañón
RMRosa Mendaza-DeCal
Rosa Mendaza-DeCal
Mercedes García-SanchoMercedes García-Sancho
Mercedes García-Sancho
FRFernando Rodríguez-Franco
Fernando Rodríguez-Franco
Ángel SainzÁngel Sainz
Ángel Sainz
CRConcepción Rojo
Concepción Rojo
A teaching strategy using 3D-printed models of the canine upper digestive tract (UDT) for anatomy demonstration and upper endoscopy instruction was evaluated. The canine UDT (esophagus–stomach–duodenum) was scanned and 3D-printed molds were manufactured using silicone casting. First-year students were introduced to these 3D models in practical sessions alongside real specimens. Simultaneously, fifth-year students were trained in endoscope handling and anatomical recognition using 3D specimens. Both groups completed an anonymous survey. Results showed that overall, first-year (n = 93) and fifth-year (n = 45) students agreed or strongly agreed that the 3D-printed model was effective for learning purposes. In summary, first-year students highlighted an improved understanding of size, volume, topography, and easier manipulation of the 3D model compared to fresh specimens. Fifth-year students were more enthusiastic, finding the 3D model valuable for spatial vision and clinical training. While both groups were against completely replacing the natural UDT with the 3D model, first-year students were more hesitant. These findings suggest that the 3D model of the canine UDT is an effective tool for hands-on training in clinical endoscopy and a valuable, albeit complementary, resource for teaching anatomy and topography.

3 November 2022 in Animals
Verified
Journal Article
Open access
PDF file
RMRosa Mendaza-DeCal
Rosa Mendaza-DeCal
YIYolanda Ballesteros Iglesias
Yolanda Ballesteros Iglesias
SPSalvador Peso-Fernandez
Salvador Peso-Fernandez
Juan del Real-RomeroJuan del Real-Romero
Juan del Real-Romero
JRJesus Rodriguez-Quiros
Jesus Rodriguez-Quiros
Exo-endoprosthesis is a limb salvage procedure poorly described for animals, as only expensive metal devices have been used so far. Currently, additive manufacturing (AM) can make this type of implant affordable by exploring a wide new range of materials. However, safety factors should be considered and could be related to kinetic and kinematic studies of canine natural gaits. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was assessed for long canine bones with an elliptical medullary canal. Polyether ether ketone (PEEK) was the material used as an alternative to metal for veterinary traumatology. Poisson’s ratio of 3D-printed PEEK material and ex vivo mechanical tests of the customized endoprosthesis were performed for the evaluation. The customized endoprostheses had promising outcomes for the radii of 20 kg dogs. Quasistatic mechanical tests of bone-inserted endoprostheses—pure compression tests—reached a maximum force of 1045.0 ± 78.0 N. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. Furthermore, torque tests with different adhesives were performed to obtain reference data for future assessments comparing with natural dog movements.

30 June 2022 in Frontiers in Veterinary Science
Verified
Journal Article
Open access
RMRosa Mendaza-DeCal
Rosa Mendaza-DeCal
YBYolanda Ballesteros
Yolanda Ballesteros
SPSalvador Peso-Fernandez
Salvador Peso-Fernandez
EPEva Paz
Eva Paz
JRJuan Carlos del Real-Romero
Juan Carlos del Real-Romero
JRJesus Rodriguez-Quiros
Jesus Rodriguez-Quiros
Exo-endoprosthesis is a limb salvage procedure for animals, although only expensive metal devices have been described. Now-a-days, new materials for this type of implant could be considered due to novel and affordable manufacturing techniques. However, a factor of safety (FoS) should be considered. There are kinetic and kinematic studies of canine natural gaits, which can be used to establish an FoS for mechanical tests for new non-metallic devices. Polyetheretherketone (PEEK) is used in different specialties in human medicine. Its mechanical properties (and its close mechanical stiffness to that of bone) make this polymer an alternative to metals in veterinary traumatology. PEEK could also be used in 3D printing. The suitability of a novel inner part of an exo-endoprosthesis manufactured by fuse deposition modeling (FDM) was presented in this study for long canine bones. Mechanical characterization of 3D-printed PEEK material and ex vivo mechanical tests of a customized endoprosthesis were performed to address it. Young's modulus of 3D-printed PEEK suffered a reduction of 30% in relation to bulk PEEK. Customized 3D-printed PEEK endoprostheses had promising outcomes for the tibiae of 20 kg dogs. Pure compression tests of the non-inserted endoprostheses showed a maximum force of 936 ± 199 N. In the bending tests of non-inserted endoprostheses, the PEEK part remained intact. Quasistatic mechanical tests of bone-inserted endoprostheses (compression-bending and pure compression tests) reached a maximum force of 785 ± 101 N and 1,642 ± 447 N, respectively. In fatigue tests, the samples reached 500,000 cycles without failure or detriment to their quasistatic results. These outcomes surpass the natural weight-bearing of dogs, even during a galloping pace. In conclusion, the 3D-printed PEEK part of the endoprosthesis for an exo-endoprosthesis can withstand loading, even during a galloping pace.

13 June 2026 in Veterinary Research Communications
Verified
Journal Article
Closed access
RMRosa Mendaza-DeCal
Rosa Mendaza-DeCal
SPSalvador Peso-Fernandez
Salvador Peso-Fernandez
JRJesus Rodriguez-Quiros
Jesus Rodriguez-Quiros