Ihsan Caglar Cinar

Ihsan Caglar Cinar


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Alper SaglanmakAlper Saglanmak
Alper Saglanmak
ICIhsan Caglar Cinar
Ihsan Caglar Cinar
Mohammed ZbounMohammed Zboun
Mohammed Zboun
Volkan ArısanVolkan Arısan
Volkan Arısan
Eitan MijiritskyEitan Mijiritsky
Eitan Mijiritsky
Background/Objectives: The aim of this retrospective study was to radiographically evaluate the endo-sinus bone gain (ESBG) following osseodensification procedures using CBCT and compare the results to more conventional sinus lifting techniques. Methods: A total of 72 patients underwent crestal sinus floor elevation procedures and were provided with 102 implants with a sand-blasted and acid-etched surface with microthreads (Medentika® Microcone Implants, Hugelsheim, Germany). Patients were divided into two groups; the osseodensification group (OD; n = 36) and the osseodensified augmentation group (ODA; n = 36). Results: The mean residual bone height (RBH) was 5.71 (1.77) and 4.30 (0.94) mm in the OD and ODA groups, respectively. An ESBG of 3.45 (1.18) and 5.74 (1.31) mm was observed in the OD and ODA groups, respectively, and as compared to the baseline RBH, the ESBG was statistically significant in both groups after 6 months (p < 0.001). Conclusions: Within the limits of this retrospective study, crestal sinus lifting with the osseodensification technique seems to be a fast, effective, and safe method. Longer follow-up studies with full intrasinus bone topography and structure analyses are needed to prove the success rate of endo-sinus bone gain.

18 October 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
ICIhsan Caglar Cinar
Ihsan Caglar Cinar
BGBahattin Alper Gultekin
Bahattin Alper Gultekin
ASAlper Saglanmak
Alper Saglanmak
AAAyse Sumeyye Akay
Ayse Sumeyye Akay
Mohammed ZbounMohammed Zboun
Mohammed Zboun
Eitan MijiritskyEitan Mijiritsky
Eitan Mijiritsky
(1) Background: Bone Lamina Technique and Guided Bone Regeneration (GBR) are commonly used for horizontally-deficient maxillary ridge reconstruction, although more detailed evaluation to assess the differences between such techniques is necessitated. (2) Methods: In this retrospective study, patients having a horizontal bone width of ≤4 mm in the maxilla, who were treated with Cortical Strut (CS), were collected to represent the “test group”, and those treated with GBR with no CS involvement represented the “control group”. A 1:1 mixture of autogenous bone (AB) and anorganic bovine bone (ABB) with resorbable collagen membrane was applied to both groups. Volumetric changes between groups were measured with cone-beam computed tomography (CBCT). The primary outcome represented volumetric graft resorption rate whilst the secondary outcomes represented any probable complications and implant insertion torque. (3) Results: A total of 36 patients were included in this study (36 grafted sites; 18 for CS group and 18 for GBR group). Mean bone graft volume reduction in the CS and GBR groups was 8.26 ± 1.60% and 14.36 ± 3.55%, respectively. The GBR group showed significantly more bone resorption than the CS group (p < 0.001). Complications and insertion torque were similar between the groups (p > 0.05). (4) Conclusions: Both CS and GBR techniques for hard-tissue augmentation provided sufficient bone graft mass volume for implant insertion, whereas CS demonstrated lower resorption rate at maxillary augmented sites, compared to GBR.

1 September 2023
Verified
Journal Article
Closed access
ICIhsan Caglar Cinar
Ihsan Caglar Cinar
Mohammed ZbounMohammed Zboun
Mohammed Zboun
BGBahattin Alper Gultekin
Bahattin Alper Gultekin
ASAlper Saglanmak
Alper Saglanmak
AAAyse Sumeyye Akay
Ayse Sumeyye Akay

Verified
Journal Article
Open access
PDF file
DKDilan Karahan
Dilan Karahan
ICIhsan Caglar Cinar
Ihsan Caglar Cinar
Dental implant placement in the posterior mandible can be challenging due to the presence of the inferior alveolar nerve (IAN). Biomechanical factors related to implant design and loading may also influence nerve compression. This study aimed to investigate the influence of implant geometry, diameter, length, and implant–canal distance on IAN pressure. Dental implants with two geometries (tapered and cylindrical), two lengths (8 and 12 mm), and two diameters (3.3 and 4.1 mm) were virtually positioned at three implant–canal distances (0.5, 1.0, and 1.5 mm). A total of 24 finite element models were generated. Functional occlusal loading was simulated using a 300 N vertical force and a 100 N oblique force applied at a 45° angle. The resulting IAN pressure values were determined. The implant diameter affected IAN pressure, with 3.3 mm implants yielding higher values than 4.1 mm implants. Longer implants exhibited lower pressure values than shorter implants. Cylindrical implants generated higher pressure than tapered implants. Increasing the implant–canal distance from 0.5 to 1.5 mm reduced nerve pressure. Vertical loading yielded higher pressure values than oblique loading. The implant–canal distance was the primary factor influencing IAN pressure. Implant diameter and geometry had secondary effects, whereas implant length had a limited influence. These findings highlight the importance of implant planning and design selection to reduce load transfer to the IAN.