Erica D Dawson

Dr. Erica D Dawson


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 June 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GWGarrett Wilson
Garrett Wilson
ZYZhiping Ye
Zhiping Ye
HXHang Xie
Hang Xie
SVSteven Vahl
Steven Vahl
EDErica D Dawson
Erica D Dawson
KRKathy Rowlen
Kathy Rowlen
The hemagglutination inhibition assay (HAI) is widely used to evaluate vaccine-induced antibody responses as well as to antigenically characterize influenza viruses. The results of an HAI assay are based on an endpoint titration where the titers are generally manually interpreted and recorded by a well-trained expert. For serological applications, the lack of standardization in endpoint interpretation and interference from non-specific inhibitors in clinical samples can translate into a high degree of variability in the results. For example, tilting HAI plates at 45–60 degrees to look for a “tear drop pattern” with avian red blood cells is a common practice by many, but not all, research laboratories. In this work, we tested the hypothesis that an automated image analysis algorithm can be used to achieve an accurate and non-subjective interpretation of HAI assays—specifically without the need to tilt plates. In a side-by-side comparison study performed during FDA’s biannual serological screening process for influenza viruses, titer calls for more than 2200 serum samples were made by the Cypher One automated hemagglutination analyzer without tilting and by an expert human with tilting. The comparison yielded 95.6% agreement between the expert reader and automated interpretation method (within ± 1 dilution) for the complete dataset. Performance was also evaluated relative to the type of red blood cell (turkey and guinea pig) and influenza strain (12 different viruses). For the subset that utilized guinea pig red blood cells (~44% of the samples), for which no plate tilting was required, the agreement with an expert reader was 97.2%. For the subset that utilized turkey red blood cells (~56% of the samples), for which plate tilting was necessary by the expert reader, the agreement was 94.3%. Overall these results support the postulate that algorithm-based interpretation of a digital record with no plate tilting could replace manual reading for greater consistency in HAI assays.

6 January 2012 in Journal of Clinical and Experimental Neuropsychology
Verified
Journal Article
Closed access
EDErica L. Dawson
Erica L. Dawson
PSPaula K. Shear
Paula K. Shear
SSStephen M. Strakowski
Stephen M. Strakowski
Impulsive behavior is thought to lead to both positive and negative psychosocial outcomes. However, little is known about the potential consequences of subclinical expressions of behavior dysregulation on everyday functioning. To examine this relationship, global social functioning was measured in 89 healthy, young adults who also completed the Degraded Stimulus Continuous Performance Test, Color–Word Interference Test, Barratt Impulsiveness Scale, 11th Edition, and Behavior Rating Inventory of Executive Functioning–Adult. Better self-reported executive functioning and mood were significant independent predictors of higher social functioning, even in a sample of healthy adults. The results of this study may serve as a foundation for comparison with clinical populations who demonstrate greater behavior dysregulation and mood instability.

24 April 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
EDErica L. Dawson
Erica L. Dawson
MMMaria C. B. Mendoza
Maria C. B. Mendoza
ZGZaneta Gaul
Zaneta Gaul
WIWilliam L. Jeffries Iv
William L. Jeffries Iv
MSMadeline Y. Sutton
Madeline Y. Sutton
PWPatrick A. Wilson
Patrick A. Wilson
Black men who have sex with men, who account for less than 1% of the U.S. population, account for approximately 25% of new HIV infections annually. Condomless anal sex contributes to HIV infection among black men who have sex with men. The capacity to recover quickly from difficulties (resilience) may be protective against condomless anal sex, but has been understudied among black men who have sex with men. Psychosocial factors related to resilience, i.e., condom use self-efficacy and internalized homophobia, may also affect condomless anal sex. We assessed the association between resilience, condom use self-efficacy, internalized homophobia and condomless anal sex among black men who have sex with men. Data are from a 2010–2011 study examining condomless anal sex (past 60 days) among black men who have sex with men in New York City. Validated scales assessed resilience (theoretical range = 0–100), condom use self-efficacy (theoretical range = 27–135), and internalized homophobia (theoretical range = 9–36). We described continuous variables using median and interquartile range (IQR). Univariable and multivariable Poisson regression models assuming a robust variance estimator were used to compute unadjusted and adjusted prevalence ratios, respectively, and their corresponding 95% confidence intervals (CI). Adjusted prevalence ratios (aPR) examined the association of resilience, condom use self-efficacy, and internalized homophobia with condomless anal sex, while controlling for potential confounders (e.g., having >1 sex partner). The median resilience score within our sample (N = 228) was 75 (IQR = 66–83). Many black men who have sex with men reported condomless anal sex (55.7%) and >1 sex partner (58.8%). Decreased condomless anal sex was associated with increased levels of condom use self-efficacy (aPR: 0.94 per 10-point increase in condom use self-efficacy score; CI: 0.90–0.97; p-value: 0.001). Condomless anal sex was not associated with resilience or internalized homophobia. Within this sample of black men who have sex with men, condomless anal sex was prevalent. Greater resilience was not protective against condomless anal sex. Interventions that support condom use are warranted for black men who have sex with men.

21 January 2009 in Molecular Biotechnology
Verified
Journal Article
Closed access
PDF file
EDErica D Dawson
Erica D Dawson
ATAmber W. Taylor
Amber W. Taylor
JSJames A. Smagala
James A. Smagala
KRKathy L. Rowlen
Kathy L. Rowlen

1 May 2021 in Journal of Virological Methods
Verified
Journal Article
Open access
EDErica D Dawson
Erica D Dawson
LKLaura R. Kuck
Laura R. Kuck
RBRebecca H. Blair
Rebecca H. Blair
ATAmber W. Taylor
Amber W. Taylor
ETEvan Toth
Evan Toth
KRKathy L. Rowlen
Kathy L. Rowlen
Rapid, sensitive, and precise multiplexed assays for serological analysis during candidate COVID-19 vaccine development would streamline clinical trials. The VaxArray Coronavirus (CoV) SeroAssay quantifies IgG antibody binding to 9 pandemic, potentially pandemic, and endemic human CoV spike antigens in 2 h with automated results analysis. IgG antibodies in serum bind to the CoV spike protein capture antigens printed in a microarray format and are labeled with a fluorescent anti-species IgG secondary label. The assay demonstrated excellent lower limits of quantification ranging from 0.3 to 2.0 ng/mL and linear dynamic ranges of 76 to 911-fold. Average precision of 11 % CV and accuracy (% recovery) of 92.5 % over all capture antigens were achieved over 216 replicates representing 3 days and 3 microarray lots. Clinical performance on 263 human serum samples (132 SARS-CoV-2 negatives and 131 positives based on donor-matched RT-PCR and/or date of collection) produced 98.5 % PPA and 100 % NPA.

12 October 2022 in Vaccines
Verified
Journal Article
Open access
PDF file
RGRachel Y Gao
Rachel Y Gao
CRChristine M. Riley
Christine M. Riley
ETEvan Toth
Evan Toth
RBRebecca H. Blair
Rebecca H. Blair
MGMegan N Gerold
Megan N Gerold
EDErica D Dawson
Erica D Dawson
The COVID-19 pandemic highlighted mRNA as a promising platform for vaccines and therapeutics. Many of the analytical tools used to characterize the critical quality attributes of mRNA are inherently singleplex and are not necessarily optimal from a labor and cost perspective. Here, we demonstrate the feasibility of a multiplexed platform (VaxArray) for efficient identity verification and concentration determination for both monovalent and multivalent mRNA formulations. A model system comprising mRNA constructs for influenza hemagglutinin and neuraminidase was used to characterize the analytical performance metrics for a VaxArray mRNA assay. The assay presented herein had a time to result of less than 2 h, required no PCR-based amplification nor extraction of mRNA from lipid nanoparticles, and exhibited high construct specificity that enabled application to the bivalent mixture. The sensitivity for influenza hemagglutinin and neuraminidase mRNA was sub-µg/mL, which is vaccine-relevant, and the average accuracy (%recovery of a check standard) and precision were 104 ± 2% and 9 ± 2%, respectively.