Pravarthana Dhanapal

Dr. Pravarthana Dhanapal

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 November 2018 in Advanced Electronic Materials
Verified
Journal Article
Closed access
PDF file
XYXiaohui Yi
Xiaohui Yi
ZYZhe Yu
Zhe Yu
XNXuhong Niu
Xuhong Niu
JSJie Shang
Jie Shang
GMGuoyong Mao
Guoyong Mao
Run-Wei LiRun-Wei Li
Run-Wei Li

28 June 2018 in Advanced Electronic Materials
Verified
Journal Article
Closed access
PDF file
ZYZhe Yu
Zhe Yu
JSJie Shang
Jie Shang
XNXuhong Niu
Xuhong Niu
YLYiwei Liu
Yiwei Liu
GLGang Liu
Gang Liu
Run-Wei LiRun-Wei Li
Run-Wei Li

6 September 2011 in Langmuir
Verified
Journal Article
Closed access
SVSeema Verma
Seema Verma
DPD. Pravarthana
D. Pravarthana

27 May 2013 in Applied Physics Letters
Verified
Journal Article
Closed access
SBShekhar D. Bhame
Shekhar D. Bhame
DPDhanapal Pravarthana
Dhanapal Pravarthana
WPWilfrid Prellier
Wilfrid Prellier
JNJacques G. Noudem
Jacques G. Noudem
Bulk p and n-type bismuth tellurides were prepared using spark plasma texturization method. The texture development along the uniaxial load in the 001 direction is confirmed from both x-ray diffraction analysis and electron backscattering diffraction measurements. Interestingly, those textured samples outperform the samples prepared by conventional spark plasma sintering (SPS) leading to a reduced thermal conductivity in the ab-plane. The textured samples of n-type BiTe2.7Se0.3 and p-type Bi0.5Sb1.5Te3 showed a 42% and 33% enhancement in figure of merit at room temperature, respectively, as compared to their SPS counterparts, opening the route for applications.

18 March 2020 in Global Challenges
Verified
Journal Article
Open access
PDF file
YZYa‐Nan Zheng
Ya‐Nan Zheng
ZYZhe Yu
Zhe Yu
GMGuoyong Mao
Guoyong Mao
YLYunyao Li
Yunyao Li
DPDhanapal Pravarthana
Dhanapal Pravarthana
Run-Wei LiRun-Wei Li
Run-Wei Li
Wearable sensors are gradually enabling decentralized healthcare systems. However, these sensors need to be closely attached to skin, which is unsuitable for long‐term dynamic health monitoring of the patients, such as infants or persons with burn injuries. Here, a wearable capacitive sensor based on the capacitively coupled effect for healthcare monitoring in noncontact mode is reported. It consists of a ring‐shaped top electrode, a disk‐shaped bottom electrode, and a porous dielectric layer with low permittivity. This unique design enhanced the capacitively coupled effect of the sensor, which enables a high noncontact detectivity of capacitance change. When an object approaches the sensor, its capacitance change (ΔC/Ci = −38.7%) is 3–5 times higher than that of previously reported sensors. Meanwhile, the sensor is insensitive to the stretching strain and pressure (ΔC/Ci < 5%) due to the unique ring‐shaped electrode and the incompressible closed cells of the porous dielectric material, respectively. Finally, various human physiological signals (pulse and respiratory) are recorded in noncontact mode, where a person wears loose and soft clothes implanted with the sensor. Thus, it is promising to build smart healthcare clothes based on it to develop wearable decentralized healthcare systems.

16 July 2014 in The Journal of Physical Chemistry C
Verified
Journal Article
Closed access
SVSeema Verma
Seema Verma
AKAmit Kumar
Amit Kumar
DPD. Pravarthana
D. Pravarthana
ADAparna Deshpande
Aparna Deshpande
SOSatishchandra B. Ogale
Satishchandra B. Ogale
SYS. M. Yusuf
S. M. Yusuf