Mitul Ranjan Chakraborty

Mr. Mitul Ranjan Chakraborty


Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2022 in Batteries
Verified
Journal Article
Open access
PDF file
MCMitul Ranjan Chakraborty
Mitul Ranjan Chakraborty
SDSubhojit Dawn
Subhojit Dawn
PSPradip Kumar Saha
Pradip Kumar Saha
jayanta bhusan basujayanta bhusan basu
jayanta bhusan basu
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
Electrical energy is critical to the advancement of both social and economic growth. Because of its importance, the electricity industry has historically been controlled and operated by governmental entities. The power market is being deregulated, and it has been modified throughout time. Both regulated and deregulated electricity markets have benefits and pitfalls in terms of energy costs, efficiency, and environmental repercussions. In regulated markets, policy-based strategies are often used to deal with the costs of fossil fuel resources and increase the feasibility of renewable energy sources. Renewables may be incorporated into deregulated markets by a mix of regulatory and market-based approaches, as described in this paper, to increase the systems economic stability. As the demand for energy has increased substantially in recent decades, particularly in developing nations, the quantity of greenhouse gas emissions has increased fast, as have fuel prices, which are the primary motivators for programmers to use renewable energy sources more effectively. Despite its obvious benefits, renewable energy has considerable drawbacks, such as irregularity in generation, because most renewable energy supplies are climate-dependent, demanding complex design, planning, and control optimization approaches. Several optimization solutions have been used in the renewable-integrated deregulated power system. Energy storage technology has risen in relevance as the usage of renewable energy has expanded, since these devices may absorb electricity generated by renewables during off-peak demand hours and feed it back into the grid during peak demand hours. Using renewable energy and storing it for future use instead of expanding fossil fuel power can assist in reducing greenhouse gas emissions. There is a desire to maximize the societal benefit of a deregulated system by better using existing power system capacity through the implementation of an energy storage system (ESS). As a result, good ESS device placement offers innovative control capabilities in steady-state power flow regulation as well as dynamic stability management. This paper examines numerous elements of renewable integrated deregulated power systems and gives a comprehensive overview of the most current research breakthroughs in this field. The main objectives of the reviews are the maximization of system profit, maximization of social welfare and minimization of system generation cost and loss by optimal placement of energy storage devices and renewable energy systems. This study will be very helpful for the power production companies who want to build new renewable-based power plant by sighted the present status of renewable energy sources along with the details of several EES systems. The incorporation of storage devices in the renewable-incorporated deregulated system will provide maximum social benefit by supplying additional power to the thermal power plant with minimum cost.

23 November 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
jayanta bhusan basujayanta bhusan basu
jayanta bhusan basu
SDSubhojit Dawn
Subhojit Dawn
PSPradip Kumar Saha
Pradip Kumar Saha
MCMitul Ranjan Chakraborty
Mitul Ranjan Chakraborty
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
Studying the property of the combination of renewable energy sources in the existing power systems is of great importance, and especially in the case of deregulated systems. The uncertainty of renewable sources is the largest barrier to integrating renewable-energy-producing units into the existing electrical infrastructure. Due to its uncertainty, integrating wind power into an existing power system requires extra consideration. In this work, the impacts of wind farm (WF) integration and a pumped hydroelectric storage system (PHES) on the electric losses, voltage profiles, generation costs, and system economy in a deregulated power market were studied. A comparative study was performed to determine the impact of wind farm integration on regulated and deregulated environments. Four locations in India were chosen at random for this work, and we used the real-time statistics for the actual wind speeds (AWSs) and forecasted wind speeds (FWSs) for each chosen location. To determine the system economy, surplus charge rates and deficit charge rates were developed to evaluate the imbalance cost resulting from the mismatch between the predicted and actual wind speeds. Considering the effect of the imbalance cost, the system profit/day varies by an average of 1.6% for the locations studied. Because of the reorganization of the power system, consumers constantly look for reliable and affordable power that is also efficient. As a result, the system security limit may be breached, or the system may run in a dangerous state. Lastly, in this paper, an economic risk analysis is presented with the help of heuristic algorithms (i.e., artificial bee colony algorithm (ABC) and moth–flame optimization algorithm (MFO)), along with sequential quadratic programming (SQP), and the way in which the PHES is used to compensate for the deviation in the WF integration in the real-time electricity market is also presented. The value at risk (VaR) and conditional value at risk (CVaR) were used as the economic risk analysis tools. According to the work, with the increase in the wind generation, the system risk improves. The results show that, as the wind generation increases by three times, there is an improvement in the risk coefficient values by 1%. A modified IEEE 14-bus test system was used for the validation of the entire work.

9 September 2022 in Electronics
Verified
Journal Article
Open access
PDF file
jayanta bhusan basujayanta bhusan basu
jayanta bhusan basu
SDSubhojit Dawn
Subhojit Dawn
PSPradip Kumar Saha
Pradip Kumar Saha
MCMitul Ranjan Chakraborty
Mitul Ranjan Chakraborty
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
Electrical energy plays a key role in the development of the social as well as the economic front. The power sector has historically been owned and operated by state agencies due to its tremendous importance. It has been restructured over time, and the power market is being deregulated. In terms of consumer prices, efficiency, and environmental implications, both regulated and deregulated electricity markets offer advantages and disadvantages. Policy-based techniques are typically used in regulated markets to address the costs of fossil-fuel resources and boost the viability of renewable energy sources. Renewables can be integrated into deregulated markets through a combination of regulatory and market-based measures to extend the system’s economic stability which has been deployed in this paper. As the need for energy has expanded dramatically over the last few decades, particularly in developing countries, the amount of greenhouse gas emissions has climbed rapidly, as have fuel prices, which are the key driving forces behind initiatives to use renewable energy sources more effectively. Despite the apparent benefits of renewable energy, it has significant downsides, such as generation of optimization methods applied to renewable consistency, because most renewable energy supplies are climate-dependent, necessitating complicated design, planning, and control optimization methods. There have been numerous optimization strategies applied to the renewable integrated deregulated electricity system. With the increased use of renewable energy, energy storage technology has grown in importance, as these devices can capture electricity generated by renewables during off-peak demand hours and put it back into the grid during peak demand periods. Using stored renewable energy instead of adding generation based on fossil fuel can help to minimize greenhouse gas emissions. There is an interest in better utilizing available power system capacity by implementing FACTS to maximize the social benefit in a deregulated system. As a result, effective FACTS device placement provides novel control capabilities in both steady-state power flow regulation and dynamic stability control. This study reviews several aspects of renewable integrated deregulated power systems and provides a clear picture of the most recent research developments on this subject. The main objectives of the reviews are the maximization of system profit, maximization of social welfare, and minimization of system generation cost and loss by optimal placement of energy storage devices and FACTS controllers.

6 February 2023 in Energies
Verified
Journal Article
Open access
PDF file
MCMitul Ranjan Chakraborty
Mitul Ranjan Chakraborty
SDSubhojit Dawn
Subhojit Dawn
PSPradip Kumar Saha
Pradip Kumar Saha
jayanta bhusan basujayanta bhusan basu
jayanta bhusan basu
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
It is important to understand the features of an integrated renewable energy power system, especially for deregulated systems. The greatest obstacle to assimilating renewable energy generators with the existing electrical system is their unpredictability. Because wind energy is inconsistent, incorporating it into an established power system necessitates more planning. The effects of wind farm (WF) incorporation with fuel cells and a unified power flow controller (UPFC) on electric losses, voltage profile, generating price, and the economics of the system in a deregulated power market are examined in this paper. An impact analysis of integrating wind farms into controlled and uncontrolled situations is conducted. At two randomly selected locations in India, the real-time statistics of the actual wind speed (AWS) and forecasted wind speed (FWS) were merged for this study. The surplus charge rate and deficit charge rate are intended to evaluate the imbalance cost which is arising from the difference between anticipated and true wind speeds to determine the economics of the system. Customers are always trying to find electricity that is reliable, inexpensive, and efficient due to the reconfiguration of the power system. As a consequence, the security limitations of the system may be surpassed or might function beyond the safety limit, which is undesirable. In the last section, heuristic algorithms, such as sequential quadratic programming (SQP), artificial bee colony algorithms (ABC), and moth-flame optimization algorithms (MFO), are employed to analyze economic risk. In the real-time energy market, it also covers how the fuel cells and UPFC are utilized to rectify the WF integration’s deviation. Economic risk evaluation approaches include value-at-risk (VaR) and conditional value-at-risk (CVaR). A modified IEEE 30-bus test system is used throughout the whole project.

13 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
MCMitul Ranjan Chakraborty
Mitul Ranjan Chakraborty
SDSubhojit Dawn
Subhojit Dawn
PSPradip Kumar Saha
Pradip Kumar Saha
jayanta bhusan basujayanta bhusan basu
jayanta bhusan basu
Taha Selim UstunTaha Selim Ustun
Taha Selim Ustun
Studying a renewable energy integrated power system’s features is essential, especially for deregulated systems. The unpredictability of renewable sources is the main barrier to integrating renewable energy-producing units with the current electrical grid. Due to its unpredictable nature, integrating wind power into an existing power system requires significant consideration. In a deregulated electricity market, this paper examines the implications of wind farm (WF) integration with CAES on electric losses, voltage profile, generation costs, and system economics. Comparative research was done to determine the impact of wind farm integration on regulated and deregulated environments. Four randomly chosen locations in India were chosen for this investigation, together with real-time information on each location’s real wind speed (RWS) and predicted wind speed (PWS). Surplus charge rates and deficit charge rates were created to assess the imbalance cost arising from the discrepancy between predicted and real wind speeds to calculate the system economics. When the effect of imbalance cost is considered, the daily system profit shows a variation of about 1.9% for the locations under study. Customers are always seeking electricity that is dependable, affordable, and efficient due to the reorganization of the power system. As a result, the system security limit could be exceeded or the system might function dangerously. The final section of this paper presents an economic risk analysis using heuristic algorithms such as sequential quadratic programming (SQP), artificial bee colony algorithms (ABC), and moth flame optimization algorithms (MFO). It also discusses how the CAES is used to correct the deviation of WF integration in the real-time electricity market. Economic risk analysis tools include value-at-risk (VaR) and conditional value-at-risk (CVaR). The entire piece of work was validated using a modified IEEE 30-bus test system. This works shows that with a three-fold increase in wind generation, the risk coefficient values improves by 1%.