This paper deals with the topic of power quality in a local distribution grid. It is aimed to analyze the individual influences, which aggravate the power quality of the distribution grid. Based on the analysis, the most adverse effects were determined, and they were the voltage drops and supply voltage interruptions, supply voltage unbalance, load power factor, and also higher harmonics. These influences cause the technical losses in a distribution grid, which subsequently have a financial impact not only on the distribution, but also on the transmission of electricity. Only the load voltage unbalance, the load power factor, and the higher harmonics, which mainly cause the technical losses, were analyzed in this paper. The measurement of the influences of the adverse effects was performed on the model of a 22-kV distribution grid. The measurement was performed on the basis of three types of power line conductors and their different lengths, three types of active power consumption, and the different values of these adverse effects. According to this measurement, a simulation in program Matlab-Simulink was created. This simulation represented part of a 22-kV distribution grid, which was influenced by the abovementioned adverse effects. The results of the measurements were compared with the results of the simulation. Based on the evaluation of the technical losses from the measurement and the simulation, the financial losses during a certain period were calculated for the distribution system operators.
Nowadays, the issue of stray currents is very actual, especially due to origin of electrochemical corrosion of storage devices. The biggest sources of stray currents are direct current traction systems such as railways and city lines using rails as a return conductor. In many cases, the return current does not flow back to traction converter substation by rails but uses other paths such as metallic devices stored under the ground (pipelines, metal-coat cables). This results in stray currents formation, which is the main cause of electrochemical corrosion. Electrochemical corrosion may cause serious damage of storage devices situated especially in proximity of direct current electrical traction systems. This paper deals with the issue of stray currents, describes the formation, spreading and the method of stray current measurement. The final part of this paper analyzes the results from real measurement of stray currents originating mostly from city tram lines. Measured data indicates a high activity of stray currents which can lead to damaging of metallic devices stored under the ground.
The paper deals with designing and implementation of Smart Grid model with designing of power quality measurement software in these networks. There was created a simulation model which has the same parameters setting as the real network. Various renewable energy sources represented by small hydropower plant, photovoltaic power plant and wind power plant are integrated in the designed scheme of Smart Grid. A part of the real network model in laboratory environment is controlling and evaluating SCADA system which was designed in LabVIEW programme. This system provides real-time control of power switching relays, obtains information about their status and performs three-phase measurement. The basic system displays information about voltage, current, and total harmonic distortion. SCADA system can perform detailed power quality measurement in individual points. The system supplies three types of customers, namely industrial zone, a city and two villages. The entire system is connected into a mash-grid structure. Several analyses and measurements were carried out for the given structure in order to obtain results for optimal operation of the network focusing on the power quality in Smart Grid.
This article deals with the assessment of the reliability of sensitive equipment due to voltage sags. The most frequent problems of power quality are voltage sags. Equipment that cannot withstand short-term voltage sag is defined as sensitive device. Sensitivity of such equipment can be described by the voltage–tolerance curves. A device (generator) to generate voltage sags (also interruptions) with duration at least 1 ms has been designed and developed for this purpose. Equipment sensitive to voltage sags was tested using this generator. Overall, five types of sensitive equipment were tested: personal computers, fluorescent lamps, drives with speed control, programmable logic controllers, and contactors. The measured sensitivity curves of these devices have been used to determine the number of trips (failures) due to voltage sags. Two probabilistic methods (general probability method and cumulative probability method) to determine probability of equipment failure occurrence are used. These methods were applied to real node in the distribution system with its actual performance of voltage sags/swells. The calculations also contain different levels of sensitivity of the sensitive equipment.
1 January 2019 in Transportation Research Procedia