The identification of patients prone to atrial fibrillation (AF) relapse after catheter ablation is essential for better patient selection and risk stratification. The current prospective cohort study aims to validate a novel P-wave index based on beat-to-beat (B2B) P-wave morphological and wavelet analysis designed to detect patients with low burden AF as a predictor of AF recurrence within a year after successful catheter ablation. From a total of 138 consecutive patients scheduled for AF ablation, 12-lead ECG and 10 min vectorcardiogram (VCG) recordings were obtained. Univariate analysis revealed that patients with higher B2B P-wave index had a two-fold risk for AF recurrence (HR: 2.35, 95% CI: 1.24–4.44, p: 0.010), along with prolonged P-wave, interatrial block, early AF recurrence, female gender, heart failure history, previous stroke, and CHA2DS2-VASc score. Multivariate analysis of assessable predictors before ablation revealed that B2B P-wave index, along with heart failure history and a history of previous stroke or transient ischemic attack, are independent predicting factors of atrial fibrillation recurrence. Further studies are needed to assess the predictive value of the B2B index with greater accuracy and evaluate a possible relationship with atrial substrate analysis.
Left atrial (LA) fibrosis has been shown to be associated with atrial fibrillation (AF) recurrence. Beat-to-beat (B2B) index is a non-invasive classifier, based on B2B P-wave morphological and wavelet analysis, shown to be associated with AF incidence and recurrence. In this study, we tested the hypothesis that the B2B index is associated with the extent of LA low-voltage areas (LVAs) on electroanatomical mapping. Patients with paroxysmal AF scheduled for pulmonary vein isolation, without evident structural remodeling, were included. Pre-ablation electroanatomical voltage maps were used to calculate the surface of LVAs (<0.5 mV). B2B index was compared between patients with small versus large LVAs. 35 patients were included (87% male, median age 62). The median surface area of LVAs was 7.7 (4.4-15.8) cm2 corresponding to 5.6 (3.3-12.1) % of LA endocardial surface. B2B index was 0.57 (0.52-0.59) in patients with small LVAs (below the median) compared to 0.65 (0.56-0.77) in those with large LVAs (above the median) (p=0.009). In the receiver operator characteristic curve analysis for predicting large LVAs, the c-statistic was 0.75 (p=0.006) for B2B index and 0.81 for the multivariable model including B2B index (multivariable p=0.04) and P-wave duration. In patients with paroxysmal AF without overt atrial myopathy, B2B P-wave analysis appears to be a useful non-invasive correlate of low-voltage areas-and thus fibrosis-in the LA. This finding establishes a pathophysiological basis for B2B index and its potential usefulness in the selection process of patients who are likely to benefit most from further invasive treatment.