Jason Orion Jaeger

Dr. Jason Orion Jaeger

Southern California University of Health Sciences, Whittier, California, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2024 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
MHMohammad Mehdi Hosseini
Mohammad Mehdi Hosseini
MMMohammad H. Mahoor
Mohammad H. Mahoor
JHJason Wade Haas
Jason Wade Haas
JFJoseph R. Ferrantelli
Joseph R. Ferrantelli
ADAnne-Lise Dupuis
Anne-Lise Dupuis
Deed Eric HarrisonDeed Eric Harrison
Deed Eric Harrison
Background: The biomechanical analysis of spine and postural misalignments is important for surgical and non-surgical treatment of spinal pain. We investigated the examiner reliability of sagittal cervical alignment variables compared to the reliability and concurrent validity of computer vision algorithms used in the PostureRay® software 2024. Methods: A retrospective database of 254 lateral cervical radiographs of patients between the ages of 11 and 86 is studied. The radiographs include clearly visualized C1–C7 vertebrae that were evaluated by a human using the software. To evaluate examiner reliability and the concurrent validity of the trained CNN performance, two blinded trials of radiographic digitization were performed by an extensively trained expert user (US) clinician with a two-week interval between trials. Then, the same clinician used the trained CNN twice to reproduce the same measures within a 2-week interval on the same 254 radiographs. Measured variables included segmental angles as relative rotation angles (RRA) C1–C7, Cobb angles C2–C7, relative segmental translations (RT) C1–C7, anterior translation C2–C7, and absolute rotation angle (ARA) C2–C7. Data were remotely extracted from the examiner’s PostureRay® system for data collection and sorted based on gender and stratification of degenerative changes. Reliability was assessed via intra-class correlations (ICC), root mean squared error (RMSE), and R2 values. Results: In comparing repeated measures of the CNN network to itself, perfect reliability was found for the ICC (1.0), RMSE (0), and R2 (1). The reliability of the trained expert US was in the excellent range for all variables, where 12/18 variables had ICCs ≥ 0.9 and 6/18 variables were 0.84 ≤ ICCs ≤ 0.89. Similarly, for the expert US, all R2 values were in the excellent range (R2 ≥ 0.7), and all RMSEs were small, being 0.42 ≤ RMSEs ≤ 3.27. Construct validity between the expert US and the CNN network was found to be in the excellent range with 18/18 ICCs in the excellent range (ICCs ≥ 0.8), 16/18 R2 values in the strong to excellent range (R2 ≥ 0.7), and 2/18 in the good to moderate range (R2 RT C6/C7 = 0.57 and R2 Cobb C6/C7 = 0.64. The RMSEs for expert US vs. the CNN network were small, being 0.37 ≤ RMSEs ≤ 2.89. Conclusions: A comparison of repeated measures within the computer vision CNN network and expert human found exceptional reliability and excellent construct validity when comparing the computer vision to the human observer.

10 March 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PAPhilip Anthony Arnone
Philip Anthony Arnone
SKSteven J. Kraus
Steven J. Kraus
DFDerek S Farmen
Derek S Farmen
Douglas Frank LightstoneDouglas Frank Lightstone
Douglas Frank Lightstone
JJJason Orion Jaeger
Jason Orion Jaeger
CTChristine Theodossis
Christine Theodossis
Plain Radiography of the spine (PROTS) is utilized in many forms of healthcare including the chiropractic profession; however, the literature reflects conflicting opinions regarding utilization and value. Despite being an essential part of Evidence-Based Practice (EBP), few studies assess Doctors of Chiropractic (DCs) clinical opinions and experience regarding the utilization of (PROTS) in practice. In this study, DCs were surveyed regarding utilization of PROTS in practice. The survey was administered to an estimated 50,000 licensed DCs by email. A total of 4301 surveys were completed, of which 3641 were United States (US) DCs. The Clinician Opinion and Experience on Chiropractic Radiography (COECR) scale was designed to analyze survey responses. This valid and reliable scale demonstrated good internal consistency using confirmatory factor analysis and the Rasch model. Survey responses show that 73.3% of respondents utilize PROTS in practice and 26.7% refer patients out for PROTS. Survey responses show that, among US DCs, 91.9% indicate PROTS has value beyond identification of pathology, 86.7% indicate that PROTS is important regarding biomechanical analysis of the spine, 82.9% indicate that PROTS is vital to practice, 67.4% indicate that PROTS aids in measuring outcomes, 98.6% indicate the opinion that PROTS presents very low to no risk to patients, and 93.0% indicate that sharing clinical findings from PROTS studies with patients is beneficial to clinical outcomes. The results of the study indicated that based on clinical experience, the majority of DCs find PROTS to be vital to practice and valuable beyond the identification of red flags.