View All Publications
7 November 2022 in Pharmaceutics
Verified
Journal Article
Open access
PDF file
RCRachel Chapla
Rachel Chapla
KHKatherine Trang Huynh
Katherine Trang Huynh
CICarolyn Schutt Ibsen
Carolyn Schutt Ibsen
Targeted delivery of therapeutics to specific tissues is critically important for reducing systemic toxicity and optimizing therapeutic efficacy, especially in the case of cytotoxic drugs. Many strategies currently exist for targeting systemically administered drugs, and ultrasound-controlled targeting is a rapidly advancing strategy for externally-stimulated drug delivery. In this non-invasive method, ultrasound waves penetrate through tissue and stimulate gas-filled microbubbles, resulting in bubble rupture and biophysical effects that power delivery of attached cargo to surrounding cells. Drug delivery capabilities from ultrasound-sensitive microbubbles are greatly expanded when nanocarrier particles are attached to the bubble surface, and cargo loading is determined by the physicochemical properties of the nanoparticles. This review serves to highlight and discuss current microbubble–nanoparticle complex component materials and designs for ultrasound-mediated drug delivery. Nanocarriers that have been complexed with microbubbles for drug delivery include lipid-based, polymeric, lipid–polymer hybrid, protein, and inorganic nanoparticles. Several schemes exist for linking nanoparticles to microbubbles for efficient nanoparticle delivery, including biotin–avidin bridging, electrostatic bonding, and covalent linkages. When compared to unstimulated delivery, ultrasound-mediated cargo delivery enables enhanced cell uptake and accumulation of cargo in target organs and can result in improved therapeutic outcomes. These ultrasound-responsive delivery complexes can also be designed to facilitate other methods of targeting, including bioactive targeting ligands and responsivity to light or magnetic fields, and multi-level targeting can enhance therapeutic efficacy. Microbubble–nanoparticle complexes present a versatile platform for controlled drug delivery via ultrasound, allowing for enhanced tissue penetration and minimally invasive therapy. Future perspectives for application of this platform are also discussed in this review.

24 March 2021 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
KGKyle Thomas Gustafson
Kyle Thomas Gustafson
KHKatherine Trang Huynh
Katherine Trang Huynh
DHDaniel Heineck
Daniel Heineck
JBJesus Bueno
Jesus Bueno
AMAugusta Modestino
Augusta Modestino
SIStuart D. Ibsen
Stuart D. Ibsen
Tumor-secreted exosomes and other extracellular vesicles (EVs) in circulation contain valuable biomarkers for early cancer detection and screening. We have previously demonstrated collection of cancer-derived nanoparticles (NPs) directly from whole blood and plasma with a chip-based technique that uses a microelectrode array to generate dielectrophoretic (DEP) forces. This technique enables direct recovery of NPs from whole blood and plasma. The biomarker payloads associated with collected particles can be detected and quantified with immunostaining. Accurately separating the fluorescence intensity of stained biomarkers from background (BG) levels becomes a challenge when analyzing the blood from early-stage cancer patients in which biomarker concentrations are low. To address this challenge, we developed two complementary techniques to standardize the quantification of fluorescently immunolabeled biomarkers collected and concentrated at predictable locations within microfluidic chips. The first technique was an automated algorithm for the quantitative analysis of fluorescence intensity at collection regions within the chip compared to levels at adjacent regions. The algorithm used predictable locations of particle collection within the chip geometry to differentiate regions of collection and BG. We successfully automated the identification and removal of optical artifacts from quantitative calculations. We demonstrated that the automated system performs nearly the same as a human user following a standard protocol for manual artifact removal with Pearson's r-values of 0.999 and 0.998 for two different biomarkers (n = 36 patients). We defined a usable dynamic range of fluorescence intensities corresponding to 1 to 2000 arbitrary units (a.u.). Fluorescence intensities within the dynamic range increased linearly with respect to exposure time and particle concentration. The second technique was the implementation of an internal standard to adjust levels of biomarker fluorescence based on the relative collection efficiency of the chip. Use of the internal standard reduced variability in measured biomarker levels due to differences in chip-to-chip collection efficiency, especially at low biomarker concentrations. The internal standard did not affect linear trends between fluorescence intensity and exposure time. Adjustments using the internal standard improved linear trends between fluorescence intensity and particle concentration. The optical quantification techniques described in this paper can be easily adapted for other lab-on-a-chip platforms that have predefined regions of biomarker or particle collection and that rely on fluorescence detection.

10 July 2023 in Electrophoresis
Verified
Journal Article
Open access
RLRamona Luna
Ramona Luna
DHDaniel Heineck
Daniel Heineck
JHJuan Pablo Hinestrosa
Juan Pablo Hinestrosa
IDIrina Dobrovolskaia
Irina Dobrovolskaia
SHSean Hamilton
Sean Hamilton
SIStuart D. Ibsen
Stuart D. Ibsen
Dielectrophoresis (DEP) is a successful method to recover nanoparticles from different types of fluid. The DEP force acting on these particles is created by an electrode microarray that produces a nonuniform electric field. To apply DEP to a highly conducting biological fluid, a protective hydrogel coating over the metal electrodes is required to create a barrier between the electrode and the fluid. This protects the electrodes, reduces the electrolysis of water, and allows the electric field to penetrate into the fluid sample. We observed that the protective hydrogel layer can separate from the electrode and form a closed domed structure and that collection of 100 nm polystyrene beads increased when this occurred. To better understand this collection increase, we used COMSOL Multiphysics software to model the electric field in the presence of the dome filled with different materials ranging from low-conducting gas to high conducting phosphate-buffered saline fluids. The results suggest that as the electrical conductivity of the material inside the dome is reduced, the whole dome acts as an insulator which increases electric field intensity at the electrode edge. This increased intensity widens the high-intensity electric field factor zone resulting in increased collection. This informs how dome formation results in increased particle collection and provides insight into how the electric field can be intensified to the increase collection of particles. These results have important applications for increasing the recovery of biologically-derived nanoparticles from undiluted physiological fluids that have high conductance, including the collection of cancer-derived extracellular vesicles from plasma for liquid biopsy applications.

27 October 2024 in Cellular and Molecular Bioengineering
Verified
Journal Article
Open access
PDF file
MLMary K. Lowrey
Mary K. Lowrey
HDHolly Day
Holly Day
KSKevin J. Schilling
Kevin J. Schilling
KHKatherine Trang Huynh
Katherine Trang Huynh
CFCristiane M. Franca
Cristiane M. Franca
CICarolyn Schutt Ibsen
Carolyn Schutt Ibsen
Introduction: Coaxial 3D bioprinting has advanced the formation of tissue constructs that recapitulate key architectures and biophysical parameters for in-vitro disease modeling and tissue-engineered therapies. Controlling gene expression within these structures is critical for modulating cell signaling and probing cell behavior. However, current transfection strategies are limited in spatiotemporal control because dense 3D scaffolds hinder diffusion of traditional vectors. To address this, we developed a coaxial extrusion 3D bioprinting technique using ultrasound-responsive gene delivery bioinks. These bioink materials incorporate echogenic microbubble gene delivery particles that upon ultrasound exposure can sonoporate cells within the construct, facilitating controllable transfection. Methods: Phospholipid-coated gas-core microbubbles were electrostatically coupled to reporter transgene plasmid payloads and incorporated into cell-laden alginate bioinks at varying particle concentrations. These bioinks were loaded into the coaxial nozzle core for extrusion bioprinting with CaCl2 crosslinker in the outer sheath. Resulting bioprints were exposed to 2.25 MHz focused ultrasound and evaluated for microbubble activation and subsequent DNA delivery and transgene expression. Results: Coaxial printing parameters were established that preserved the stability of ultrasound-responsive gene delivery particles for at least 48 h in bioprinted alginate filaments while maintaining high cell viability. Successful sonoporation of embedded cells resulted in DNA delivery and robust ultrasound-controlled transgene expression. The number of transfected cells was modulated by varying the number of focused ultrasound pulses applied. The size region over which DNA was delivered was modulated by varying the concentration of microbubbles in the printed filaments. Conclusions: Our results present a successful coaxial 3D bioprinting technique designed to facilitate ultrasound-controlled gene delivery. This platform enables remote, spatiotemporally-defined genetic manipulation in coaxially bioprinted tissue constructs with important applications for disease modeling and regenerative medicine.

14 July 2025 in APL Bioengineering
Verified
Journal Article
Open access
KSKevin J. Schilling
Kevin J. Schilling
KHKatherine Trang Huynh
Katherine Trang Huynh
SSSean Speese
Sean Speese
CICarolyn Schutt Ibsen
Carolyn Schutt Ibsen
Immunofluorescence staining of cell proteins is essential to understanding biomolecular interactions within three-dimensional (3D) hydrogel cell cultures. However, the scaffold material limits passive diffusion of antibodies through thick 3D matrices, prolonging staining and washing steps and resulting in processing times that can last for several days. Microwave irradiation has previously been shown to enhance penetration of fixatives in a variety of soft tissues by increasing the rate of diffusion through the sample, yet it is unknown if microwave irradiation can improve immunofluorescence staining of cells in 3D hydrogel cultures. Here, we demonstrate a microwave-assisted immunostaining technique that rapidly labels cells within spheroid structures embedded within thick intact hydrogels. These results show that collagen-embedded breast epithelial spheroids can be efficiently labeled with primary antibodies in less than 3.5 h. We show significantly enhanced staining and greater depth penetration with microwave-assisted staining compared to conventional benchtop staining methods. We demonstrate staining of collagen-embedded breast cancer spheroids with complete staining achieved in less than 2.5 h via the microwave, which outperforms conventional staining techniques. Moreover, we demonstrate enhanced staining of spheroids embedded in basement membrane-derived Matrigel matrices with the microwave method compared to benchtop techniques. Finally, we directly compare 2-h microwave-assisted staining to conventional 15-h longform benchtop staining and show that microwave staining increases depth penetration and intensity of stains compared to the longform staining. This work develops a microwave-assisted staining protocol that provides a rapid and reproducible method to label a variety of cell types within various 3D hydrogel cell culture systems.

27 March 2025 in Particle & Particle Systems Characterization
Verified
Journal Article
Open access
KHKatherine Trang Huynh
Katherine Trang Huynh
RARandall Armstrong
Randall Armstrong
SSSean Speese
Sean Speese
CICarolyn Schutt Ibsen
Carolyn Schutt Ibsen
Lipid‐coated microbubbles are an important class of gene delivery vehicles activated by ultrasound to locally deliver their DNA payloads to cells. Negatively charged DNA is electrostatically loaded onto the positively charged surface of microbubbles that contain a cationic lipid shell. Characterizing the zeta potential of individual cationic microbubbles to determine a population distribution and how this is affected by DNA complexation is critical to maximize DNA loading and circulation time. Traditional zeta potential analysis provides an ensemble charge measurement for a particle population but cannot measure individual particles to determine a distribution. Here, single‐particle tracking microelectrophoresis technology is applied to measure zeta potentials of individual microbubbles synthesized with different ratios of 1,2‐distearoyl‐3‐trimethylammonium‐propane (DSTAP) cationic lipid as well as loaded with increasing amounts of DNA. Results show that at 0 mol% DSTAP all microbubbles are negatively charged, and at 10 mol% half are positive. All particles are positive at 20 mol% DSTAP but the population shifts to negative values upon incubation with 0.01 pg DNA/microbubble. Analyzing zeta potential on the individual microbubble level is a powerful tool to understand DNA loading across a population of microbubbles and enables microbubble surface charge and nucleic acid loading optimization for delivery applications.