This paper presents a new method to establish the leakage inductances of AC machine stator winding using a numerical analyzing program based on the finite elements method. The 3D numerical analysis is used to determine the end winding leakage inductance. In order to eliminate the magnetic flux present in the space normally occupied by the rotor, when the rotor is removed, the air from the rotor space is replaced with a very low relative magnetic permeability (10 -6 ) material. The results obtained are compared to those obtained by another method of numerical analysis, and with those calculated analytically. For one of the models, the results are compared to the results obtained experimentally as well.

18 July 2024 in Energies
Verified
Journal Article
Open access
PDF file
Olivian ChiverOlivian Chiver
Olivian Chiver
ISIoan Radu Sugar
Ioan Radu Sugar
Liviu NeamtLiviu Neamt
Liviu Neamt
Hybrid electric vehicles (HEVs) are perceived as a first step toward the future of sustainable transport. Of course, battery electric vehicles (EVs) are currently ideal for what is wanted in the future of transport. However, the lack of infrastructure for these vehicles makes many potential users choose hybrid vehicles. This paper presents an analysis of the influence of hybrid vehicle engines and electric motors on their performance. Three engines with slightly different power levels and similar characteristics were considered for the configured models. Additionally, two electric motors with very different power levels, but a very close maximum continuous torque were used in our models. One was an induction motor and the other was a permanent magnet synchronous motor. The ADVISOR software was used for vehicle configuration and simulation. Series and parallel hybrid vehicles were considered. The main dynamic performances and the fuel consumption rates of the two driving cycles were compared for the configured models. Three conventional models with the same engines used in HEVs were also simulated for reference. The results highlight that, in the case of HEVs, the choice of a combination engine/electric motor is crucial for obtaining the best compromise between a dynamic performance and a low fuel consumption and, implicitly, a low negative impact on the environment.

14 October 2021 in IEEE Access
Verified
Journal Article
Open access
Liviu NeamtLiviu Neamt
Liviu Neamt
Olivian ChiverOlivian Chiver
Olivian Chiver
To balance the potential distribution on the surface of a substation, an equal spacing arrangement of the grounding grid conductors is not an economical solution. The implementable solution is an unequal placement of its constituent elements. The design methodologies of such a configuration are complex and require computer-assisted numerical analysis. This paper proposes and validates a simple method of arranging the conductors of the grounding grid that guarantees the reduction of touch and step voltages, ensures the efficiency of the material used and has no limitations on its applicability for atypical substation surfaces (too large or too small), respectively for few or many parallel conductors. The proposed algorithm is analyzed, through the CYMGRD Substation Grounding Program, compared to the technologies currently applied, for the substation grounding grid presented as an example in the IEEE Guide for Safety in AC Substation Grounding 80 ™ -2013 standard.

1 October 2018
Verified
Conference Paper
Closed access
Olivian ChiverOlivian Chiver
Olivian Chiver
LNLiviu Neamt
Liviu Neamt
BCBarz Cristian
Barz Cristian
EPEleonora Pop
Eleonora Pop
This paper investigates the three phase squirrel cage asynchronous machine in the autonomous (isolated) generator regime. Both transient and steady state performances with load and an excitation capacitor bank are presented. In order to perform this, a Matlab/Simulink model of the generator was done. Then the modeled machine was tested in the laboratory, comparing the results of the simulations with the experimental ones.

1 June 2015
Verified
Conference Paper
Closed access
Olivian ChiverOlivian Chiver
Olivian Chiver
Liviu NeamtLiviu Neamt
Liviu Neamt
Oliviu MateiOliviu Matei
Oliviu Matei
This paper deals with sudden short-circuit transient regimes of a three-phase salient poles synchronous generator. The three-phase, two-phase and single-phase transient short-circuits of a synchronous generator with two pole pairs, 1500 rev/s, are studied analytically, by finite elements analysis (FEA) and experimentally. Analytic study was performed using Mathcad and FEA was performed using MagNet software from Infolytica. In order to record the transient currents a Fluke 435 apparatus was used in laboratory. Finally, the results obtained by the three methods are discussed.

1 October 2014
Verified
Conference Paper
Closed access
Liviu NeamtLiviu Neamt
Liviu Neamt
Olivian ChiverOlivian Chiver
Olivian Chiver
CBCristian Barz
Cristian Barz
CCCristinel Costea
Cristinel Costea
ZEZoltan Erdei
Zoltan Erdei
The paper presents some considerations about power system grounding based on analytical computation, Finite Element Analysis (FEA) combined with neural network. There are studied vertical rods buried on different depth in homogenous and double-layer soil. First, the analytical solutions are compared with the numerical results for certifying the FEA settings then, different configurations for electrodes in different soil structures were analyzed and the results were interpreted using neuronal network. This approach offer solutions for any configurations in less time than FEA alone.