Ariel Berlinski

Prof. Ariel Berlinski

orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Respiratory Care
Verified
Journal Article
Open access
PDF file
ABAriel Berlinski
Ariel Berlinski
JWJ Randy Willis
J Randy Willis
BACKGROUND: The type of aerosol generator and the position in the ventilator circuit are crucial to determine aerosol delivery during mechanical ventilation. We compared lung deposition of albuterol aerosols generated by 4 different nebulizers placed in-line in 4 different positions in a pediatric ventilator model. METHODS: Two brands of continuously operated jet nebulizer (6 L/min, oxygen), an ultrasonic, and a vibrating mesh were compared when placed at the ventilator, the humidifier, the Y-piece, and 30 cm before the Y-piece. The jet, ultrasonic, and vibrating mesh nebulizers were operated for 5, 15, and 15 min, respectively. The tested solutions contained 2.5 mg, 5.0 mg, and 7.5 mg of albuterol sulfate. The ventilator settings were: pressure-regulated volume control mode, tidal volume 200 mL, breathing frequency 20 breaths/min, PEEP 5 cm H2O, FIO2 0.4, inspiratory time 0.75 s, bias flow 2 L/min, and heater 37°C. The circuit was connected in series to a 5.5 mm cuffed endotracheal tube, a deposition filter, and a lung model. Albuterol was measured by spectrophotometry. RESULTS: Intra-device comparison: the jet and vibrating mesh nebulizers performed best at either the ventilator or humidifier, and worst at the Y-piece. The ultrasonic nebulizer performed best at the humidifier and worst at the Y-piece. Inter-device comparison: the vibrating mesh nebulizer outperformed both jet nebulizers at all tested positions, and the ultrasonic nebulizer when placed at either the ventilator or the humidifier. Lung deposition increased for the jet and ultrasonic nebulizers, but not for vibrating mesh nebulizer, when increasing the loading volume while maintaining the nominal dose. CONCLUSIONS: The vibrating mesh nebulizer was the most efficient device. The nebulizers were more efficient when placed at either the ventilator or the humidifier, and less efficient when placed at either the Y-piece or 30 cm from the Y-piece. These conclusions are valid for the tested conditions. Data regarding optimization of operating conditions should not be extrapolated among nebulizers of different operating principles.

2 July 2013 in Respiratory Care
Verified
Journal Article
Open access
PDF file
JXJinxiang Xi
Jinxiang Xi
XSXiuhua Si
Xiuhua Si
YZYue Zhou
Yue Zhou
JKJongWon Kim
JongWon Kim
ABAriel Berlinski
Ariel Berlinski
BACKGROUND: The human respiratory airway undergoes dramatic growth during infancy and childhood, which induces substantial variability in air flow pattern and particle deposition. However, deposition studies have typically focused on adult subjects, the results of which cannot be readily extrapolated to children. We developed models to quantify the growth of human nasal-laryngeal airways at early ages, and to evaluate the impact of that growth on breathing resistance and aerosol deposition. METHODS: Four image-based nasal-laryngeal models were developed from 4 children, ages 10 days, 7 months, 3 years, and 5 years, and were compared to a nasal-laryngeal model of a 53-year-old adult. The airway dimensions were quantified in terms of different parameters (volume, cross-section area, and hydraulic diameter) and of different anatomies (nose, pharynx, and larynx). Breathing resistance and aerosol deposition were computed using a high-fidelity fluid-particle transport model, and were validated against the measurements made with the 3-dimensional models fabricated from the same airway computed tomography images. RESULTS: Significant differences in nasal morphology were observed among the 5 subjects, in both morphology and dimension. The turbinate region appeared to experience the most noticeable growth during the first 5 years of life. The nasal airway volume ratios of the 10-day, 7-month, 3-year, and 5-year-old subjects were 6.4%, 18.8%, 24.2%, and 40.3% that of the adult, respectively. Remarkable inter-group variability was observed in air flow, pressure drop, deposition fraction, and particle accumulation. The computational fluid dynamics predicted pressure drops and deposition fractions were in close agreement with in vitro measurements. CONCLUSIONS: Age effects are significant in both breathing resistance and micrometer particle deposition. The image/computational-fluid-dynamics coupled method provides an efficient and effective approach in understanding patient-specific air flows and particle deposition, which have important implications in pediatric inhalation drug delivery and respiratory disorder diagnosis.

1 July 2015 in Respiratory Care
Verified
Journal Article
Closed access
KTKatia K El Taoum
Katia K El Taoum
JXJinxiang Xi
Jinxiang Xi
JKJongWong Kim
JongWong Kim
ABAriel Berlinski
Ariel Berlinski
BACKGROUND: Infants and young children are obligate nose breathers; therefore, a transnasal route seems the logical delivery method of inhaled aerosols. The efficiency of aerosol delivery depends on several factors, such as interface, type of nebulizer, and patient age and breathing pattern. We hypothesized that the use of a vibrating mesh nebulizer, a tight-fitting face mask, and a head model and breathing pattern of an older child would result in a higher lung dose. We also hypothesized that the use of an anatomically correct model would more accurately reflect lung dose than models that do not include airways. METHODS: A model comprising a breathing simulator and an anatomically correct model of a 7-month-old infant and a 5-y-old child with an interposed collection filter (lung dose) were used. Breathing patterns of a newborn, infant, and child were used with 7 interfaces. A continuous output and a vibrating mesh nebulizer were loaded with albuterol sulfate solution (5 mg/3.5 mL) and operated for 5 min. Albuterol mass was determined via spectrophotometer (276 nm). RESULTS: Lung dose varied between 0 and 3%. The jet nebulizer was more efficient than the vibrating mesh nebulizer. The front-loaded mask was the most efficient interface. We also found that higher tidal volumes were associated with higher lung doses and that the use of a larger airway model resulted in a lower lung dose. Finally, the model showed a good correlation with in vivo data and rendered lung doses severalfold lower than previous data obtained with oral models. CONCLUSIONS: Careful pairing of the aerosol generator and interface is very important during transnasal aerosol delivery.

1 June 2017 in Respiratory Care
Verified
Journal Article
Open access
PDF file
ABAriel Berlinski
Ariel Berlinski
Inhaled medications are the mainstay of therapy for many pediatric pulmonary diseases. Device and delivery technique selection is key to improving lung deposition of inhaled drugs. This paper will review the subject in relationship to several pediatric clinical situations: acute pediatric asthma, transnasal aerosol delivery, delivery through tracheostomies, and delivery during noninvasive and invasive mechanical ventilation. This review will focus on the pediatric age group and will not include neonates.

12 May 2015 in Respiratory Care
Verified
Journal Article
Open access
PDF file
ABAriel Berlinski
Ariel Berlinski
JWJ Randy Willis
J Randy Willis
BACKGROUND: Optimization of factors affecting aerosol delivery during mechanical ventilation in the pediatric population is important. We hypothesized that increasing the tidal volume (V T ), using a vibrating mesh nebulizer, and placing the nebulizer at the ventilator would increase lung dose/delivery efficiency. METHODS: Continuous-output jet and vibrating mesh nebulizers loaded with albuterol (2.5 mg/3 mL) were compared when placed before the Y-piece and at the ventilator. The model consisted of a ventilator operated in pressure-regulated volume control ventilation mode at a breathing frequency of 20 breaths/min, PEEP of 5 cm H 2 O, F IO2 of 0.4, inspiratory time of 0.75 s, and bias flow of 0.5 L/min with a humidifier (37 ± 1.5°C) and an adult heated-wired circuit. V T values of 100, 150, 200, and 300 mL were studied. The circuit was connected in series to a 5.5-mm inner diameter endotracheal tube with a filter (lung dose) interposed between them. Delivery efficiency was calculated as a percentage of the nominal dose captured on the filter. Albuterol content was analyzed by spectrophotometry (276 nm). RESULTS: No differences in lung dose/delivery efficiency were found at different V T values for the jet nebulizer (both positions) and the vibrating mesh nebulizer (ventilator). Lung dose/delivery efficiency was higher ( P < .02) at a V T of 100 mL compared with the other volumes tested. The vibrating mesh nebulizer had higher lung dose/delivery efficiency compared with the jet nebulizer only when placed before the Y-piece. Moving the nebulizers from before the Y-piece to the ventilator increased lung dose/delivery efficiency for all conditions tested except the vibrating mesh nebulizer at a V T of 100 mL ( P = .36). CONCLUSIONS: Optimization of inhaled drug delivery during pediatric mechanical ventilation should include careful selection of the type of delivery device and its placement in the ventilator circuit. Increasing V T during nebulization did not increase lung dose/delivery efficiency.

9 February 2010 in Pediatric Pulmonology
Verified
Journal Article
Closed access
PDF file
ACAlma Chavez
Alma Chavez
AMAndy McCracken
Andy McCracken
ABAriel Berlinski
Ariel Berlinski