Maciej Cieplak

Dr. Maciej Cieplak

Institute of Physical Chemistry PAS, Kasprzaka 44/52, 01-224 Warsaw, Poland
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2016 in Trends in Biotechnology
Verified
Journal Article
Closed access
MCMaciej Cieplak
Maciej Cieplak
WKWlodzimierz Kutner
Wlodzimierz Kutner

1 April 2018 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MDMarcin Dabrowski
Marcin Dabrowski
PLPatrycja Lach
Patrycja Lach
MCMaciej Cieplak
Maciej Cieplak
WKWlodzimierz Kutner
Wlodzimierz Kutner

1 December 2015 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
MCMaciej Cieplak
Maciej Cieplak
KSKatarzyna Szwabinska
Katarzyna Szwabinska
MSMarta Sosnowska
Marta Sosnowska
BCBikram K.C. Chandra
Bikram K.C. Chandra
PBPaweł Borowicz Paweł Borowicz
Paweł Borowicz Paweł Borowicz
WKWlodzimierz Kutner
Wlodzimierz Kutner

22 November 2020 in ACS Sensors
Verified
Journal Article
Open access
JKJakub Kalecki
Jakub Kalecki
ZIZofia Iskierko
Zofia Iskierko
MCMaciej Cieplak
Maciej Cieplak
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
In this Review, we have summarized recent trends in protein template imprinting. We emphasized a new trend in surface imprinting, namely, oriented protein immobilization. Site-directed proteins were assembled through specially selected functionalities. These efforts resulted in a preferably oriented homogeneous protein construct with decreased protein conformation changes during imprinting. Moreover, the maximum functionality for protein recognition was utilized. Various strategies were exploited for oriented protein immobilization, including covalent immobilization through a boronic acid group, metal coordinating center, and aptamer-based immobilization. Moreover, we have discussed the involvement of semicovalent as well as covalent imprinting. Interestingly, these approaches provided additional recognition sites in the molecular cavities imprinted. Therefore, these molecular cavities were highly selective, and the binding kinetics was improved.

1 August 2019 in Current Opinion in Electrochemistry
Verified
Journal Article
Open access
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
ACALVARO GARCIA CRUZ
ALVARO GARCIA CRUZ
MCMaciej Cieplak
Maciej Cieplak
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta
WKWlodzimierz Kutner
Wlodzimierz Kutner

1 August 2017 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
MDMarcin Dabrowski
Marcin Dabrowski
MCMaciej Cieplak
Maciej Cieplak
PSPiyush Sindhu Sharma
Piyush Sindhu Sharma
PBPaweł Borowicz Paweł Borowicz
Paweł Borowicz Paweł Borowicz
Krzysztof NoworytaKrzysztof Noworyta
Krzysztof Noworyta
WKWlodzimierz Kutner
Wlodzimierz Kutner
Nanostructured artificial receptor materials with unprecedented hierarchical structure for determination of human serum albumin (HSA) are designed and fabricated. For that purpose a new hierarchical template is prepared. This template allowed for simultaneous structural control of the deposited molecularly imprinted polymer (MIP) film on three length scales. A colloidal crystal templating with optimized electrochemical polymerization of 2,3'-bithiophene enables deposition of an MIP film in the form of an inverse opal. Thickness of the deposited polymer film is precisely controlled with the number of current oscillations during potentiostatic deposition of the imprinted poly(2,3'-bithiophene) film. Prior immobilization of HSA on the colloidal crystal allows formation of molecularly imprinted cavities exclusively on the internal surface of the pores. Furthermore, all binding sites are located on the surface of the imprinted cavities at locations corresponding to positions of functional groups present on the surface of HSA molecules due to prior derivatization of HSA molecules with appropriate functional monomers. This synergistic strategy results in a material with superior recognition performance. Integration of the MIP film as a recognition unit with a sensitive extended-gate field-effect transistor (EG-FET) transducer leads to highly selective HSA determination in the femtomolar concentration range.