Background: Rotator cuff (RC) tendinopathy is one of the most common causes of shoulder pain. Platelet-rich plasma (PRP) has been frequently used in clinical scenarios, but its efficacy remains inconsistent. Purpose: To investigate the different responses of human tenocytes from torn RCs to leukocyte-rich PRP (LR-PRP) and leukocyte-poor PRP (LP-PRP) in a 2-chamber coculture device. Study Design: Controlled laboratory study. Methods: PRP was prepared using different platelet and leukocyte concentrations according to 5 groups: (1) LR-PRP with 5000 platelets/µL, (2) LR-PRP with 10,000 platelets/µL, (3) LP-PRP with 5000 platelets/µL, (4) LP-PRP with 10,000 platelets/µL, and (5) control with only culture medium supplementation and without PRP stimulation. Platelet-derived growth factor–AB (PDGF-AB) and transforming growth factor–β1 (TGF-β1) were measured in LR-PRP and LP-PRP via enzyme-linked immunosorbent assay. Microscopy, water-soluble tetrazolium salt assay, and quantitative real-time polymerase chain reaction were used to investigate the morphology, proliferation, and gene expression of RC tenocytes exposed to different PRP formulations. Data were collected from at least 3 independent measurements. The results were analyzed via 1-way analysis of variance, followed by the post hoc Bonferroni test. Results: The ratio of leukocytes to 5000 platelets/µL was 29.5 times higher in LR-PRP than in LP-PRP ( P < .05). In the 5000 platelets/µL groups, the levels of TGF-β1 and PDGF-AB were both significantly higher in LR-PRP versus LP-PRP (TGF-β1: 367.0 ± 16.5 vs 308.6 ± 30.3 pg/mL, respectively [ P = .043]; PDGF-AB: 172.1 ± 1.8 vs 94.1 ± 4.2 pg/mL, respectively [ P < .001]). Compared with the control group, RC tenocyte proliferation was 1.42 ± 0.01 and 1.41 ± 0.03 times higher in the LR-PRP groups with 5000 platelets/µL and 10,000 platelets/µL, respectively ( P < .05). The expression of tenocyte-related genes was higher in tenocytes cultured in LR-PRP. Conclusion: Both the LR-PRP groups with 5000 platelets/µL and 10,000 platelets/µL induced more growth factor release and increased RC tenocyte proliferation than did the LP-PRP groups. Clinical Relevance: In RC repair, LR-PRP may be better than LP-PRP for increasing the proliferation of tenocytes.
16 October 2017 in Journal of Orthopaedic Surgery and Research
Local injections of anesthetics, NSAIDs, and corticosteroids for tendinopathies are empirically used. They are believed to have some cytotoxicity toward tenocytes. The maximal efficacy dosages of local injections should be determined. A commercial 2D microfluidic xCELLigence system had been developed to detect real-time cellular proliferation and their responses to different stimuli and had been used in several biomedical applications. The purpose of this study is to determine if human tenocytes can successfully proliferate inside xCELLigence system and the result has high correlation with conventional cell culture methods in the same condition. First passage of human tenocytes was seeded in xCELLigence and conventional 24-well plates. Ketorolac tromethamine, bupivacaine, methylprednisolone, and betamethasone with different concentrations (100, 50, and 10% diluted of clinical usage) were exposed in both systems. Gene expression of type I collagen, type III collagen, tenascin-C, decorin, and scleraxis were compared between two systems. Human tenocytes could proliferate both in xCELLigence and conventional cell culture systems. Cytotoxicity of each drug revealed dose-dependency when exposed to tenocytes in both systems. Significance was found between groups. All the four drugs had comparable cytotoxicity in their 100% concentration. When 50% concentration was used, betamethasone had a relatively decreased cytotoxicity among them in xCELLigence but not in conventional culture. When 10% concentration was used, betamethasone had the least cytotoxicity. Strong and positive correlation was found between cell index of xCELLigence and result of WST-1 assay (Pearson’s correlation [r] = 0.914). Positive correlation of gene expression between tenocytes in xCELLigence and conventional culture was also observed. Type I collagen: [r] = 0.823; type III collagen: [r] = 0.899; tenascin-C: [r] = 0.917; decorin: [r] = 0.874; and scleraxis: [r] = 0.965. Human tenocytes could proliferate inside xCELLigence system. These responses varied when tenocytes were exposed to different concentrations of ketorolac tromethamine, bupivacaine, methylprednisolone, and betamethasone. The result of cell proliferation and gene expression of tenocytes in both xCELLigence and conventional culture system is strongly correlated. xCELLigence culture system may replace conventional cell culture, which made real-time tenocyte proliferation monitoring possible.
31 July 2018 in Journal of Orthopaedic Surgery and Research
The role of surgical fixation of ulnar styloid fractures remains a subject of debate. The purpose of this study was to compare the surgical outcomes following early and late intervention. We retrospectively reviewed 28 patients who underwent surgical repair for unilateral ulnar styloid fractures with distal radioulnar instability between 2004 and 2014. Surgical fixation was performed within 3 months of injury in 13 patients (group A) and beyond 3 months in 15 patients (group B). Patient characteristics and functional outcomes were compared between the two groups. The outcome survey consisted of QuickDASH score, grip strength, range of motion, pain score based on the visual analog scale, and surgical complications. Descriptive statistics were calculated for key variables. A p value of < 0.01 was considered statistically significant. Patient characteristics including age, sex, injured side, dominant side injury, and concomitant distal radius fracture showed no significant differences between the two groups. Time to surgery averaged 1.1 months in group A and 12.3 months in group B. Significantly better outcomes were found in group A than in group B, including QuickDASH scores (4.4 ± 5.9 vs. 12.9 ± 9.9) and grip strength (37.4 ± 5.1 vs. 29.1 ± 5.9 kg). Significantly better range of motion was found in group A than in group B with respect to supination (81.9° ± 4.3° vs. 75° ± 8.5°), extension (84.6 ± 4.3 vs. 76.7 ± 6.5), and flexion (80.4° ± 3.8° vs. 72° ± 4.1°). The difference was not significant in case of pronation (78.8° ± 3° vs. 74.3° ± 5.9°) and with respect to pain scores (0.6 ± 0.7 vs. 1.3 ± 1). Both osseous and soft tissue lesions need to be fully addressed in ulnar styloid fractures. Early detection and surgical repair yielded better outcomes. Higher complication rates in late-treated fractures show that surgeons should select surgical candidates and modalities properly.
Background: The timing to start passive or active range of motion (ROM) after arthroscopic rotator cuff repair remains unclear. This systematic review and meta-analysis evaluated early versus delayed passive and active ROM protocols following arthroscopic rotator cuff repair. The aim of this study is to systematically review the literature on the outcomes of early active/passive versus delayed active/passive postoperative arthroscopic rotator cuff repair rehabilitation protocols. Methods: A systematic review and meta-analysis of randomized controlled trials (RCTs) published up to April 2022 comparing early motion (EM) versus delayed motion (DM) rehabilitation protocols after arthroscopic rotator cuff repair for partial and full-thickness tear was conducted. The primary outcome was range of motion (anterior flexion, external rotation, internal rotation, abduction) and the secondary outcomes were Constant-Murley score (CMS), Simple Shoulder Test Score (SST score) and Visual Analogue Scale (VAS). Results: Thirteen RCTs with 1,082 patients were included in this study (7 RCTs for early passive motion (EPM) vs. delayed passive motion (DPM) and 7 RCTs for early active motion (EAM) vs. delayed active motion (DAM). Anterior flexion (1.40, 95% confidence interval (CI), 0.55–2.25) and abduction (2.73, 95%CI, 0.74–4.71) were higher in the EPM group compared to DPM. Similarly, EAM showed superiority in anterior flexion (1.57, 95%CI, 0.62–2.52) and external rotation (1.59, 95%CI, 0.36–2.82), compared to DAM. There was no difference between EPM and DPM for external rotation, retear rate, CMS and SST scores. There was no difference between EAM and DAM for retear rate, abduction, CMS and VAS. Conclusion: EAM and EPM were both associated with superior ROM compared to the DAM and DPM protocols. EAM and EPM were both safe and beneficial to improve ROM after arthroscopic surgery for the patients with small to large sized tears.
20 April 2017 in Journal of Orthopaedic Surgery and Research
Rotator cuff tears are very common and their incidence increases with age. Shoulder ultrasonography has recently gained popularity in detecting rotator cuff tears because of its efficiency, cost-effectiveness, time-saving, and real-time nature of the procedure. Well-trained orthopedic surgeons may utilize shoulder ultrasonography to diagnose rotator cuff tears. The wait time of patients planned to have shoulder MRI (magnetic resonance imaging) to rule in rotator cuff tears may decrease after orthopedic surgeon start doing shoulder ultrasonography as a screening tool for that. Patients with rotator cuff tears may be detected earlier by ultrasonography and have expedited surgical repair. The efficacy in determination of rotator cuff tears will also increase. Patients were retrospectively reviewed from January 2007 to December 2012. They were divided into 2 groups: Ultrasound (-) group and the Ultrasound (+) group. Age, gender, wait time from outpatient department (OPD) visit to MRI exam, MRI exam to operation (OP), and OPD visit to OP, patient number for MRI exam, and number of patients who finally had rotator cuff repair within two groups were compared. The wait time of OPD visit to OP and MRI to OP in patients who received shoulder ultrasonography was significantly less than that in patients did not receive shoulder ultrasonography screening. Only 23.8% of the patients with a suspected rotator cuff injury undergone arthroscopic rotator cuff repair before ultrasonography was applied as a screening tool. The percentage increased to 53.6% after orthopedic surgeon started using ultrasonography as a screening tool for rotator cuff tears. Office-based shoulder ultrasound examination can reduce the wait time for a shoulder MRI. The efficacy of determination of rotator cuff tears will also increase after the introduction of shoulder ultrasonography.
18 September 2019 in Journal of Orthopaedic Research