Beata Palczynska

Dr. Beata Palczynska

Gdańsk University of Technology, Gdańsk, Pomorskie, Poland
orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2018
Verified
Conference Paper
Closed access
KNKrystyna Maria Noga
Krystyna Maria Noga
BPBeata Palczynska
Beata Palczynska
This paper presents the simulation laboratory platform, including the advanced examples of the NI Multisim environment assigned for an electronic engineering education, a digital signal processing especially. A methodology of teaching of the digital signal processing for both electrical and electronic specializations requires the use a virtual platform, that creates a bridge between theoretical lectures in classes and practical application in the design, prototyping, and testing of electrical and electronic circuits in laboratories. In the article, exemplary solutions of the Multisim applications used in classes of the digital signal processing during the engineering courses at the Faculty of Electrical Engineering in Gdynia Maritime University are presented and discussed. The application of the presented teaching methodology gives excellent didactic results. It indicates that the experimental teaching based on development platforms such as the Multisim provides students with a comprehensive and creative approach to learning and knowledge transfer during the theoretical lectures. It is also a good training for work with real electrical and electronic systems.

11 May 2020 in Sensors
Verified
Journal Article
Open access
PDF file
BPBeata Palczynska
Beata Palczynska
RMRomuald Masnicki
Romuald Masnicki
JMJanusz Mindykowski
Janusz Mindykowski
The contribution of this paper is to show the opportunities for using the compressive sensing (CS) technique for detecting harmonics in a frequency sparse signal. The signal in a ship’s electrical network, polluted by harmonic distortions, can be modeled as a superposition of a small number of sinusoids and the discrete Fourier transform (DFT) basis forms its sparse domain. According to the theory of CS, a signal may be reconstructed from under-sampled incoherent linear measurements. This paper highlights the use of the discrete Radon transform (DRT) techniques in the CS scheme. In the reconstruction algorithm section, a fast algorithm based on the inverse DRT is presented, in which a few randomly sampled projections of the input signal are used to correctly reconstruct the original signal. However, DRT requires a very large set of measurements that can defeat the purpose of compressive data acquisition. To acquire the wideband data below the Nyquist frequency, the K-rank-order filter is applied in the sparse transform domain to extract the most significant components and accelerate the convergence of the solution. While most CS research efforts focus on random Gaussian measurements, the Bernoulli matrix with different values of the probability of ones is applied in the presented algorithm. Preliminary results of numerical simulation confirm the effectiveness of the algorithm used, but also indicate its limitations. A significant advantage of the proposed approach is the speed of analysis, which uses fast Fourier transform (FFT) and inverse FFT (IFFT) algorithms widely available in programming environments. Moreover, the data processing algorithm is quite simple, and therefore memory usage and burden of the data processing load are relatively low.

21 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
RMRomuald Masnicki
Romuald Masnicki
JMJanusz Mindykowski
Janusz Mindykowski
BPBeata Palczynska
Beata Palczynska
The paper deals with the important challenges in terms of electricity transmission by means of underground cable lines. The power cable’s performance is characterized by an ampacity that represents its maximum electric current-carrying capacity. The ampacity of power cables depends on their ability to diffuse the heat generated by the current flow into the environment. In the performed research, the analysis of the efficiency of heat dissipation from the cable is based on the measurement of temperatures at selected points in individual sections of the cable. As a consequence, the proposed test stand and applied research methodology are vital for the experimental evaluation of the analyzed thermal phenomena in the investigated underground cable lines. The research program covers an in-depth analysis based on the results related to the vital parameters of the investigated cable. The experimental methodology was used to analyze the influence of the properties of the medium surrounding the cable on its temperature, and thus on the ampacity of the cable. A novelty of this paper concerns the carrying out of the experimental laboratory research with actual measurements of the temperature distribution in specific points of the casing pipe based on the original test stand. The paper presents the novel concept of the developed stand for testing heat dissipation from the cable in a casing pipe with pipe sections filled with various media, equipped with a power supply system ensuring easy control of the power dissipated in the cable. The preliminary results of the comparative tests, in which the temperature distribution in the sections of the casing pipes was recorded, indicate that the findings are satisfactorily consistent with the assumptions related to the purpose of the research. The use of appropriate materials surrounding the cable contributes to more effective heat dissipation, and as it has been shown for the examined case in originally planned and conducted tests, it can lower the cable temperature by more than 20 °C, contributing to a significant increase in the ampacity of the cable. For example, it was recorded that for different media filling the pipes, the cable reached 30 °C with different currents flowing through cable of 60 A and 120 A, respectively.

1 November 2010 in International Journal of Electronics and Telecommunications
Verified
Journal Article
Closed access
PDF file
KNKrystyna Noga
Krystyna Noga
BPBeata Palczynska
Beata Palczynska
Overview of Fading Channel Modeling: VisSim and LabVIEW based approaches are proposed and implemented to demonstrate fading in the communication systems. The introduction to fading, models for flat fading like Rayleigh, Weibull, Nakagami-mand the results of simulations are presented.

12 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
RMRomuald Masnicki
Romuald Masnicki
JMJanusz Mindykowski
Janusz Mindykowski
BPBeata Palczynska
Beata Palczynska
DWDawid Werner
Dawid Werner
Disruptions in power quality have a negative impact on many energy consumers. These include lighting, where interference manifests itself, among others, in the form of light flickering. The article presents phenomena accompanying the operation of modern light sources against the background of exemplary results of studies on the flicker of conventional light sources, such as incandescent or fluorescent lamps. The flickering effect of light generated in modern lamps can occur under stable voltage conditions in the supply network. The main subjects of the conducted research were solid-state light sources—light-emitting diode (LED) lamps, currently available on the lighting market. To assess the effects of these phenomena, it is necessary to use measures other than those traditionally used. The method used allows for the measurement of flicker resulting from both power supply disturbances and the properties of modern light sources. Using the developed measurement system, it is possible to record temporal changes in flicker coefficients resulting from, for example, changing supply voltage conditions. Due to the possibility of flickering light from sources offered by different manufacturers, as shown by research, it is advisable to carry out measurements at the place of use of the lighting.

1 May 2007
Verified
Conference Paper
Closed access
BPBeata Palczynska
Beata Palczynska
LSLudwik Spiralski
Ludwik Spiralski
JWJacek Wyszkowski
Jacek Wyszkowski
The results of electromagnetic field measurements of bow thruster drive with frequency converter, made during stay of the vessel in the port, are performed in this paper. These experiments are the one of the steps of the bigger research project, which leads to evaluation of electromagnetic field intensity onboard research-training vessel m/v "Horyzont II". Due to the analysis of measurements results, the level of electromagnetic field intensity was evaluated, in reference to the standards, which take into account the people protection against the excessive emission of electromagnetic field. In the investigated environment, there is a low intensity of electric field. But in frequency range from 5 Hz to 400 kHz, the high intensity of magnetic field is observed. The area of high magnetic field intensity was localized, close to the cable supplying the bow thruster motor, near to the motor junction box.