The design and structure of a self-assembly modular robot (Sambot) are presented in this paper. Each module has its own autonomous mobility and can connect with other modules to form robotic structures with different manipulation abilities. Sambot has a versatile, robust, and flexible structure. The computing platform provided for each module is distributed and consists of a number of interlinked microcontrollers. The interaction and connectivity between different modules is achieved through infrared sensors and Zigbee wireless communication in discrete state and control area network bus communication in robotic configuration state. A new mechanical design is put forth to realize the autonomous motion and docking of Sambots. It is a challenge to integrate actuators, sensors, microprocessors, power units, and communication elements into a highly compact and flexible module with the overall size of 80 mm × 80 mm × 102 mm. The work describes represents a mature development in the area of self-assembly distributed robotics.
1 September 2009 in IEEE Transactions on Information Technology in Biomedicine
In this paper, a novel time division multiple access based MAC protocol designed for body sensor networks (BSNs) is presented. H-medium-access control (MAC) aims to improve BSNs energy efficiency by exploiting heartbeat rhythm information, instead of using periodic synchronization beacons, to perform time synchronization. Heartbeat rhythm is inherent in every human body and observable in various biosignals. Biosensors in a BSN can extract the heartbeat rhythm from their own sensory data by detecting waveform peaks. All rhythms represented by peak sequences are naturally synchronized since they are driven by the same source, i.e., the heartbeat. Following the rhythm, biosensors can achieve time synchronization without having to turn on their radio to receive periodic timing information from a central controller, so that energy cost for time synchronization can be completely eliminated and the lifetime of the network can be prolonged. An active synchronization recovery scheme is also developed, including two resynchronization approaches. The algorithms are simulated using the discrete event simulator OMNet ++ with real-world data from the Massachusetts Institute of Technology-Boston's Beth Israel Hospital multiparameter database Multiparameter Intelligent Monitoring for Intensive Care. The results show that H-MAC can prolong the network life dramatically.
12 July 2012 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
High-resolution, real-time data obtained by human motion tracking systems can be used for gait analysis, which helps better understanding the cause of many diseases for more effective treatments, such as rehabilitation for outpatients or recovery from lost motor functions after a stroke. In order to achieve real-time ambulatory human motion tracking with low-cost MARG (magnetic, angular rate, and gravity) sensors, a computationally efficient and robust algorithm for orientation estimation is critical. This paper presents an analytically derived method for an adaptive-gain complementary filter based on the convergence rate from the Gauss-Newton optimization algorithm (GNA) and the divergence rate from the gyroscope, which is referred as adaptive-gain orientation filter (AGOF) in this paper. The AGOF has the advantages of one iteration calculation to reduce the computing load and accurate estimation of gyroscope measurement error. Moreover, for handling magnetic distortions especially in indoor environments and movements with excessive acceleration, adaptive measurement vectors and a reference vector for earth's magnetic field selection schemes are introduced to help the GNA find more accurate direction of gyroscope error. The features of this approach include the accurate estimation of the gyroscope bias to correct the instantaneous gyroscope measurements and robust estimation in conditions of fast motions and magnetic distortions. Experimental results are presented to verify the performance of the proposed method, which shows better accuracy of orientation estimation than several well-known methods.
2 April 2015 in IEEE Journal of Biomedical and Health Informatics
Food recognition is a key component in evaluation of everyday food intakes, and its challenge is due to intraclass variation. In this paper, we present an automatic food classification method, DietCam, which specifically addresses the variation of food appearances. DietCam consists of two major components, ingredient detection and food classification. Food ingredients are detected through a combination of a deformable part-based model and a texture verification model. From the detected ingredients, food categories are classified using a multiview multikernel SVM. In the experiment, DietCam presents reliability and outperformance in recognition of food with complex ingredients on a database including 15,262 food images of 55 food types.