Hyun Lee

Dr. Hyun Lee


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2017 in Materials
Verified
Journal Article
Open access
PDF file
HLHyun Lee
Hyun Lee
TJTae-Sik Jang
Tae-Sik Jang
JSJuha Song
Juha Song
HKHyoun-Ee Kim
Hyoun-Ee Kim
Hyun-Do JungHyun-Do Jung
Hyun-Do Jung
Porous hydroxyapatite (HA) scaffolds with porosity-graded structures were fabricated by sequential freeze-casting. The pore structures, compressive strengths, and biocompatibilities of the fabricated porous HA scaffolds were evaluated. The porosities of the inner and outer layers of the graded HA scaffolds were controlled by adjusting the initial HA contents of the casting slurries. The interface between the dense and porous parts was compact and tightly adherent. The porosity and compressive strengths of the scaffold were controlled by the relative thicknesses of the dense/porous parts. In addition, the porous HA scaffolds showed good biocompatibility in terms of preosteoblast cell attachment and proliferation. The results suggest that porous HA scaffolds with load-bearing parts have potential as bone grafts in hard-tissue engineering.

7 February 2018 in Materials
Verified
Journal Article
Open access
PDF file
IKIn-Gu Kang
In-Gu Kang
CPCheon-Il Park
Cheon-Il Park
HLHyun Lee
Hyun Lee
HKHyoun-Ee Kim
Hyoun-Ee Kim
SLSung-Mi Lee
Sung-Mi Lee
This study demonstrates the utility of hydroxyapatite (HA) microspheres as an additive to enhance the radiopaque properties, biocompatibility, and osteoconductivity of poly(methyl methacrylate) (PMMA)-based bone cements. HA microspheres were synthesized using spray drying. They had well-defined spherical shapes, thus allowing for the production of PMMA/HA composites with a very high HA content (20 vol % and 40 vol %). The uniform distribution of these HA microspheres in the PMMA matrix resulted in a remarkable increase in compressive modulus (p < 0.05), while preserving a reasonably high compressive strength. The PMMA/HA bone cements showed much higher radiopacity than PMMA containing BaSO4 as the additive. This was attributed to the high HA content up to 40 vol %. In addition, the biocompatibility and osteoconductivity of PMMA/HA bone cements were significantly enhanced compared to those of PMMA bone cements containing BaSO4, which were assessed using in vitro tests and in vivo animal experiments.

11 April 2021 in Metals
Verified
Journal Article
Open access
PDF file
JKJinyoung Kim
Jinyoung Kim
HLHyun Lee
Hyun Lee
TJTae-Sik Jang
Tae-Sik Jang
DKDongEung Kim
DongEung Kim
CYChang-Bun Yoon
Chang-Bun Yoon
Hyun-Do JungHyun-Do Jung
Hyun-Do Jung
As biocompatible metallic materials, titanium and its alloys have been widely used in the orthopedic field due to their superior strength, low density, and ease of processing. However, further improvement in biological response is still required for rapid osseointegration. Here, various Ti surface-treatment technologies were applied: hydroxyapatite blasting, sand blasting and acid etching, anodic oxidation, and micro-arc oxidation. The surface characteristics of specimens subjected to these techniques were analyzed in terms of structure, elemental composition, and wettability. The adhesion strength of the coating layer was also assessed for the coated specimens. Biocompatibility was compared via tests of in vitro attachment and proliferation of pre-osteoblast cells.

7 June 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
MLMin-Kyu Lee
Min-Kyu Lee
HLHyun Lee
Hyun Lee
HKHyoun-Ee Kim
Hyoun-Ee Kim
ELEun-Jung Lee
Eun-Jung Lee
TJTae-Sik Jang
Tae-Sik Jang
Hyun-Do JungHyun-Do Jung
Hyun-Do Jung
Nano-scale surface roughening of metallic bio-implants plays an important role in the clinical success of hard tissue reconstruction and replacement. In this study, the nano-topographical features of titanium-niobium-zirconium (TNZ) alloy surfaces were controlled by using the target-ion induced plasma sputtering (TIPS) technique to improve the in vitro osteoblastic response. The TIPS technique is a novel strategy for etching the surface of metallic bio-implants using bombardment of target metal cations, which were accelerated by an extremely high negative bias voltage applied to the substrates. The nano-topography of the TNZ surfaces was successfully controlled by modulating experimental variables (such as the ion etching energy and the type of substrate or target materials) of TIPS. As a result, various nanopatterns (size: 10–210 nm) were fabricated on the surface of the TNZ alloys. Compared with the control group, experimental groups with nanopattern widths of ≥130 nm (130 and 210 nm groups) exhibited superior cell adhesion, proliferation, and differentiation. Our findings demonstrate that TIPS is a promising technology that can impart excellent biological functions to the surface of metallic bio-implants.

21 August 2019 in Materials
Verified
Journal Article
Open access
PDF file
JCJae-Won Choi
Jae-Won Choi
WMWoo-Youl Maeng
Woo-Youl Maeng
Young-Hag KohYoung-Hag Koh
Young-Hag Koh
HLHyun Lee
Hyun Lee
HKHyoun-Ee Kim
Hyoun-Ee Kim
This study demonstrates the utility of camphene as the pore-regulating agent for phase separation-based 3D plotting to produce hierarchical macro/micro-porous poly(ε-caprolactone) (PCL)–calcium phosphate (CaP) composite scaffolds, specifically featuring highly microporous surfaces. Unlike conventional particulate porogens, camphene is highly soluble in acetone, the solvent for PCL polymer, but insoluble in coagulation medium (water). In this study, this unique characteristic supported the creation of numerous micropores both within and at the surfaces of PCL and PCL–CaP composite filaments when using high camphene contents (40 and 50 wt%). In addition, the incorporation of the CaP particles into PCL solutions did not deteriorate the formation of microporous structures, and thus hierarchical macro/micro-porous PCL–CaP composite scaffolds could be successfully produced. As the CaP content increased, the in vitro biocompatibility, apatite-forming ability, and mechanical properties (tensile strength, tensile modulus, and compressive modulus) of the PCL–CaP composite scaffolds were substantially improved.

22 December 2023 in Metals
Verified
Journal Article
Open access
PDF file
SOSeKwon Oh
SeKwon Oh
JAJi-Ho Ahn
Ji-Ho Ahn
RJRockhoon Jung
Rockhoon Jung
HKHyun-Jong Kim
Hyun-Jong Kim
YCYounghwan Chu
Younghwan Chu
Hyun-Do JungHyun-Do Jung
Hyun-Do Jung
Developing next-generation thermal-neutron-shielding and -absorbing materials for the safe storage and transportation of spent nuclear fuel is a topic of active research in academia. Gadolinium (Gd) boasts superior neutron absorption capacity compared with other nuclei. Consequently, it has garnered significant attention as a potential replacement for boron in spent nuclear fuel (SNF) applications. In this study, the austenitic stainless steels 304 and 316 and the duplex stainless steel 5A were reinforced with 2 wt.% of gadolinium to explore their thermal-neutron-absorbing efficiency. Their properties were then compared with commercial-grade borated stainless steel, as per ASTM standard A887. After the inclusion of Gd, both the yield strength and ultimate tensile strength of the alloys slightly increased, which was attributed to the evenly distributed Gd intermetallics within the matrix. However, the elongation rate was reduced. The Charpy impact absorption energy also decreased. The influence of the Gd intermetallic was further explored by examining the fractography. While the corrosion resistance of the alloy slightly diminished after the addition of Gd, its neutron absorption capacity demonstrated superior performance, especially when the Gd content was equivalent to that of boron. Although most properties of the experimental alloy deteriorated after the Gd addition, they still outperformed commercial borated stainless steel, suggesting that this alloy might be a promising candidate for SNF applications.