Accelerometers are a technology that is increasingly used in the evaluation of animal behaviour. A tri-axial accelerometer attached to a vest was used on Tamandua tetradactyla individuals (n = 10) at Biodiversity Park. First, the influence of using a vest on the animals’ behaviour was evaluated (ABA-type: A1 and A2, without a vest; B, with a vest; each stage lasted 24 h), and no changes were detected. Second, their behaviour was monitored using videos and the accelerometer simultaneously (experimental room, 20 min). The observed behaviours were correlated with the accelerometer data, and summary measures (X, Y and Z axes) were obtained. Additionally, the overall dynamic body acceleration was calculated, determining a threshold to discriminate activity/inactivity events (variance = 0.0055). Then, based on a 24 h complementary test (video sampling every 5 min), the sensitivity (85.91%) and precision (100%) of the accelerometer were assessed. Animals were exposed to an ABA-type experimental design: A1 and A2: complex enclosure; B: decreased complexity (each stage lasted 24 h). An increase in total activity (%) was revealed using the accelerometer (26.15 ± 1.50, 29.29 ± 2.25, and 35.36 ± 3.15, respectively). Similar activity levels were detected using video analysis. The results demonstrate that the use of the accelerometer is reliable to determine the activity. Considering that the zoo-housed lesser anteaters exhibit a cathemeral activity pattern, this study contributes to easily monitoring their activities and responses to different management procedures supporting welfare programs, as well as ex situ conservation.
23 December 2011 in Journal of Physics: Conference Series
This paper presents the use of a Real Time Operating System (RTOS) on a portable electrocardiograph based on a microcontroller platform. All medical device digital functions are performed by the microcontroller. The electrocardiograph CPU is based on the 18F4550 microcontroller, in which an uCOS-II RTOS can be embedded. The decision associated with the kernel use is based on its benefits, the license for educational use and its intrinsic time control and peripherals management. The feasibility of its use on the electrocardiograph is evaluated based on the minimum memory requirements due to the kernel structure. The kernel's own tools were used for time estimation and evaluation of resources used by each process. After this feasibility analysis, the migration from cyclic code to a structure based on separate processes or tasks able to synchronize events is used; resulting in an electrocardiograph running on one Central Processing Unit (CPU) based on RTOS.