Radoslaw Z. Gocol

Dr. Radoslaw Z. Gocol

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
HHHubert Hymczak
Hubert Hymczak
AGAleksandra Gołąb
Aleksandra Gołąb
KMKonrad Mendrala
Konrad Mendrala
DPDariusz Plicner
Dariusz Plicner
Tomasz DarochaTomasz Darocha
Tomasz Darocha
SKSylweriusz Kosiński
Sylweriusz Kosiński
Core temperature reflects the temperature of the internal organs. Proper temperature measurement is essential to diagnose and treat temperature impairment in patients. However, an accurate approach has yet to be established. Depending on the method used, the obtained values may vary and differ from the actual core temperature. There is an ongoing debate regarding the most appropriate anatomical site for core temperature measurement. Although the measurement of body core temperature through a pulmonary artery catheter is commonly cited as the gold standard, the esophageal temperature measurement appears to be a reasonable and functional alternative in the clinical setting. This article provides an integrative review of invasive and noninvasive body temperature measurements and their relations to core temperature.

RGRadoslaw Z. Gocol
Radoslaw Z. Gocol
DHDamian Hudziak
Damian Hudziak
JBJarosław Bis
Jarosław Bis
KMKonrad Mendrala
Konrad Mendrala
ŁMŁukasz Morkisz
Łukasz Morkisz
Tomasz DarochaTomasz Darocha
Tomasz Darocha
Hypothermia is defined as a decrease in body core temperature to below 35 °C. In cardiac surgery, four stages of hypothermia are distinguished: mild, moderate, deep, and profound. The organ protection offered by deep hypothermia (DH) enables safe circulatory arrest as a prerequisite to carrying out cardiac surgical intervention. In adult cardiac surgery, DH is mainly used in aortic arch surgery, surgical treatment of pulmonary embolism, and acute type-A aortic dissection interventions. In surgery treating congenital defects, DH is used to assist aortic arch reconstructions, hypoplastic left heart syndrome interventions, and for multi-stage treatment of infants with a single heart ventricle during the neonatal period. However, it should be noted that a safe duration of circulatory arrest in DH for the central nervous system is 30 to 40 min at most and should not be exceeded to prevent severe neurological adverse events. Personalized therapy for the patient and adequate blood temperature monitoring, glycemia, hematocrit, pH, and cerebral oxygenation is a prerequisite and indispensable part of DH.

6 January 2021 in BMC Cardiovascular Disorders
Verified
Journal Article
Open access
PDF file
MJMarek J. Jasinski
Marek J. Jasinski
KMKarol Miszalski-Jamka
Karol Miszalski-Jamka
KKKinga Kosiorowska
Kinga Kosiorowska
RGRadoslaw Z. Gocol
Radoslaw Z. Gocol
IWIzabella Wenzel-Jasinska
Izabella Wenzel-Jasinska
MDMarek A. Deja
Marek A. Deja
Background: The incompetent bicuspid aortic valve (BAV) can be replaced or repaired using various surgical techniques. This study sought to assess the efficacy of external annuloplasty and postoperative reverse remodelling using cardiac magnetic resonance (CMR) and compare the results of external and subcommissural annuloplasty.Methods: Out of a total of 200 BAV repair performed between 2004 and 2018, 21 consecutive patients (median age 54 years) with regurgitation requiring valve repair with annuloplasty without concomitant aortic root surgery were prospectively referred for CMR and transthoracic echocardiography (TTE) one year after the operation. Two aortic annulus stabilization techniques were used: external, circumferential annuloplasty (EA), and subcommissural annuloplasty (SCA).Results: 11 patients received EA and 10 patients were treated using SCA. There was no in-hospital mortality and all patients survived the follow-up period (median: 12.6 months (first quartile: 6.6; third quartile: 14.1). CMR showed strong correlation between postoperative aortic recurrent regurgitant fraction and left ventricular end-diastolic volume (r = 0.62; p = 0.003) as well as left ventricular ejection fraction (r = -0.53; p = 0.01). Patients treated with EA as compared with SCA had larger anatomic aortic valve area measured by CMR (3.5 (2.5; 4.0) vs. 2.5 cm2(2.0; 3.4); p = 0.04). In both EA and SCA group, aortic valve area below 3.5 cm2correlated with no regurgitation recurrency. EA (vs. SCA) was associated with lower peak transvalvular aortic gradients (10 (6; 17) vs. 21 mmHg (15; 27); p = 0.04).Conclusions: The repair of the bicuspid aortic valve provides significant postoperative reverse remodelling, provided no recurrent regurgitation and durable reduction annuloplasty can be achieved. EA is associated with lower transvalvular gradients and higher aortic valve area assessed by CMR, compared to SCA.

22 January 2020 in Cardiology Journal
Verified
Journal Article
Open access
PDF file
RGRadoslaw Z. Gocol
Radoslaw Z. Gocol
MJMarek Jasiński
Marek Jasiński
DHDamian Hudziak
Damian Hudziak
JBJarosław Bis
Jarosław Bis
AŻAleksandra Żak
Aleksandra Żak
MDMarek A. Deja
Marek A. Deja

HHHubert Hymczak
Hubert Hymczak
PPPawel Podsiadlo
Pawel Podsiadlo
SKSylweriusz Kosiński
Sylweriusz Kosiński
Mathieu PasquierMathieu Pasquier
Mathieu Pasquier
KMKonrad Mendrala
Konrad Mendrala
Tomasz DarochaTomasz Darocha
Tomasz Darocha
Background: While ECLS is a highly invasive procedure, the identification of patients with a potentially good prognosis is of high importance. The aim of this study was to analyse changes in the acid-base balance parameters and lactate kinetics during the early stages of ECLS rewarming to determine predictors of clinical outcome. Methods: This single-centre retrospective study was conducted at the Severe Hypothermia Treatment Centre at John Paul II Hospital in Krakow, Poland. Patients ≥18 years old who had a core temperature (Tc) < 30 °C and were rewarmed with ECLS between December 2013 and August 2018 were included. Acid-base balance parameters were measured at ECLS implantation, at Tc 30 °C, and at 2 and 4 h after Tc 30 °C. The alteration in blood lactate kinetics was calculated as the percent change in serum lactate concentration relative to the baseline. Results: We included 50 patients, of which 36 (72%) were in cardiac arrest. The mean age was 56 ± 15 years old, and the mean Tc was 24.5 ± 12.6 °C. Twenty-one patients (42%) died. Lactate concentrations in the survivors group were significantly lower than in the non-survivors at all time points. In the survivors group, the mean lactate concentration decreased −2.42 ± 4.49 mmol/L from time of ECLS implantation until 4 h after reaching Tc 30 °C, while in the non-survivors’ group (p = 0.024), it increased 1.44 ± 6.41 mmol/L. Conclusions: Our results indicate that high lactate concentration is associated with a poor prognosis for hypothermic patients undergoing ECLS rewarming. A decreased value of lactate kinetics at 4 h after reaching 30 °C is also associated with a poor prognosis.

1 January 2021 in Annals of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Open access
PDF file
RGRadoslaw Z. Gocol
Radoslaw Z. Gocol
JBJarosław Bis
Jarosław Bis
DHDamian Hudziak
Damian Hudziak
ŁMŁukasz Morkisz
Łukasz Morkisz
MDMarek A. Deja
Marek A. Deja
Purpose: We propose a novel technique for reconstruction of the dissected aortic root with the use of TachoSil fibrin sealant patch.Methods: Patients with acute type A aortic dissection involving the aortic root were included. Appropriately prepared TachoSil fibrin sealant patch was placed between the dissected layers of the aortic root to achieve their durable fusion. Thus, the false lumen was eliminated, and the anatomical and functional structure of the aortic wall was restored.Results: In all, 13 patients mean aged 57 ± 10.3 years underwent surgery for acute type A aortic dissection with the use of TachoSil fibrin sealant patch. All patients survived the surgery. The mean follow-up time was 30.8 ± 16.4 months. Follow-up computed tomography angiography (CTA) scans confirmed no aortic root dissection in all patients.Conclusions: This technique ensures durable restoration of the aortic wall structure, eliminates the secondary aortic valve regurgitation, and allows for the preservation of patients’ native aortic valve.