Cough generated infectious aerosols are of interest while developing strategies for the mitigation of disease risks ranging from the common cold to SARS. In this work, the velocity field of human cough was measured using particle image velocimetry (PIV). The project subjects (total 29) coughed into an enclosure seeded with stage fog. Cough flow velocity profiles, average widths of the cough jet, and maximum cough velocities were measured. Maximum cough velocities ranged from 1.5 m/s to 28.8 m/s. The average width of all coughs ranged between 35 to 45 mm. Wide variability in the data suggests that future cough simulations consider a range of conditions.
Background —Early recognition of heart disease is an important goal in pediatrics. Efforts in developing an inexpensive screening device that can assist in the differentiation between innocent and pathological heart murmurs have met with limited success. Artificial neural networks (ANNs) are valuable tools used in complex pattern recognition and classification tasks. The aim of the present study was to train an ANN to distinguish between innocent and pathological murmurs effectively. Methods and Results —Using an electronic stethoscope, heart sounds were recorded from 69 patients (37 pathological and 32 innocent murmurs). Sound samples were processed using digital signal analysis and fed into a custom ANN. With optimal settings, sensitivities and specificities of 100% were obtained on the data collected with the ANN classification system developed. For future unknowns, our results suggest the generalization would improve with better representation of all classes in the training data. Conclusion —We demonstrated that ANNs show significant potential in their use as an accurate diagnostic tool for the classification of heart sound data into innocent and pathological classes. This technology offers great promise for the development of a device for high-volume screening of children for heart disease.
Pulmonary hypertension (PH) is associated with proximal pulmonary arterial remodeling characterized by increased vessel diameter, wall thickening, and stiffness. In vivo assessment of wall shear stress (WSS) may provide insights into the relationships between pulmonary hemodynamics and vascular remodeling. We investigated the relationship between main pulmonary artery (MPA) WSS and pulmonary hemodynamics as well as markers of stiffness. As part of a prospective study, 17 PH patients and 5 controls underwent same‐day four‐dimensional flow cardiac magnetic resonance imaging (4‐D CMR) and right heart catheterization. Streamwise velocity profiles were generated in the cross‐sectional MPA in 45° increments from velocity vector fields determined by 4‐D CMR. WSS was calculated as the product of hematocrit‐dependent viscosity and shear rate generated from the spatial gradient of the velocity profiles. In‐plane average MPA WSS was significantly decreased in the PH cohort compared with that in controls (0.18 ± 0.07 vs. 0.32 ± 0.08 N/m2; P = 0.01). In‐plane MPA WSS showed strong inverse correlations with multiple hemodynamic indices, including pulmonary resistance (ρ = –0.74, P < 0.001), mean pulmonary pressure (ρ = –0.64, P = 0.006), and elastance (ρ = –0.70, P < 0.001). In addition, MPA WSS had significant associations with markers of stiffness, including capacitance (ρ = 0.67, P < 0.001), distensibility (ρ = 0.52, P = 0.013), and elastic modulus (ρ = –0.54, P = 0.01). In conclusion, MPA WSS is decreased in PH and is significantly associated with invasive hemodynamic indices and markers of stiffness. 4‐D CMR‐based assessment of WSS may represent a novel methodology to study blood‐vessel wall interactions in PH.
This letter reports on a contrast-based ultrasonic particle imaging technique (echo PIV) for measuring multicomponent velocity vectors in opaque flows with excellent temporal (up to ) and spatial (up to ) resolution. Ultrasound contrast microbubbles are used as flow tracers, and digitally acquired rf data are converted into -mode images for PIV analysis. Here, velocity fields from various flow patterns (including rotating and transient vortex flows) that are difficult to measure using other opaque flow methods such as ultrasound Doppler or magnetic resonance imaging are measured using echo PIV. This nonintrusive technique should be a promising addition to opaque flow diagnostics.