Samineni Peddakrishna

Dr. Samineni Peddakrishna

VIT-AP University, Bezwāda, Andhra Pradesh, International
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2023 in Processes
Verified
Journal Article
Open access
PDF file
NCNADIKATLA CHANDRASEKHAR
NADIKATLA CHANDRASEKHAR
SPSamineni Peddakrishna
Samineni Peddakrishna
In the medical domain, early identification of cardiovascular issues poses a significant challenge. This study enhances heart disease prediction accuracy using machine learning techniques. Six algorithms (random forest, K-nearest neighbor, logistic regression, Naïve Bayes, gradient boosting, and AdaBoost classifier) are utilized, with datasets from the Cleveland and IEEE Dataport. Optimizing model accuracy, GridsearchCV, and five-fold cross-validation are employed. In the Cleveland dataset, logistic regression surpassed others with 90.16% accuracy, while AdaBoost excelled in the IEEE Dataport dataset, achieving 90% accuracy. A soft voting ensemble classifier combining all six algorithms further enhanced accuracy, resulting in a 93.44% accuracy for the Cleveland dataset and 95% for the IEEE Dataport dataset. This surpassed the performance of the logistic regression and AdaBoost classifiers on both datasets. This study’s novelty lies in the use of GridSearchCV with five-fold cross-validation for hyperparameter optimization, determining the best parameters for the model, and assessing performance using accuracy and negative log loss metrics. This study also examined accuracy loss for each fold to evaluate the model’s performance on both benchmark datasets. The soft voting ensemble classifier approach improved accuracies on both datasets and, when compared to existing heart disease prediction studies, this method notably exceeded their results.

30 April 2024 in Biomedical Signal Processing and Control
Verified
Journal Article
Closed access
SKSreedhar Kollem
Sreedhar Kollem
CSChandrasekhar Sirigiri
Chandrasekhar Sirigiri
SPSamineni Peddakrishna
Samineni Peddakrishna

28 March 2024 in Heliyon
Verified
Journal Article
Open access
M NareshM Naresh
M Naresh
VNV. Siva Nagaraju
V. Siva Nagaraju
SKSreedhar Kollem
Sreedhar Kollem
JKJayendra Kumar
Jayendra Kumar
SPSamineni Peddakrishna
Samineni Peddakrishna
In this paper, a dual wavelength short near-infrared system is described for the detection of glucose levels. The system aims to improve the accuracy of blood glucose detection in a cost-effective and non-invasive way. The accuracy of the method is evaluated using real-time samples collected with the reference finger prick glucose device. A feed forward neural network (FFNN) regression method is employed to predict glucose levels based on the input data obtained from NIR technology. The system calculates glucose evaluation metrics and performs Surveillance error grid (SEG) analysis. The coefficient of determination R2 and mean absolute error are observed 0.99 and 2.49 mg/dl, respectively. Additionally, the system determines the root mean square error (RMSE) as 3.02 mg/dl. It also shows that the mean absolute percentage error (MAPE) is 1.94% and mean squared error (MSE) is 9.16 (mg/dl)2 for FFNN. The SEG analysis shows that the glucose values measured by the system fall within the clinically acceptable range when compared to the reference method. Finally, the system uses the multi-class classification method of the multilayer perceptron (MLP) and K-nearest neighbors (KNN) classifier to classify glucose levels with an accuracy of 99%.

19 October 2022 in Sensors
Verified
Journal Article
Open access
PDF file
VKVamshi Kollipara
Vamshi Kollipara
SPSamineni Peddakrishna
Samineni Peddakrishna
This article studies a quad-port multi-input-multi-output (MIMO) circularly polarized antenna with good isolation properties. Using characteristic mode analysis (CMA), the first six distinct modes of the asymmetric square slot with an inverted L-strip are analyzed. In this study, modal parameter extraction is carried out for circular polarization (CP) radiation. A simple annular ring microstrip feed is excited to obtain broadband CP based on CMA. The single-unit feeding structure is replicated orthogonally four times to achieve a CP MIMO antenna. This antenna provides port isolation of more than 21 dB without the use of an additional decoupling element. The quad-port CP-MIMO antenna is simulated with a total dimension of 50 × 50 mm2. The antenna attains impedance matching (S11 < −10 dB) from 5.37 GHz to beyond 11 GHz with an axial ratio bandwidth (ARBW) of 4.65 GHz (5.61 GHz to 10.26 GHz). The peak realized gain of the MIMO antenna is measured at 5.69 dBi at 8.4 GHz. Additionally, the diversity performance parameters of the MIMO structure are computed. The advantages of the proposed structure have been evaluated by comparing it to previously reported MIMO structures. A prototype of the MIMO structure measurements was found to match the simulation results.

10 January 2025 in Results in Engineering
Verified
Journal Article
Open access
ZSZuber Basha Shaik
Zuber Basha Shaik
SPSamineni Peddakrishna
Samineni Peddakrishna

18 January 2025 in Results in Engineering
Verified
Journal Article
Open access
NCNadikatla Chandrasekhar
Nadikatla Chandrasekhar
SNSujatha Canavoy Narahari
Sujatha Canavoy Narahari
SKSreedhar Kollem
Sreedhar Kollem
SPSamineni Peddakrishna
Samineni Peddakrishna
APArchana Penchala
Archana Penchala
BCBabji Prasad Chapa
Babji Prasad Chapa