Michiko Nishiyama

Dr. Michiko Nishiyama


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2011 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
MNMichiko Nishiyama
Michiko Nishiyama
MMMitsuo Miyamoto
Mitsuo Miyamoto
KWKazuhiro Watanabe
Kazuhiro Watanabe
We describe respiration monitoring in sleep using hetero-core fiber optic pressure sensors. The proposed hetero-core fiber optic sensor is highly sensitive to macrobending as a result of the core diameter difference due to stable single-mode transmission. Pressure sensors based on hetero-core fiber optics were fabricated to have a high sensitivity to small pressure changes resulting from minute body motions, such as respiration, during sleep and large pressure changes, such as those caused by a rollover. The sensors are installed in a conventional bed. The pressure characteristic performance of all the fabricated hetero-core fiber optic pressure sensors is found to show a monotonic response with weight changes. A respiration monitoring test in seven subjects efficiently demonstrates the effective use of eight hetero-core pressure sensors installed in a bed. Additionally, even in the case of different body postures, such as lying on one's side, a slight body movement due to respiration is detected by the hetero-core pressure sensors.

26 August 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
MNMichiko Nishiyama
Michiko Nishiyama
MSMasako Sonobe
Masako Sonobe
KWKazuhiro Watanabe
Kazuhiro Watanabe
In this paper, we present a pulse pressure waveform sensor that does not constrain a wearer’s daily activity; the sensor uses hetero-core fiber optics. Hetero-core fiber sensors have been found to be sensitive to moderate bending. To detect minute pulse pressure changes from the radial artery at the wrist, we devised a fiber sensor arrangement using three-point bending supports. We analyzed and evaluated the measurement validity using wavelet transformation, which is well-suited for biological signal processing. It was confirmed that the detected pulse waveform had a fundamental mode frequency of around 1.25 Hz over the time-varying waveform. A band-pass filter with a range of frequencies from 0.85 to 1.7 Hz was used to pick up the fundamental mode. In addition, a high-pass filter with 0.85 Hz frequency eliminated arm motion artifacts; consequently, we achieved high signal-to-noise ratio. For unrestricted daily health management, it is desirable that pulse pressure monitoring can be achieved by simply placing a device on the hand without the sensor being noticed. Two types of arrangements were developed and demonstrated in which the pulse sensors were either embedded in a base, such as an armrest, or in a wearable device. A wearable device without cuff pressure using a sensitivity-enhanced fiber sensor was successfully achieved with a sensitivity of 0.07–0.3 dB with a noise floor lower than 0.01 dB for multiple subjects.

21 December 2020 in Optics Express
Verified
Journal Article
Closed access
MMMasahiro Mikami
Masahiro Mikami
DKDaisuke Komatsu
Daisuke Komatsu
AHAi Hosoki
Ai Hosoki
MNMichiko Nishiyama
Michiko Nishiyama
HIHirotaka Igawa
Hirotaka Igawa
KWKazuhiro Watanabe
Kazuhiro Watanabe
A novel fiber optic localized surface plasmon resonance (LSPR) hydrogen sensor has been developed based on the hetero-core structured with palladium nanoparticles (PdNPs) onto a cylindrical cladding surface. In a light-intensity-based experiment with an LED operating at 850 nm, it has been observed that a transmitted loss change of 0.23 dB was induced with response and recovery times of 1.5 and 3.2 s for 4% hydrogen which are the fastest response times among optical fiber hydrogen sensors. The proposed sensor resolved the inevitable trade-off issue between sensitivity and response time which existed in the previously reported SPR sensors, with keeping the response time below 2.0 s even in a high sensitivity region of interest.

2 August 2018 in Sensors
Verified
Journal Article
Open access
PDF file
HYHiroshi Yamazaki
Hiroshi Yamazaki
IKIchiro Kurose
Ichiro Kurose
MNMichiko Nishiyama
Michiko Nishiyama
KWKazuhiro Watanabe
Kazuhiro Watanabe
In this paper, a novel pendulum-type accelerometer based on hetero-core fiber optics has been proposed for structural health monitoring targeting large-scale civil infrastructures. Vibration measurement is a non-destructive method for diagnosing the failure of structures by assessing natural frequencies and other vibration patterns. The hetero-core fiber optic sensor utilized in the proposed accelerometer can serve as a displacement sensor with robustness to temperature changes, in addition to immunity to electromagnetic interference and chemical corrosions. Thus, the hetero-core sensor inside the accelerometer measures applied acceleration by detecting the rotation of an internal pendulum. A series of experiments showed that the hetero-core fiber sensor linearly responded to the rotation angle of the pendulum ranging within (−6°, 4°), and furthermore the proposed accelerometer could reproduce the waveform of input vibration in a frequency band of several Hz order.

13 September 2022 in Optics Express
Verified
Journal Article
Open access
AHAi Hosoki
Ai Hosoki
MNMichiko Nishiyama
Michiko Nishiyama
KWKazuhiro Watanabe
Kazuhiro Watanabe
NSNozomu Sakurai
Nozomu Sakurai
This study experimentally demonstrated the effects of two polarization-maintaining fibers (PMFs) as a sensing region instead of conventional single-mode fiber (SMF) using Au-coated hetero-core optical fiber surface plasmon resonance (SPR) sensor. We experimentally observed that the SPR resonant wavelength is shifted toward longer wavelength with refractive index (RI) increasing from 1.332 to 1.396. A PMF sensor exhibits the broad SPR spectra, resulting in a higher sensitivity with a 1.5-fold change in the light intensity at 850 nm relative to RI, compared with the SMF case. Discussions most likely responsible for this effect are given by the lower angular distribution peak in the hetero-core region of PMFs.

20 February 2023 in Sensors
Verified
Journal Article
Open access
PDF file
MMMasanori Maeda
Masanori Maeda
MKMiyuki Kadokura
Miyuki Kadokura
RARyoko Aoki
Ryoko Aoki
NKNoriko Komatsu
Noriko Komatsu
MKMasaru Kawakami
Masaru Kawakami
MNMichiko Nishiyama
Michiko Nishiyama
We developed a wearable swallowing assessment device using a hetero-core fiber-optic pressure sensor for the detection of laryngeal movement during swallowing. The proposed pressure sensor (comfortably attached to the skin of the neck) demonstrated a high sensitivity of 0.592 dB/kPa and a linearity of R2 = 0.995 within a 14 kPa pressure band, which is a suitable pressure for the detection of laryngeal movement. In addition, since the fabricated hetero-core fiber-optic pressure sensor maintains appreciable sensitivity over the surface of the sensor, the proposed wearable swallowing assessment device can accurately track the subtle pressure changes induced by laryngeal movements during the swallowing process. Sixteen male subjects and one female subject were evaluated in a variety of age groups ranging from 30 to 60 years old. For all subjects, characteristic swallowing waveforms (with two valleys based on laryngeal movements consisting of upward, forward, backward, and downward displacements) were acquired using the proposed wearable swallowing assessment device. Since the denoted time of the first valley in the acquired waveform determines the “aging effect”, significant differences in swallowing functions among the different age groups were ultimately determined based on the time of the first valley. Additionally, by analyzing each age group using the proposed device, due to p-values being consistently less than 0.05, swallowing times were found to exhibit statistically significant differences within the same groups.