Enrique Mario Spinelli

Dr. Enrique Mario Spinelli


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2003 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
ESEnrique Mario Spinelli
Enrique Mario Spinelli
RPR. Pallas-Areny
R. Pallas-Areny
MMM.A. Mayosky
M.A. Mayosky
AC coupling is essential in biopotential measurements. Electrode offset potentials can be several orders of magnitude larger than the amplitudes of the biological signals of interest, thus limiting the admissible gain of a dc-coupled front end to prevent amplifier saturation. A high-gain input stage needs ac input coupling. This can be achieved by series capacitors, but in order to provide a bias path, grounded resistors are usually included, which degrade the common mode rejection ratio (CMRR). This paper proposes a novel balanced input ac-coupling network that provides a bias path without any connection to ground, thus resulting in a high CMRR. The circuit being passive, it does not limit the differential dc input voltage. Furthermore, differential signals are ac coupled, whereas common-mode voltages are dc coupled, thus allowing the closed-loop control of the dc common mode voltage by means of a driven-right-leg circuit. This makes the circuit compatible with common-mode dc shifting strategies intended for single-supply biopotential amplifiers. The proposed circuit allows the implementation of high-gain biopotential amplifiers with a reduced number of parts, thus resulting in low power consumption. An electrocardiogram amplifier built according to the proposed design achieves a CMRR of 123 dB at 50 Hz.

10 September 2010 in Physiological Measurement
Verified
Journal Article
Closed access
ESEnrique Mario Spinelli
Enrique Mario Spinelli
MHMarcelo Haberman
Marcelo Haberman
Insulating electrodes, also known as capacitive electrodes, allow acquiring biopotentials without galvanic contact with the body. They operate with displacement currents instead of real charge currents, and the electrolytic electrode-skin interface is replaced by a dielectric film. The use of insulating electrodes is not the end of electrode interface problems but the beginning of new ones: coupling capacitances are of the order of pF calling for ultra-high input impedance amplifiers and careful biasing, guarding and shielding techniques. In this work, the general requirements of front ends for capacitive electrodes are presented and the different contributions to the overall noise are discussed and estimated. This analysis yields that noise bounds depend on features of the available devices as current and voltage noise, but the final noise level also depends on parasitic capacitances, requiring a careful shield and printed circuit design. When the dielectric layer is placed on the skin, the present-day amplifiers allow achieving noise levels similar to those provided by wet electrodes. Furthermore, capacitive electrode technology allows acquiring high quality ECG signals through thin clothes. A prototype front end for capacitive electrodes was built and tested. ECG signals were acquired with these electrodes in direct contact with the skin and also through cotton clothes 350 µm thick. They were compared with simultaneously acquired signals by means of wet electrodes and no significant differences were observed between both output signals.

20 July 2012 in Physiological Measurement
Verified
Journal Article
Closed access
ESEnrique Mario Spinelli
Enrique Mario Spinelli
MHMarcelo Haberman
Marcelo Haberman
PGPablo García
Pablo García
FGFederico Guerrero
Federico Guerrero
Capacitive electrodes (CEs) allow for acquiring biopotentials without galvanic contact, avoiding skin preparation and the use of electrolytic gel. The signal quality provided by present CEs is similar to that of standard wet electrodes, but they are more sensitive to electrostatic charge interference and motion artifacts, mainly when biopotentials are picked up through clothing and coupling capacitances are reduced to tens of picofarads. When artifacts are large enough to saturate the preamplifier, several seconds (up to tens) are needed to recover a proper baseline level, and during this period biopotential signals are irremediably lost. To reduce this problem, a CE that includes a fast-recovery (FR) circuit is proposed. It works directly on the coupling capacitor, recovering the amplifier from saturation while preserving ultra-high input impedance, as a CE requires. A prototype was built and tested acquiring ECG signals. Several experimental data are presented, which show that the proposed circuit significantly reduces record segment losses due to amplifier saturation when working in real environments.

19 October 2018 in Nanoscale
Verified
Journal Article
Closed access
PDF file
DCDiego Coral
Diego Coral
PSP. A. Soto
P. A. Soto
VBV. Blank
V. Blank
AVA. Veiga
A. Veiga
ESEnrique Mario Spinelli
Enrique Mario Spinelli
MRM. B. Fernández van Raap
M. B. Fernández van Raap
Magnetic hyperthermia is an oncological therapy where magnetic nanostructures, under a radiofrequency field, act as heat transducers increasing tumour temperature and killing cancerous cells. Nanostructure heating efficiency depends both on the field conditions and on the nanostructure properties and mobility inside the tumour. Such nanostructures are often incorrectly bench-marketed in the colloidal state and using field settings far off from the recommended therapeutic values. Here, we prepared nanoclusters composed of iron oxide magnetite nanoparticles crystallographically aligned and their specific absorption rate (SAR) values were calorimetrically determined in physiological fluids, agarose-gel-phantoms and ex vivo tumours extracted from mice challenged with B16-F0 melanoma cells. A portable, multipurpose applicator using medical field settings; 100 kHz and 9.3 kA m−1, was developed and the results were fully analysed in terms of nanoclusters’ structural and magnetic properties. A careful evaluation of the nanoclusters’ heating capacity in the three milieus clearly indicates that the SAR values of fluid suspensions or agarose-gel-phantoms are not adequate to predict the real tissue temperature increase or the dosage needed to heat a tumour. Our results show that besides nanostructure mobility, perfusion and local thermoregulation, the nanostructure distribution inside the tumour plays a key role in effective heating. A suppression of the magnetic material effective heating efficiency appears in tumour tissue. In fact, dosage had to be increased considerably, from the SAR values predicted from fluid or agarose, to achieve the desired temperature increase. These results represent an important contribution towards the design of more efficient nanostructures and towards the clinical translation of hyperthermia.

20 July 2011 in Medical & Biological Engineering & Computing
Verified
Journal Article
Closed access
PDF file
MHMarcelo Haberman
Marcelo Haberman
ACAugusto Cassino
Augusto Cassino
ESEnrique Mario Spinelli
Enrique Mario Spinelli

1 March 2016 in Medical Engineering & Physics
Verified
Journal Article
Closed access
ESEnrique Mario Spinelli
Enrique Mario Spinelli
FGFederico Guerrero
Federico Guerrero
PGPablo García
Pablo García
MHMarcelo Haberman
Marcelo Haberman
Capacitive Electrodes (CE) allow the acquisition of biopotentials through a dielectric layer, without the use of electrolytes, just by placing them on skin or clothing, but demands front-ends with ultra-high input impedances. This must be achieved while providing a path for bias currents, calling for ultra-high value resistors and special components and construction techniques. A simple CE that uses bootstrap techniques to avoid ultra-high value components and special materials is proposed. When electrodes are placed on the skin; that is, with coupling capacitances C(S) of around 100 pF, they present a noise level of 3.3 µV(RMS) in a 0.5-100 Hz bandwidth, which is appropriate for electrocardiography (ECG) measurements. Construction details of the CE and the complete circuit, including a fast recovery feature, are presented.