Kundan Sivashanmugan

Dr. Kundan Sivashanmugan

1. Nano Life Science Institute, Kanazawa University, Kanazawa, Japan
+1
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2018 in Nanomaterials
Verified
Journal Article
Open access
PDF file
HLHan Lee
Han Lee
Jiunn-Der LiaoJiunn-Der Liao
Jiunn-Der Liao
KSKundan Sivashanmugan
Kundan Sivashanmugan
Bernard LiuBernard Liu
Bernard Liu
WFWei-En Fu
Wei-En Fu
YJYung-Der Juang
Yung-Der Juang
Trace detection of common pesticide residue is necessary to assure safety of fruit and vegetables, given that the potential health risk to consumers is attributed to the contamination of the sources. A simple, rapid and effective means of finding the residue is however required for household purposes. In recent years, the technique in association with surface-enhanced Raman scattering (SERS) has been well developed in particular for trace detection of target molecules. Herein, gold nanoparticles (Au NPs) were integrated with sol-gel spin-coated Zirconia nanofibers (ZrO2 NFs) as a chemically stable substrate and used for SERS application. The morphologies of Au NPs/ZrO2 NFs were adjusted by the precursor concentrations (_X, X = 0.05–0.5 M) and the effect of SERS on Au NPs/ZrO2 NFs_X was evaluated by different Raman laser wavelengths using rhodamine 6G as the probe molecule at low concentrations. The target pesticides, phosmet (P1), carbaryl (C1), permethrin (P2) and cypermethrin (C2) were thereafter tested and analyzed. Au NPs/ZrO2 NFs_0.3 exhibited an enhancement factor of 2.1 × 107, which could detect P1, C1, P2 and C2 at the concentrations down to 10−8, 10−7, 10−7 and 10−6 M, respectively. High selectivity to the organophosphates was also found. As the pesticides were dip-coated on an apple and then measured on the diluted juice containing sliced apple peels, the characteristic peaks of each pesticide could be clearly identified. It is thus promising to use NPs/ZrO2 NFs_0.3 as a novel SERS-active substrate for trace detection of pesticide residue upon, for example, fruits or vegetables.

4 March 2018 in Materials
Verified
Journal Article
Open access
PDF file
CWChung-Kai Wu
Chung-Kai Wu
KSKundan Sivashanmugan
Kundan Sivashanmugan
TGTzung-Fang Guo
Tzung-Fang Guo
WCWen Ten Chin
Wen Ten Chin
In this study, the performance and stability of inverted bulk heterojunction (BHJ) polymer solar cells (PSCs) is enhanced by doping zinc oxide (ZnO) with 0–6 wt % cetyltrimethylammonium bromide (CTAB) in the sol-gel ZnO precursor solution. The power conversion efficiency (PCE) of the optimized 3 wt % CTAB-doped ZnO PSCs was increased by 9.07%, compared to a PCE of 7.31% for the pristine ZnO device. The 0–6 wt % CTAB-doped ZnO surface roughness was reduced from 2.6 to 1 nm and the number of surface defects decreased. The X-ray photoelectron spectroscopy binding energies of Zn 2p3/2 (1021.92 eV) and 2p1/2 (1044.99 eV) shifted to 1022.83 and 1045.88 eV, respectively, which is related to strong chemical bonding via bromide ions (Br−) that occupy oxygen vacancies in the ZnO lattice, improving the PCE of PSCs. The concentration of CTAB in ZnO significantly affected the work function of PSC devices; however, excessive CTAB increased the work function of the ZnO layer, resulting from the aggregation of CTAB molecules. In addition, after a 120-hour stability test in the atmosphere with 40% relative humidity, the inverted device based on CTAB-doped ZnO retained 92% of its original PCE and that based on pristine ZnO retained 68% of its original PCE. The obtained results demonstrate that the addition of CTAB into ZnO can dramatically influence the optical, electrical, and morphological properties of ZnO, enhancing the performance and stability of BHJ PSCs.

17 August 2023 in Chemosensors
Verified
Journal Article
Open access
PDF file
JLJoseph R Lakowicz
Joseph R Lakowicz
RBRamachandram Badugu
Ramachandram Badugu
KSKundan Sivashanmugan
Kundan Sivashanmugan
ARAlbert Reece
Albert Reece
In this paper, a method is described to perform ion concentration measurements on both sides of an inserted contact lens, without physical contact with the eye or the contact lens. The outer surface of an eye is covered with a tear film that has multiple layers. The central aqueous layer contains electrolytes and proteins. When a contact lens is inserted, it becomes localized in the central layer, which creates two layers known as the pre-lens tear film (PLTF) and the post-lens tear film (PoLTF). The PoLTF is in direct contact with the sensitive corneal epithelial cells which control electrolyte concentrations in tears. It is difficult to measure the overall electrolyte concentration in tears because of the small 7 μL volume of bulk tears. No methods are known, and no method has been proposed, to selectively measure the concentrations of electrolytes in the smaller volumes of the PLTF and the PoLTF. In this paper, we demonstrate the ability to localize fluorophores on each side of a contact lens without probe mixing or diffusion across the lens. We measured the concentration of sodium in the region of the PoLTF using a sodium-sensitive fluorophore positioned on the inner surface of a contact lens. The fluorescence measurements do not require physical contact and are mostly independent of eye motion and fluorophore concentration. The method is generic and can be combined with ion-sensitive fluorophores for the other electrolytes in tears. Instrumentation for non-contact measurements is likely to be inexpensive with modern opto-electronic devices. We expect these lenses to be used for measurements of other ions in the PLTF and the PoLTF, and thus become useful for both research and in the diagnosis of infections, keratitis and biomarkers for diseases.

30 June 2017 in Materials
Verified
Journal Article
Open access
PDF file
HLHan Lee
Han Lee
Jiunn-Der LiaoJiunn-Der Liao
Jiunn-Der Liao
KSKundan Sivashanmugan
Kundan Sivashanmugan
Bernard LiuBernard Liu
Bernard Liu
YSYu-Han Su
Yu-Han Su
YJYung-Der Juang
Yung-Der Juang
Porous titanium (P_Ti) is considered as an effective material for bone scaffold to achieve a stiffness reduction. Herein, biomimetic (bio-)scaffolds were made of sintered P_Ti, which used NaCl as the space holder and had it removed via the hydrothermal method. X-ray diffraction results showed that the subsequent sintering temperature of 1000 °C was the optimized temperature for preparing P_Ti. The compressive strength of P_Ti was measured using a compression test, which revealed an excellent load-bearing ability of above 70 MPa for that with an addition of 50 wt % NaCl (P_Ti_50). The nano-hardness of P_Ti, tested upon their solid surface, was presumably consistent with the density of pores vis-à-vis the addition of NaCl. Overall, a load-bearable P_Ti with a highly porous structure (e.g., P_Ti_50 with a porosity of 43.91% and a pore size around 340 μm) and considerable compressive strength could be obtained through the current process. Cell proliferation (MTS) and lactate dehydrogenase (LDH) assays showed that all P_Ti samples exhibited high cell affinity and low cell mortality, indicating good biocompatibility. Among them, P_Ti_50 showed relatively good in-cell morphology and viability, and is thus promising as a load-bearable bio-scaffold.

23 July 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
JTJiahui Tian
Jiahui Tian
XJXianhe Jiao
Xianhe Jiao
JGJiaqi Guo
Jiaqi Guo
QYQian Yu
Qian Yu
SZShuqin Zhang
Shuqin Zhang
XKXianming Kong
Xianming Kong
The presence of polycyclic aromatic hydrocarbons (PAHs) in edible oil has a serious effect on human health and may potentially induce cancer. This study combined thin-layer chromatography and surface-enhanced Raman spectroscopy (TLC-SERS) to rapidly and quantitatively detect PAHs in culinary oil. Machine learning using the principle component analysis-back propagation neural network (PCA-BP) was integrated with TLC-SERS for the detection of PAHs. Ag nanoparticles on diatomite (diatomite/Ag) TLC-SERS substrate were prepared via an in situ growth process and employed as a stationary phase in the TLC channel. The analyte sample was dropped onto the TLC channel for separation and detection. The diatomite/Ag TLC channel demonstrated excellent separation capability and superior SERS performance and successfully detected PAHs from edible oil at a sensitivity of 0.1 ppm. The PCA-BP quantitative analysis model demonstrated outstanding prediction performance. This work demonstrates that the combination of TLC-SERS technology with PCA-BP is an efficient and accurate method for quantitatively detecting PAHs in edible oil, which can effectively improve the quality of food.

20 May 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
KSKundan Sivashanmugan
Kundan Sivashanmugan
ERE. Albert Reece
E. Albert Reece
JLJoseph R Lakowicz
Joseph R Lakowicz
Blood samples and testing are routine in healthcare. Presently, there is a growing interest in using tear samples in place of blood. Tear samples can be obtained non-invasively and collection does not require the skills of a trained phlebotomist. Red blood cells and other cells are not present in tears, which avoids centrifugation. Importantly, basal tear samples contain most of the biomarkers present in blood. The difficulty is the small volume of basal tears, which is about 7 μL in each eye. Any contact with the eye results in additional reflex tears with a different chemical composition. The small tear samples are collected with capillary tubes and then sent out for amplified assays, such as enzyme-linked immunosorbent assay (ELISA) or polymerase chain reaction (PCR). The results are not available for several days or a week and, therefore, are less useful in an ophthalmology office. We propose the use of a contact lens that contains bound antibodies for fluorescence immunoassays. The lenses could be removed from the patient for point-of-care measurements at the bedside. To prove that this concept is possible, we performed a three-layer protein capture assay that mimics an immunoassay. For convenience, we used lysozyme (Lys), which spontaneously coats silicon hydrogel (SiHG) contact lenses (CL). Anti-lysozyme IgG was the second layer captured, with anti-lysozyme considered to be the target biomarker. The third layer was rhodamine or Alexa Fluor-labeled Ab against the IgG Fc region, considered to be the detection antibody. The multiple protein layers were stable and did not wash off the SiHG lenses. These results strongly suggest the contact lens can be used for capture immunoassays for a wide variety of biomarkers.