Kenichi Sakakura

Prof. Dr. Kenichi Sakakura

Division of Cardiovascular Medicine, Saitama Medical Center, Jichi Medical University, 1-847 Amanuma, Omiya, Saitama City 330-8503, Japan
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2014 in Arteriosclerosis, Thrombosis, and Vascular Biology
Verified
Journal Article
Closed access
PDF file
FOFumiyuki Otsuka
Fumiyuki Otsuka
Kenichi SakakuraKenichi Sakakura
Kenichi Sakakura
KYKazuyuki Yahagi
Kazuyuki Yahagi
MJMichael Joner
Michael Joner
RVRenu Virmani
Renu Virmani
Coronary artery calcification is a well-established predictor of future cardiac events; however, it is not a predictor of unstable plaque. The intimal calcification of the atherosclerotic plaques may begin with smooth muscle cell apoptosis and release of matrix vesicles and is almost always seen microscopically in pathological intimal thickening, which appears as microcalcification (≥0.5 μm, typically 2, <5 mm) calcification. The calcification in thin-cap fibroatheromas and plaque rupture is generally less than what is observed in stable plaques and is usually speckled or fragmented. Fragmented calcification spreads into the surrounding collagen-rich matrix forming calcified sheets, the hallmarks of fibrocalcific plaques. The calcified sheets may break into nodules with fibrin deposition, and when accompanied by luminal protrusion, it is associated with thrombosis. Calcification is highest in fibrocalcific plaques followed by healed plaque rupture and is the least in erosion and pathological intimal thickening. The extent of calcification is greater in men than in women especially in the premenopausal period and is also greater in whites compared with blacks. The mechanisms of intimal calcification remain poorly understood in humans. Calcification often occurs in the presence of apoptosis of smooth muscle cells and macrophages with matrix vesicles accompanied by expression of osteogenic markers within the vessel wall.

14 January 2014 in Circulation
Verified
Journal Article
Closed access
PDF file
FOFumiyuki Otsuka
Fumiyuki Otsuka
MVMarc Vorpahl
Marc Vorpahl
MNMasataka Nakano
Masataka Nakano
JFJason Foerst
Jason Foerst
JNJohn B. Newell
John B. Newell
RVRenu Virmani
Renu Virmani
Background—: Clinical trials have demonstrated that the second-generation cobalt-chromium everolimus-eluting stent (CoCr-EES) is superior to the first-generation paclitaxel-eluting stent (PES) and is noninferior or superior to the sirolimus-eluting stent (SES) in terms of safety and efficacy. It remains unclear whether vascular responses to CoCr-EES are different from those to SES and PES because the pathology of CoCr-EES has not been described in humans. Methods and Results—: A total of 204 lesions (SES=73; PES=85; CoCr-EES=46) from 149 autopsy cases with duration of implantation >30 days and ≤3 years were pathologically analyzed, and comparison of vascular responses was corrected for duration of implantation. The observed frequency of late and very late stent thrombosis was less in CoCr-EES (4%) versus SES (21%; P =0.029) and PES (26%; P =0.008). Neointimal thickness was comparable among the groups, whereas the percentage of uncovered struts was strikingly lower in CoCr-EES (median=2.6%) versus SES (18.0%; P <0.0005) and PES (18.7%; P <0.0005). CoCr-EES showed a lower inflammation score (with no hypersensitivity) and less fibrin deposition versus SES and PES. The observed frequency of neoatherosclerosis, however, did not differ significantly among the groups (CoCr-EES=29%; SES=35%; PES=19%). CoCr-EES had the least frequency of stent fracture (CoCr-EES=13%; SES=40%; PES=19%; P =0.007 for CoCr-EES versus SES), whereas fracture-related restenosis or thrombosis was comparable among the groups (CoCr-EES=6.5%; SES=5.5%; PES=1.2%). Conclusions—: CoCr-EES demonstrated greater strut coverage with less inflammation, less fibrin deposition, and less late and very late stent thrombosis compared with SES and PES in human autopsy analysis. Nevertheless, the observed frequencies of neoatherosclerosis and fracture-related adverse pathological events were comparable in these devices, indicating that careful long-term follow-up remains important even after CoCr-EES placement.

1 June 2013 in Heart, Lung and Circulation
Verified
Journal Article
Closed access
Kenichi SakakuraKenichi Sakakura
Kenichi Sakakura
MNMasataka Nakano
Masataka Nakano
FOFumiyuki Otsuka
Fumiyuki Otsuka
ELElena Ladich
Elena Ladich
FKFrank D. Kolodgie
Frank D. Kolodgie
RVRenu Virmani
Renu Virmani

1 August 2014 in JACC
Verified
Journal Article
Closed access
Kenichi SakakuraKenichi Sakakura
Kenichi Sakakura
ELElena Ladich
Elena Ladich
QCQi Cheng
Qi Cheng
FOFumiyuki Otsuka
Fumiyuki Otsuka
KYKazuyuki Yahagi
Kazuyuki Yahagi
MJMichael Joner
Michael Joner

1 June 2014 in Circulation: Cardiovascular Interventions
Verified
Journal Article
Closed access
FOFumiyuki Otsuka
Fumiyuki Otsuka
EPErica Pacheco
Erica Pacheco
LPLaura E.L. Perkins
Laura E.L. Perkins
JLJennifer P. Lane
Jennifer P. Lane
QWQing Wang
Qing Wang
RVRenu Virmani
Renu Virmani
Background—: The Absorb everolimus-eluting bioresorbable vascular scaffold (Absorb) has shown promising clinical results; however, only limited preclinical data have been published. We sought to investigate detailed pathological responses to the Absorb versus XIENCE V (XV) in a porcine coronary model with duration of implant extending from 1 to 42 months. Methods and Results—: A total of 335 devices (263 Absorb and 72 XV) were implanted in 2 or 3 main coronary arteries of 136 nonatherosclerotic swine and examined by light microscopy, scanning electron microscopy, pharmacokinetics, and gel permeation chromatography analyses at various time points. Vascular responses to Absorb and XV were largely comparable at all time points, with struts being sequestered within the neointima. Inflammation was mild to moderate (with absence of inflammation at 1 month) for both devices, although the scores were greater in Absorb at 6 to 36 months. Percent area stenosis was significantly greater in Absorb than XV at all time points except at 3 months. The extent of fibrin deposition was similar between Absorb and XV, which peaked at 1 month and decreased rapidly thereafter. Histomorphometry showed expansile remodeling of Absorb-implanted arteries starting after 12 months, and lumen area was significantly greater in Absorb than XV at 36 and 42 months. These changes correlated with dismantling of Absorb seen after 12 months. Gel permeation chromatography analysis confirmed that degradation of Absorb was complete by 36 months. Conclusions—: Absorb demonstrates comparable long-term safety to XV in porcine coronary arteries with mild to moderate inflammation. Although Absorb was associated with greater percent stenosis relative to XV, expansile remodeling was observed after 12 months in Absorb with significantly greater lumen area at ≥36 months. Resorption is considered complete at 36 months.

14 October 2013 in European Heart Journal
Verified
Journal Article
Open access
PDF file
Kenichi SakakuraKenichi Sakakura
Kenichi Sakakura
MNMasataka Nakano
Masataka Nakano
FOFumiyuki Otsuka
Fumiyuki Otsuka
KYKazuyuki Yahagi
Kazuyuki Yahagi
RKRobert Kutys
Robert Kutys
RVRenu Virmani
Renu Virmani
The aim of our study was to investigate chronic total occlusion (CTO) in human coronary arteries to clarify the difference between CTO with prior coronary artery bypass graft (CABG) and those without prior CABG. A total of 95 CTO lesions from 82 patients (61.6 ± 14.0 years, male 87.8%) were divided into the following three groups: CTO with CABG (n = 34) (CTO+CABG), CTO without CABG—of long-duration (n = 49) (LD-CTO) and short-duration (n = 12) (SD-CTO). A histopathological comparison of the plaque characteristics of CTO, proximal and distal lumen morphology, and negative remodelling between groups was performed. A total of 1127 sections were evaluated. Differences in plaque characteristics were observed between groups as follows: necrotic core area was highest in SD-CTO (18.6%) (LD-CTO: 7.8%; CTO+CABG: 4.5%; P = 0.02); calcified area was greatest in CTO+CABG (29.2%) (LD-CTO: 16.8%; SD-CTO: 12.1%; P = 0.009); and negative remodelling was least in SD-CTO [remodelling index (RI) 0.86] [CTO+CABG (RI): 0.72 and LD-CTO (RI): 0.68; P < 0.001]. Approximately 50% of proximal lumens showed characteristics of abrupt closure, whereas the majority of distal lumen patterns were tapered (79%) (P < 0.0001). These pathological differences in calcification, negative remodelling, and presence of necrotic core along with proximal and distal tapering, which has been associated with greater success, help explain the differences in success rates of percutaneous coronary intervention in CTO patients with and without CABG.