The diagnostic yields and safety profiles of transbronchial lung biopsy have not been evaluated in inexperienced physicians using the combined modality of radial probe endobronchial ultrasound and a guide sheath (EBUS-GS). This study assessed the utility and safety of EBUS-GS during the learning phase by referring to a database of performed EBUS-GS procedures. From December 2015 to January 2017, all of the consecutive patients who underwent EBUS-GS were registered. During the study period, two physicians with no previous experience performed the procedure. To assess the diagnostic yields, learning curve, and safety profile of EBUS-GS performed by these inexperienced physicians, the first 100 consecutive EBUS-GS procedures were included in the evaluation. The overall diagnostic yield of EBUS-GS performed by two physicans in 200 patients with a peripheral lung lesion was 73.0%. Learning curve analyses showed that the diagnostic yields were stable, even when the procedure was performed by beginners. Complications related to EBUS-GS occurred in three patients (1.5%): pneumothorax developed in two patients (1%) and resolved spontaneously without chest tube drainage; another patient (0.5%) developed a pulmonary infection after EBUS-GS. There were no cases of pneumothorax requiring chest tube drainage, severe hemorrhage, respiratory failure, premature termination of the procedure, or procedure-related mortality. EBUS-GS is a safe and stable procedure with an acceptable diagnostic yield, even when performed by physicians with no previous experience.
Background: Detection of the epidermal growth factor receptor (EGFR) T790M mutation using plasma samples has been considered simple and non-invasive, but the relatively high false negative results lead to additional tissue sampling in some patients. Until now, the characteristics of patients who prefer liquid biopsy have not yet been established. Methods: To evaluate the favorable conditions for the detection of T790M mutations using plasma samples, a multicenter retrospective study was performed between May 2018 and December 2021. Patients whose T790M mutation was detected in a plasma sample were classified as the plasma positive group. Study subjects with a T790M mutation not detected in a plasma sample but only in a tissue sample were grouped as the plasma false negative group. Results: Plasma positive and plasma false negative groups were found in 74 and 32 patients, respectively. As a result, 40% of patients with one or two metastatic organs at the time of re-biopsy had false negative plasma sample results, and 69% of patients with three or more metastatic organs at the time of re-biopsy had positive plasma results. In multivariate analysis, three or more metastatic organs at initial diagnosis were independently associated with the detection of a T790M mutation using plasma samples. Conclusion: Our results demonstrated that the detection rate of a T790M mutation using plasma samples was related to the tumor burden, particularly to the number of metastatic organs.
Radial probe endobronchial ultrasound (RP-EBUS) accurately locates peripheral lung lesions (PLLs) during transbronchial biopsy (TBB). We performed an updated meta-analysis of the diagnostic yield of TBB for PLLs using RP-EBUS to generate recommendations for the development of the Korean Association of Lung Cancer guidelines. We systematically searched MEDLINE and EMBASE (from Jan 2013 to Dec 2022), and performed a meta-analysis using R software. The diagnostic yield was evaluated by dividing the number of successful diagnoses by the total lesion number. Subgroup analysis was performed to identify related factors. Forty-one studies with a total of 13,133 PLLs were included. The pooled diagnostic yield of RP-EBUS was 0.72 (95% confidence interval [CI], 0.70-0.75). Significant heterogeneity was observed among studies (χ2, 292.38; p<0.01; I2, 86.4%). In a subgroup analysis, there was a significant difference in diagnostic yield based on RP-EBUS findings (within, adjacent to, invisible), with a risk ratio of 1.45 (95%CI, 1.23-1.72) between within and adjacent to, 4.20 (95% CI, 1.89-9.32) between within and invisible, and 2.59 (95% CI, 1.32-5.01) between adjacent to and invisible. There was a significant difference in diagnostic yield based on lesion size, histologic diagnosis, computed tomography (CT) bronchus sign, lesion character, and location from the hilum. The overall complication rate of TBB with RP-EBUS was 6.8% (bleeding, 4.5%; pneumothorax, 1.4%). Our study showed that TBB with RP-EBUS is an accurate diagnostic tool for PLLs with good safety profiles, especially for PLLs with within orientation on RP-EBUS or positive CT bronchus sign.
Myelolipoma is a rare benign tumor composed of mature adipose and hematopoietic tissues. Most myelolipomas are found in the adrenal glands, whereas intrathoracic myelolipoma is extremely rare. In particular, bronchial myelolipoma without the involvement of lung parenchyma has never been reported. A previously healthy 38-year-old male developed dyspnea and a productive cough. Computed tomography revealed an endobronchial mass at the right bronchus intermedius and subsequent atelectasis of the right middle and lower lobes. Flexible bronchoscopy found a total obstruction of the right bronchus intermedius due to an endobronchial tumor. Using a rigid bronchoscope, the endobronchial tumor was resected and the base of the tumor was additionally ablated with a diode laser to prevent recurrence. The removed endobronchial tumor was a 13 mm × 20 mm-sized oval-shaped mass and was pathologically diagnosed as bronchial myelolipoma. Chest radiographs, obtained on the day following the procedure, showed an improvement of atelectasis, and accompanying symptoms were immediately improved. Follow-up bronchoscopy performed after 12 months evidenced no recurrence of the bronchial myelolipoma. We used bronchoscopic intervention in patients with solitary bronchial myelolipoma and there was no evidence of recurrence.
Background: Acute eosinophilic pneumonia (AEP) is a rare acute respiratory disease accompanied by fever, shortness of breath, and cough. Although the pathogenesis of the disease is not yet established, the patient’s condition improves with a rapid therapeutic response to systemic corticosteroids. Conventional cigarettes or heat-not-burn cigarettes are the most common cause of AEP among young people. Case Presentation: A 22-year-old woman with dyspnea, cough, and fever did not improve after visiting the local medical center and was admitted to the emergency room. The patient denied having any recent travel history or insect bites. She was treated with appropriate antibiotics according to the community acquired pneumonia, but there was no improvement. Chest radiography showed bilateral patches of pulmonary infiltration, and chest computed tomography revealed bilateral multifocal patchy consolidations with multiple small nodular ground-glass opacities and interlobular septal thickening. The bronchoalveolar lavage result was dominantly eosinophilic. The patient’s condition improved rapidly after the use of intravenous methylprednisolone and then a change to oral methylprednisolone. Finally, the patient was hospitalized for 9 days, and the duration of use of methylprednisolone including outpatient visits was 14 days. Results: The early treatment of AEP yields a good prognosis, but since the symptoms of AEP are similar to those of infectious diseases such as community-acquired pneumonia, physicians should be meticulous in differentiating AEP from other diseases. Conclusions: Since AEP shows a good response to steroids, early detection using an appropriate diagnostic method is recommended. In addition, there should be strong education against smoking in any form.
Anhydrous ammonia is a commonly used chemical in industry. Ammonia gas inhalation causes thermal injuries and alkali burns in the airway and lung parenchyma. Previous case reports have stated that respiratory sequelae after acute ammonia inhalation burns were associated with structural lung disease, such as bronchiectasis or interstitial lung disease. We herein report two cases of long-term sequelae with persistent airflow limitation after ammonia inhalation burns.