Bo Xu

Dr. Bo Xu


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2021 in The Lancet
Verified
Journal Article
Closed access
BXBo Xu
Bo Xu
STShengxian Tu
Shengxian Tu
LSLei Song
Lei Song
ZJZening Jin
Zening Jin
BYBo Yu
Bo Yu
GSGregg W Stone
Gregg W Stone

11 September 2019 in European Heart Journal
Verified
Journal Article
Open access
PDF file
DGDaniele Giacoppo
Daniele Giacoppo
FAFernando Alfonso
Fernando Alfonso
BXBo Xu
Bo Xu
BCBimmer E P M Claessen
Bimmer E P M Claessen
TATom Adriaenssens
Tom Adriaenssens
RBRobert A Byrne
Robert A Byrne
Consensus is lacking regarding the best treatment for coronary in-stent restenosis (ISR). The two most effective treatments are angioplasty with paclitaxel-coated balloon (PCB) and repeat stenting with drug-eluting stent (DES) but individual trials were not statistically powered for clinical endpoints, results were heterogeneous, and evidence about comparative efficacy and safety in relevant subsets was limited. The Difference in Anti-restenotic Effectiveness of Drug-eluting stent and drug-coated balloon AngiopLasty for the occUrrence of coronary in-Stent restenosis (DAEDALUS) study was a comprehensive, investigator-initiated, collaborative, individual patient data meta-analysis comparing angioplasty with PCB alone vs. repeat stenting with DES alone for the treatment of coronary ISR. The protocol was registered with PROSPERO (CRD42017075007). All 10 available randomized clinical trials were included with 1976 patients enrolled, 1033 assigned to PCB and 943 to DES. At 3-year follow-up, PCB was associated with a significant increase in the risk of target lesion revascularization (TLR) compared with DES [hazard ratio (HR) 1.32, 95% CI 1.02–1.70, P = 0.035; number-needed-to-harm 28.5]. There was a significant interaction between treatment effect and type of restenosed stent (P = 0.029) with a more marked difference in patients with DES-ISR and comparable effects in patients with bare-metal stent-ISR. At 3-year follow-up, the primary safety endpoint of all-cause death, myocardial infarction, or target lesion thrombosis was comparable between treatments (HR 0.80, 95% CI 0.58–1.09, P = 0.152). A pre-specified subgroup analysis indicated a significant interaction between treatment effect and type of DES used to treat ISR (P = 0.033), with a lower incidence of events associated with PCB compared with first-generation DES and similar effect between PCB and second-generation DES (HR 1.06, 95% CI 0.71–1.60, P = 0.764). Long-term all-cause mortality was similar between PCB and DES (HR 0.81, 95% CI 0.53–1.22, P = 0.310); results were consistent comparing PCB and non-paclitaxel-based DES (HR 1.42, 95% CI 0.80–2.54, P = 0.235). Myocardial infarction and target lesion thrombosis were comparable between treatments. In patients with coronary ISR, repeat stenting with DES is moderately more effective than angioplasty with PCB at reducing the need for TLR at 3 years. The incidence of a composite of all-cause death, myocardial infarction, or target lesion thrombosis was similar between groups. The rates of individual endpoints, including all-cause mortality, were not significantly different between groups.

1 December 2018 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
YTYida Tang
Yida Tang
SQShubin Qiao
Shubin Qiao
XSXi Su
Xi Su
YCYundai Chen
Yundai Chen
ZJZening Jin
Zening Jin
JWJijia Wang
Jijia Wang

20 August 2020 in European Heart Journal
Verified
Journal Article
Closed access
SLShen Lin
Shen Lin
ZLZhigang Li
Zhigang Li
BFBowen Fu
Bowen Fu
SCSipeng Chen
Sipeng Chen
XLXi Li
Xi Li
ZZZhe Zheng
Zhe Zheng
Aims: Facial features were associated with increased risk of coronary artery disease (CAD). We developed and validated a deep learning algorithm for detecting CAD based on facial photos. Methods and results: We conducted a multicentre cross-sectional study of patients undergoing coronary angiography or computed tomography angiography at nine Chinese sites to train and validate a deep convolutional neural network for the detection of CAD (at least one ≥50% stenosis) from patient facial photos. Between July 2017 and March 2019, 5796 patients from eight sites were consecutively enrolled and randomly divided into training (90%, n = 5216) and validation (10%, n = 580) groups for algorithm development. Between April 2019 and July 2019, 1013 patients from nine sites were enrolled in test group for algorithm test. Sensitivity, specificity, and area under the receiver operating characteristic curve (AUC) were calculated using radiologist diagnosis as the reference standard. Using an operating cut point with high sensitivity, the CAD detection algorithm had sensitivity of 0.80 and specificity of 0.54 in the test group; the AUC was 0.730 (95% confidence interval, 0.699–0.761). The AUC for the algorithm was higher than that for the Diamond–Forrester model (0.730 vs. 0.623, P < 0.001) and the CAD consortium clinical score (0.730 vs. 0.652, P < 0.001). Conclusion: Our results suggested that a deep learning algorithm based on facial photos can assist in CAD detection in this Chinese cohort. This technique may hold promise for pre-test CAD probability assessment in outpatient clinics or CAD screening in community. Further studies to develop a clinical available tool are warranted.

5 October 2021 in Circulation
Verified
Journal Article
Closed access
PDF file
MTMeice Tian
Meice Tian
XWXianqiang Wang
Xianqiang Wang
HSHansong Sun
Hansong Sun
WFWei Feng
Wei Feng
YSYunhu Song
Yunhu Song
SHShengshou Hu
Shengshou Hu
Background: Vein graft occlusion is deemed a major challenge in coronary artery bypass grafting. Previous studies implied that the no-touch technique for vein graft harvesting could reduce occlusion rate compared with the conventional approach; however, evidence on the clinical benefit and generalizability of the no-touch technique is scare. Methods: From April 2017 to June 2019, we randomly assigned 2655 patients undergoing coronary artery bypass grafting at 7 hospitals in a 1:1 ratio to receive no-touch technique or conventional approach for vein harvesting. The primary outcome was vein graft occlusion on computed tomography angiography at 3 months and the secondary outcomes included 12-month vein graft occlusion, recurrence of angina, and major adverse cardiac and cerebrovascular events. The generalized estimate equation model was used to account for the cluster effect of grafts from the same patient. Results: During the follow-up, 2533 (96.0%) participants received computed tomography angiography at 3 months after coronary artery bypass grafting and 2434 (92.2%) received it at 12 months. The no-touch group had significantly lower rates of vein graft occlusion than the conventional group both at 3 months (2.8% versus 4.8%; odds ratio, 0.57 [95% CI, 0.41–0.80]; P <0.001) and 12 months (3.7% versus 6.5%; odds ratio, 0.56 [95% CI, 0.41–0.76]; P <0.001). Recurrence of angina was also less common in the no-touch group at 12 months (2.3% versus 4.1%; odds ratio, 0.55 [95% CI, 0.35–0.85]; P <0.01). Rates of major adverse cardiac and cerebrovascular events were of no significant difference between the 2 groups. The no-touch technique was associated with higher rates of leg wound surgical interventions at 3-month follow-up (10.3% versus 4.3%; odds ratio, 2.55 [95% CI, 1.85–3.52]; P <0.001). Conclusions: Compared with the conventional vein harvesting approach in coronary artery bypass grafting, the no-touch technique significantly reduced the risk of vein graft occlusion and improved patient prognosis. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03126409.

30 December 2019 in European Heart Journal
Verified
Journal Article
Closed access
Shengxian TuShengxian Tu
Shengxian Tu
JWJelmer Westra
Jelmer Westra
JAJulien Adjedj
Julien Adjedj
DDDaixin Ding
Daixin Ding
FLFuyou Liang
Fuyou Liang
WWWilliam Wyns
William Wyns
Fractional flow reserve (FFR) and instantaneous wave-free ratio are the present standard diagnostic methods for invasive assessment of the functional significance of epicardial coronary stenosis. Despite the overall trend towards more physiology-guided revascularization, there remains a gap between guideline recommendations and the clinical adoption of functional evaluation of stenosis severity. A number of image-based approaches have been proposed to compute FFR without the use of pressure wire and induced hyperaemia. In order to better understand these emerging technologies, we sought to highlight the principles, diagnostic performance, clinical applications, practical aspects, and current challenges of computational physiology in the catheterization laboratory. Computational FFR has the potential to expand and facilitate the use of physiology for diagnosis, procedural guidance, and evaluation of therapies, with anticipated impact on resource utilization and patient outcomes.