The objective of the study was to evaluate the oncological and functional results of transoral laser microsurgery (TLM) in patients with supraglottic laryngeal squamous cell carcinoma. Between June 1980 and December 2006, 277 patients with squamous cell supraglottic carcinoma of all stages were treated by primary carbon dioxide laser microsurgery. All treatments were performed with curative intention. The goal was the complete tumor removal with preservation of functionally important structures of the larynx. The administered treatment was exclusively TLM with or without selective or modified radical neck dissection in 215 cases (78 %); TLM with postoperative radiotherapy was performed in 62 cases (22 %). Data were analyzed using the Kaplan–Meier method. The median follow-up was 65 months. We achieved a 5-year local control rate of 85 % for pT1/pT2, 82 % for pT3, and 76 % for pT4. The 5-year overall, recurrence-free and disease-specific survival rates for stages I and II were 76, 81, and 92 %, for stages III and IVa 59, 65, and 81 %, respectively. With respect to local control and survival, these results are comparable with the results achieved by conventional partial and total resection of the larynx, while being superior to primary (chemo)radiotherapy. Transoral laser microsurgery results in a low morbidity, rapid recovery, and superior function compared with standard therapy.
20 June 2013 in International Journal of Audiology
Objective: Exposure to loud noise can impair cochlear microcirculation and cause noise-induced hearing loss (NIHL). TNF-α signaling has been shown to be activated in NIHL and to control spiral modiolar artery vasoconstriction that regulates cochlear microcirculation. It was the aim of this experimental study to analyse the effects of the TNF-α inhibitor etanercept on cochlear microcirculation and hearing threshold shift in NIHL in vivo. Design: After assessment of normacusis using ABR, loud noise (106 dB SPL, 30 minutes) was applied on both ears in guinea pigs. Etanercept was administered systemically after loud noise exposure while control animals received a saline solution. In vivo fluorescence microscopy of strial capillaries was performed after surgical exposure of the cochlea for microcirculatory analysis. ABR measurements were derived from the contralateral ear. Study sample: Guinea pigs (n = 6, per group). Results: Compared to controls, cochlear blood flow in strial capillary segments was significantly increased in etanercept-treated animals. Additionally, hearing threshold was preserved in animals receiving the TNF-α inhibitor in contrast to a significant threshold raising in controls. Conclusions: TNF-α inhibition using etanercept improves cochlear microcirculation and protects hearing levels after loud noise exposure and appears as a promising treatment strategy for human NIHL.
Objective To review functional results and quality of life of the first patients implanted with a newly introduced bone conduction implant system. Study Design Retrospective chart analysis of 6 patients (6 ears) implanted for conductive hearing loss (CHL) and mixed hearing loss (MHL) in 1 tertiary referral center between July 2012 and February 2013. Methods Implantation of a new bone conduction hearing device. Pure tone audiometry (air conduction and bone conduction thresholds, pure tone average, air-bone gap, and functional gain), speech audiometry (Freiburg Monosyllabic Test), intraoperative and postoperative complication rate, and patient satisfaction (Glasgow benefit inventory [GBI]) were assessed. Results Air-conduction pure tone average (PTA) was 58.8 ± 8.2 dB HL. Unaided average air-bone gap (ABG) was 33.3 ± 6.2 dB. Aided air-conduction PTA in sound field was 25.2 ± 5.1 dB HL. Aided average ABG was -0.3 ± 7.3 dB. Average functional gain was 33.6 ± 7.2 dB. Mean improvement of GBI was +36.1. No intraoperative complications occurred. During a follow-up period of 8.5 ± 2.2 months, no device failure and no need for revision surgery occurred. Conclusion Audiometric results of the new bone conduction hearing system are satisfying and comparable to the results of devices that have been applied previously for CHL and MHL. Intraoperatively and postoperatively, no complications were noted. Level of Evidence 4 (Individual retrospective cohort study)