Kai Thorsten Laser

Dr. Kai Thorsten Laser

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 October 2009 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
KLKai Thorsten Laser
Kai Thorsten Laser
NHNikolaus Alexander Haas
Nikolaus Alexander Haas
NJNadine Jansen
Nadine Jansen
RSRainer Schäffler
Rainer Schäffler
JAJorge Roberto Palacios Argueta
Jorge Roberto Palacios Argueta
DKDeniz Kececioglu
Deniz Kececioglu

1 October 2016 in International Journal of Cardiology
Verified
Journal Article
Closed access
ZMZora Meyer
Zora Meyer
MFM. Fischer
M. Fischer
JKJ. Koerfer
J. Koerfer
KLKai Thorsten Laser
Kai Thorsten Laser
DKD. Kececioglu
D. Kececioglu
DHDr. Nikolaus HAAS
Dr. Nikolaus HAAS

1 October 2014 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
KLKai Thorsten Laser
Kai Thorsten Laser
JHJan-Pit Horst
Jan-Pit Horst
PBPeter Barth
Peter Barth
AKAndrea Kelter-Klöpping
Andrea Kelter-Klöpping
NHNikolaus Alexander Haas
Nikolaus Alexander Haas
HKHermann Körperich
Hermann Körperich

16 December 2009 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
PDF file
KLKai Thorsten Laser
Kai Thorsten Laser
MBMiriam Bunge
Miriam Bunge
PHPia Hauffe
Pia Hauffe
JAJorge Roberto Palacios Argueta
Jorge Roberto Palacios Argueta
AKAndrea Kelter-Klöpping
Andrea Kelter-Klöpping
HKHermann Körperich
Hermann Körperich
To assess the accuracy of different hardware and software settings for left ventricular (LV) volume quantification in children using real-time three-dimensional echocardiography (RT3DE). The impact of different matrix transducers (IE 33, X3-1 and VIVID 7, V3) and quantification software settings [TOMTEC; contour-finding activity (tCFA) values ranging from 30 to 70 U] on the accuracy of LV indices was tested in 24 healthy children/adolescents (median = 12.6 years) and 25 paediatric patients with Tetralogy-of-Fallot (TOF) (median = 7.3 years) with abnormally shaped ventricles. RT3DE was compared with cardiovascular magnetic resonance (CMR) volumetry as reference. Best agreement (Bland–Altman analysis) was achieved using a tCFA value of 30 U. Applying the V3 device, end-diastolic volume (EDV) and end-systolic volume (ESV) were underestimated by 14.8 ± 10.6% (mean ± SD) and 11.2 ± 16.3%, respectively ( r = 9.42, P < 0.001 and r = 0.937, P = 0.003); with the X3-1 system 24.2 ± 11.0 and 14.6 ± 15.2%, respectively ( r = 0.951, P < 0.001 and r = 0.912, P = 0.001). Negligible differences <1% ( P = n.s.) between both transducers were detected applying a tCFA value of 70 U but with significant underestimation (EDV: ∼35%, P < 0.001; ESV: ∼26%, P < 0.001) compared with CMR. EDV and ESV of TOF patients were underestimated by 3.2 ± 15.4 and 8.1 ± 22.6%, respectively. Intra- and interobserver variability was <4%. In contrast to recommendations of the manufacturer, data sets from both RT3DE transducers showed acceptable agreement to CMR for volumetric parameters only for low tCFA. Fine-tuning of software settings is mandatory to improve accuracy.

Verified
Journal Article
Open access
PDF file
Andreas BrodehlAndreas Brodehl
Andreas Brodehl
Alexey MeshkovAlexey Meshkov
Alexey Meshkov
RMRoman Myasnikov
Roman Myasnikov
AKAnna Kiseleva
Anna Kiseleva
OKOlga Kulikova
Olga Kulikova
Hendrik MiltingHendrik Milting
Hendrik Milting
About 50% of patients with arrhythmogenic cardiomyopathy (ACM) carry a pathogenic or likely pathogenic mutation in the desmosomal genes. However, there is a significant number of patients without positive familial anamnesis. Therefore, the molecular reasons for ACM in these patients are frequently unknown and a genetic contribution might be underestimated. Here, we used a next-generation sequencing (NGS) approach and in addition single nucleotide polymor-phism (SNP) arrays for the genetic analysis of two independent index patients without familial medical history. Of note, this genetic strategy revealed a homozygous splice site mutation (DSG2–c.378+1G>T) in the first patient and a nonsense mutation (DSG2–p.L772X) in combination with a large deletion in DSG2 in the second one. In conclusion, a recessive inheritance pattern is likely for both cases, which might contribute to the hidden medical history in both families. This is the first report about these novel loss-of-function mutations in DSG2 that have not been previously identi-fied. Therefore, we suggest performing deep genetic analyses using NGS in combination with SNP arrays also for ACM index patients without obvious familial medical history. In the future, this finding might has relevance for the genetic counseling of similar cases.

13 June 2018 in Journal of the American Society of Echocardiography
Verified
Journal Article
Closed access
PDF file
KLKai Thorsten Laser
Kai Thorsten Laser
AKAyşe Karabiyik
Ayşe Karabiyik
HKHermann Körperich
Hermann Körperich
JHJan-Pit Horst
Jan-Pit Horst
PBPeter Barth
Peter Barth
UHUlrike Herberg
Ulrike Herberg