Alexandra Maria Isabel Trefilov

Dr. Alexandra Maria Isabel Trefilov

Lasers, National Institute for Laser Plasma and Radiation Physics, Bucharest, Bucureşti, Romania
orcid
Senior Researcher

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2018 in Journal of Power Sources
Verified
Journal Article
Closed access
Athanasios TiliakosAthanasios Tiliakos
Athanasios Tiliakos
ATAlexandra Maria Isabel Trefilov
Alexandra Maria Isabel Trefilov
ETEugenia Tanasӑ
Eugenia Tanasӑ
ABAdriana Balan
Adriana Balan
ISIoan Stamatin
Ioan Stamatin

1 April 2017 in International Journal of Hydrogen Energy
Verified
Journal Article
Closed access
ATAlexandra Maria Isabel Trefilov
Alexandra Maria Isabel Trefilov
Athanasios TiliakosAthanasios Tiliakos
Athanasios Tiliakos
ESElena C. Serban
Elena C. Serban
CCCătălin Ceaus
Cătălin Ceaus
SIStefan-Marian Iordache
Stefan-Marian Iordache
ABAdriana Balan
Adriana Balan

26 November 2021 in Polymers
Verified
Journal Article
Open access
PDF file
ATAlexandra Maria Isabel Trefilov
Alexandra Maria Isabel Trefilov
Adriana Elena BalanAdriana Elena Balan
Adriana Elena Balan
ISIoan Stamatin
Ioan Stamatin
Organic resorcinol–formaldehyde (RF) hydrogels were introduced into a hybrid cation-exchange membrane in order to enhance its following properties: water uptake, thermal stability, and ionic conductivity. This study was aimed to investigate the modifications induced by the RF organic clusters that form a uniform distributed network within the perflourosulfonated acid (PFSA) matrix. RF concentration was controlled by resorcinol and formaldehyde impregnation time using water or ethanol solvents. The specific morphological and structural properties were characterized by atomic force microscopy, UV–Vis, and Fourier transform infrared spectroscopy. Thermo-gravimetric analysis was employed to study the thermal stability and degradation processes of the composite membranes. Proton conductivity, as a function of relative humidity (RH) at 80 °C, was measured using in-plane four-point characterization technique. Compared to the pristine membrane, the PFSA–RF hybrid membranes showed improved thermal stability at up to 46 °C and higher ionic conductivity for low RF content, especially at low relative humidity, when using ethanol-based solvents. Single fuel cell testing on RF-based membrane–electrode assembly revealed impeccable fuel crossover and power performance at 80 °C and 40% relative humidity, delivering a 76% increase in power density compared to a reference assembled with a pristine membrane and the same catalyst loadings.

30 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
IVIONESCU VIOREL
IONESCU VIOREL
Adriana Elena BalanAdriana Elena Balan
Adriana Elena Balan
ATAlexandra Maria Isabel Trefilov
Alexandra Maria Isabel Trefilov
ISIoan Stamatin
Ioan Stamatin
The microporous layer (MPL) constitutes a critical component of the gas diffusion layer within the membrane electrode assembly (MEA) of a proton exchange membrane fuel cell (PEM FC). The MPL plays a fundamental role in various processes during FC operation: control of membrane humidification, heat distribution throughout the MEA, excess water removal from the cathode, and transportation of fuel to the reaction sites. Previously, we investigated the performance of a fuel cell unit employing an MPL based on laser-induced graphene (LIG) produced by the laser pyrolysis of polymeric (polyimide) substrates. The prototype LIG-based unit was tested over the typical range of relative humidity and temperature conditions. The polarization curves observed in that study displayed broad ohmic loss regions and high stability along the concentration loss regions, an interesting electrical behavior that justified developing the present voltage-current density study for the same FC prototype compared to one bearing a commercial pyrolytic carbon black MPL. The same operating conditions as in the first study were applied, in order to properly compare the performance efficiencies between the two systems; these are evaluated by considering the thermodynamic losses influence on the exergy efficiency, to exceed any limitations inherent in the classical energy efficiency analysis.

1 January 2016 in Energy Procedia
Verified
Journal Article
Open access
SIStefan-Marian Iordache
Stefan-Marian Iordache
ACA. Ciocanea
A. Ciocanea
ABA. Balan
A. Balan
ISIoan Stamatin
Ioan Stamatin
SBS. Budea
S. Budea
SVS. Voinea
S. Voinea
Hydrogen sulfide is an environmental pollutant and abundant in various sulfurous waters such as Black Sea. Hydrogen sulfide is in the same time a potential energetic materials as source for hydrogen production. In this respect, designing an appropriate fuel cell with proton exchange membranes (PEMFC) for hydrogen sulfide recovering from sulfurous water is challenge. This study reports a PEMFC with Pt/Pt-Ru catalysts and membrane with perflurosulfonic ionomer. PEMFC was run at different concentrations of hydrogen sulfide in water (50-150mg/L). Even though power densities are in the range microwatts the experimental set-up shows a promising perspective for sulfurous water treatment. A short overview on the actual state of the art in hydrogen sulfide recovering and potential applications of the fuel cells is presented in introduction

27 July 2025 in Materials
Verified
Journal Article
Open access
PDF file
ATAlexandra Maria Isabel Trefilov
Alexandra Maria Isabel Trefilov
Mihai OaneMihai Oane
Mihai Oane
Liviu DutaLiviu Duta
Liviu Duta
The Pennes bioheat equation is the most widely used model for describing heat transfer in living tissue during thermal exposure. It is derived from the classical Fourier law of heat conduction and assumes energy exchange between blood vessels and surrounding tissues. The literature presents various numerical methods for solving the bioheat equation, with exact solutions developed for different boundary conditions and geometries. However, analytical models based on this framework are rarely reported. This study aims to develop an analytical three-dimensional model using MATHEMATICA software, with subsequent mathematical validation performed through COMSOL simulations, to characterize heat transfer in biological tissues induced by laser irradiation under various therapeutic conditions. The objective is to refine the conventional bioheat equation by introducing three key improvements: (a) incorporating a non-Fourier framework for the Pennes equation, thereby accounting for the relaxation time in thermal response; (b) integrating Dirac functions and the telegraph equation into the bioheat model to simulate localized point heating of diseased tissue; and (c) deriving a closed-form analytical solution for the Pennes equation in both its classical (Fourier-based) and improved (non-Fourier-based) formulations. This paper investigates the nuanced relationship between the relaxation time parameter in the telegraph equation and the thermal relaxation time employed in the bioheat transfer equation. Considering all these aspects, the optimal thermal relaxation time determined for these simulations was 1.16 s, while the investigated thermal exposure time ranged from 0.01 s to 120 s. This study introduces a generalized version of the model, providing a more realistic representation of heat exchange between biological tissue and blood flow by accounting for non-uniform temperature distribution. It is important to note that a reasonable agreement was observed between the two modeling approaches: analytical (MATHEMATICA) and numerical (COMSOL) simulations. As a result, this research paves the way for advancements in laser-based medical treatments and thermal therapies, ultimately contributing to more optimized therapeutic outcomes.