Capillary refill time (CRT) is an internationally accepted indicator of peripheral circulation. The CRT is measured by applying compression to the fingernail for a few seconds, releasing it, and observing the process of refilling of blood at the fingertip. The international guidelines for the management of sepsis and septic shock 2021 contains an additional new recommendation for CRT measurement to determine the peripheral circulation statuses of adult patients with septic shock. However, the current CRT measurement method lacks objectivity. Previous studies have reported the development of measurement devices and video analysis systems, which involve complex measurement environment construction and assume only in-hospital measurements. In addition, since medical workers are limited in the number of carrying medical devices, devices that can be used to obtain multiple biometric indicators in a single measurement are needed. Hence, a prototype wearable CRT measurement device was developed in this study, and its feasibility was evaluated by comparing the agreement, intra-class correlation coefficient, and coefficient of variation with those of a CRT measurement device developed in the past. The results indicated that mean CRTs between measurement methods were agreement, with moderate or better intra-rater reliability and no difference in coefficient of variation. Therefore, the results indicate the feasibility of the proposed wearable CRT device.
Introduction: Capillary refill time (CRT) is an indicator of peripheral circulation and is recommended in the 2021 guidelines for treating and managing sepsis.Study Objective: This study developed a portable device to realize objective CRT measurement. Assuming that peripheral blood flow obstruction by the artery occlusion test (AOT) or venous occlusion test (VOT) increases the CRT, the cut-off value for peripheral circulatory failure was studied by performing a comparative analysis with CRT with no occlusion test (No OT).Methods: Fourteen (14) healthy adults (age: 20–26 years) participated in the study. For the vascular occlusion test, a sphygmomanometer was placed on the left upper arm of the participant in the supine position, and a pressure of 30mmHg higher than the systolic pressure was applied for AOT, a pressure of 60mmHg was applied for VOT, respectively, and no pressure was applied for No OT. The CRT was measured from the index finger of the participant’s left hand.Results: Experimental results revealed that CRT was significantly longer in the AOT and did not differ significantly in the VOT. The cut-off value for peripheral circulatory failure was found to be 2.88 seconds based on Youden’s index by using receiver operating characteristic (ROC) analysis with AOT as positive and No OT as negative.Conclusion: Significant results were obtained in a previous study on the evaluation of septic shock patients when CRT > three seconds was considered abnormal, and the cut-off value for peripheral circulatory failure in the current study validated this.
Capillary refill time (CRT) is widely used in pediatric and emergency medicine as an indicator of peripheral circulation. CRT is defined as the time required for the skin to return to its original color after external compression is applied and then released. In current clinical practice, however, CRT assessment remains qualitative and relies heavily on the magnitude and consistency of compression applied by the measurer, as well as on subjective visual color perception, which together result in limited measurement reliability. To improve measurement reliability, several quantitative CRT measurement devices have been developed. Nevertheless, these devices are dedicated specifically to CRT measurement, which limits their versatility and complicates clinical implementation. In this study, we developed a simple and quantitative CRT measurement method using a smartphone. Based on skin color changes captured by the rear camera, we proposed a method to assess the adequacy of the applied compression force and implemented an application to calculate CRT. In addition, we investigated an algorithm to reduce the influence of pulse waves observed in the post-release waveform, enabling more stable CRT estimation. Furthermore, a dedicated smartphone case was designed to immobilize the finger during measurement, thereby improving measurement reliability. The feasibility of the proposed method was evaluated by examining agreement with a previously developed CRT measurement device and by assessing intraexaminer reliability, confirming its effectiveness.
3 February 2023 in Journal of Plastic, Reconstructive & Aesthetic Surgery