Under extreme events, distribution systems may suffer blackouts and numerous restoration tasks will compete for limited crews and facilities. To enhance the resilience of distribution systems, multiple resources should be fully coordinated, coupling relationships between fault location, fault isolation, and service restoration should be considered, and flexible strategies should be formed for different situations faced by distribution systems. To this end, a comprehensive resilience-oriented fault location, fault isolation, and service restoration (RO-FLISR) method is proposed in this paper, where, the fault location, fault isolation, and service restoration under extreme events are comprehensively considered at the same time for the first time, and multiple resources are coordinated. Three basic modules are formulated in the RO-FLISR method, i.e., the possible faulted zone determination (PFZD) module which could determine all the possible faulted zones when there are multiple faults and DGs, the line patrolling (LP) module which supports the optimal scheme for line paroling based on crews, and the fault isolation and service restoration (FISR) module in which the operation of MSs and RCSs are coordinated for comprehensive fault isolation and service restoration. The modules are formulated as MILP models. Effectiveness of the proposed method is verified with the IEEE 123-bus system.
28 March 2019 in IET Generation, Transmission & Distribution
Fast load restoration based on network reconfiguration is a key step to enhance the resilience of distribution systems (DSs). For DSs equipped with remote‐controlled switches (RCSs), the reconfiguration can be completed promptly. However, when the branch is equipped with manual switches only, it cannot be operated immediately, and its post‐event state is determined by its pre‐event state. Considering these facts, this study proposes a unified two‐stage reconfiguration method for the resilience enhancement of DSs. In the pre‐event stage, the allocation of RCSs and the reconfiguration of the network are determined to prepare the system for a set of possible fault scenarios caused by upcoming extreme weather. In the post‐event stage, network reconfiguration based on the placed RCSs is performed for fast load restoration to minimise the loss of load expectation (LOLE). A new mathematical expression is proposed to ensure the radial operation of DSs with islanded DSs and islanded microgrids. To improve the computational efficiency, the scenario decomposition algorithm is employed to decompose the proposed model into several subproblems, which can be solved in parallel. The results show that the proposed method can significantly reduce the LOLE caused by extreme weather events, thus enhancing the resilience of DSs.
The deep peak regulation of thermal units is an important measure for coping with significant wind power penetration. In this paper, based on interval optimization, a novel multi-objective unit commitment method is proposed considering the deep peak regulation of thermal units. In the proposed method, a thermal power cost model was developed to accurately determine the economic performance of three different peak regulation scenarios, particularly of the deep peak regulation scenario. The midpoint and width of the cost interval are simultaneously considered in the optimization process. The non-dominated sorting GA-II (NSGA-II) algorithm was incorporated into the model for a coordinated control of the midpoint and width of the obtained cost interval for further optimization. Considering that significant wind penetration results in greater nodal variations, the affine arithmetic was employed to solve nodal uncertainties, so that all system variations can be addressed. The method proposed in this paper was validated by a modified IEEE-39 bus system. The results showed that it serves as a useful tool for power dispatchers to obtain robust and economic solutions at different wind power prediction accuracies.
23 April 2024 in IEEE Transactions on Power Systems
Security analysis methods based on security region (SR) play a pivotal role in power system analysis. The construction of security margin contributes towards the mining of geometric and physical characteristics of a practical dynamic SR (PDSR). The data-driven approach provides strong support for power system security analysis. However, poor interpretability and weak generalization ability of artificial intelligence method have hindered its application in power systems. Although the model-driven method can effectively analyze the internal mechanisms of physical models, improve their interpretability, and enhance the reliability of security margin assessment, its strong nonlinear structure and low computational efficiency limits its further application. This study first constructed a reliable security margin based on the characteristics of the SR, and consequently obtained the critical operating interval based on a reliability indicator. Finally, data-driven method was used to modify the security margin of PDSR. The proposed method was validated on the New England 10-machine-39-node system and a practical system in China. The results confirmed its higher evaluation accuracy compared to existing methods. Further, it could effectively explain the model mechanism, providing key factors that affect the evaluation results. A PDSR with high accuracy and interpretability will facilitate the accurate formulation of transient stability assessment results, while increasing the response time for power system dispatch decision-making.
14 October 2023 in International Journal of Electrical Power & Energy Systems