Moonis Ally

Dr. Moonis Ally

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2015 in Applied Energy
Verified
Journal Article
Closed access
Moonis AllyMoonis Ally
Moonis Ally
JMJeffrey Munk
Jeffrey Munk
VBVan D. Baxter
Van D. Baxter
AGAnthony C. Gehl
Anthony C. Gehl

29 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
BSBo Shen
Bo Shen
Moonis AllyMoonis Ally
Moonis Ally
Heat pumps (HPs) are being developed with a new emphasis on cold climates. To lower the environmental impact of greenhouse gas (GHG) emissions, alternate low global warming potential (GWP) refrigerants must also replace the exclusive use of the refrigerant R410A, preferably without re-engineering the mechanical hardware. In this paper, we analyze the performance of four low-GWP alternative refrigerants (R32, R452B, R454B, and R466A) relative to the conventional R410A and draw conclusions on the relative performances for providing heating in cold climates based on the Air-Conditioning, Heating, and Refrigeration Institute (AHRI) 210/240 standard for two-speed heat pumps. The simulations are carried using the Department of Energy, Oak Ridge National Laboratory (DOE/ORNL) Heat Pump Design Model (HPDM), a well-known heating, ventilation, and air conditioning (HVAC) modeling and design tool in the public domain and the HVAC research and development community. The results of the simulation are further scrutinized using exergy analysis to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate low-GWP refrigerants to replace R410A using available compressors and system components, without compromising performance.

1 October 2019 in International Journal of Refrigeration
Verified
Journal Article
Closed access
Moonis AllyMoonis Ally
Moonis Ally
VSVishaldeep Sharma
Vishaldeep Sharma
KNKashif Nawaz
Kashif Nawaz

1 October 2015 in Applied Thermal Engineering
Verified
Journal Article
Closed access
Moonis AllyMoonis Ally
Moonis Ally
JMJeffrey Munk
Jeffrey Munk
VBVan D. Baxter
Van D. Baxter
AGAnthony C. Gehl
Anthony C. Gehl

1 April 2017 in International Journal of Refrigeration
Verified
Journal Article
Closed access
Moonis AllyMoonis Ally
Moonis Ally
VSVishaldeep Sharma
Vishaldeep Sharma
Omar AbdelazizOmar Abdelaziz
Omar Abdelaziz

12 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
AAAhmad Abuheiba
Ahmad Abuheiba
Moonis AllyMoonis Ally
Moonis Ally
BSBrennan Smith
Brennan Smith
AMAyyoub Momen
Ayyoub Momen
This paper demonstrates a new method by which the energy storage density of compressed air systems is increased by 56.8% by changing the composition of the compressed gas to include a condensable component. A higher storage density of 7.33 MJ/m3 is possible using a mixture of 88% CO2 and 12% N2 compared to 4.67 MJ/m3 using pure N2. This ratio of gases representing an optimum mixture was determined through computer simulations that considered a variety of different proportions from pure CO2 to pure N2. The computer simulations are based on a thermodynamic equilibrium model that predicts the mixture composition as a function of volume and pressure under progressive compression to ultimately identify the optimal mixture composition (88% CO2 + 12% N2). The model and simulations predict that the optimal gas mixture attains a higher energy storage density than using either of the pure gases.