Takahiro Tsuboyama

Dr. Takahiro Tsuboyama

Osaka University, Ōsaka, Japan
orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2023 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
FTFuminari Tatsugami
Fuminari Tatsugami
TNTakeshi Nakaura
Takeshi Nakaura
MYMasahiro Yanagawa
Masahiro Yanagawa
SFShohei Fujita
Shohei Fujita
KKKoji Kamagata
Koji Kamagata
SNShinji Naganawa
Shinji Naganawa

1 January 2013 in Journal of Computer Assisted Tomography
Verified
Journal Article
Closed access
HJHiroshi Juri
Hiroshi Juri
MMMitsuru Matsuki
Mitsuru Matsuki
YIYuki Inada
Yuki Inada
TTTakahiro Tsuboyama
Takahiro Tsuboyama
SKSeishi Kumano
Seishi Kumano
YNYoshifumi Narumi
Yoshifumi Narumi
The aim of this study was to evaluate the image quality of low-dose computed tomographic (CT) urography using adaptive iterative dose reduction 3-dimensional (AIDR 3D) compared with routine-dose CT using filtered back projection (FBP). Thirty patients underwent low- and routine-dose CT scans in the nephrographic and excretory phases of CT urography. Low-dose CT was reconstructed with AIDR 3D, and routine-dose CT was reconstructed with FBP. In quantitative analyses, image noises were measured on the renal cortex, aorta, retroperitoneal fat, and psoas muscle in both CT scans and compared. Qualitative analyses of the urinary system were performed in both CT scans and compared. These results were compared on the basis of the body mass index (BMI) of the patients. The CT dose index (CTDIvol) was measured, and the dose reduction was calculated. In quantitative analyses, image noises in all organs on low-dose CT were less than those on routine-dose CT in both phases independently of the patient's BMI. There were no statistical differences between low- and routine-dose CT for diagnostic acceptability on all urinary systems in both phases independently of the patient's BMI. The average CTDIvol on routine-dose CT was 14.5 mGy in the nephrographic phase and 9.2 mGy in the excretory phase. The average CTDIvol on low-dose CT was 4.2 mGy in the nephrographic phase and 2.7 mGy in the excretory phase. Low-dose CT urography using AIDR 3D can offer diagnostic acceptability comparable with routine-dose CT urography with FBP with approximately 70% dose reduction.

1 November 2022 in RadioGraphics
Verified
Journal Article
Closed access
TTTakahiro Tsuboyama
Takahiro Tsuboyama
KSKazuaki Sato
Kazuaki Sato
TOTakashi Ota
Takashi Ota
ヒフヒデユキ フクイ
ヒデユキ フクイ
HOHiromitsu Onishi
Hiromitsu Onishi
NTNoriyuki Tomiyama
Noriyuki Tomiyama
Knowledge of the MRI features of borderline epithelial ovarian tumor can aid in preoperative diagnosis; however, several benign and malignant tumors can mimic borderline tumors and pose diagnostic ... Borderline epithelial ovarian tumors are a distinct pathologic entity characterized by increased epithelial proliferation and nuclear atypia, but without frank stromal invasion. Borderline tumor (B... Created with BioRender.com

7 January 2022 in Investigative Radiology
Verified
Journal Article
Closed access
TTTakahiro Tsuboyama
Takahiro Tsuboyama
HOHiromitsu Onishi
Hiromitsu Onishi
ANAtsushi Nakamoto
Atsushi Nakamoto
KOKazuya Ogawa
Kazuya Ogawa
YKYoshihiro Bs Koyama
Yoshihiro Bs Koyama
NTNoriyuki Tomiyama
Noriyuki Tomiyama
Objective: This study aimed to evaluate the effects of deep learning (DL) reconstruction and a postprocessing sharpening filter on the image quality of single-shot fast spin-echo (SSFSE) T2-weighted imaging (T2WI) of the uterus. Materials and Methods: Fifty consecutive patients who underwent pelvic magnetic resonance imaging were included. Parasagittal T2WI with a slice thickness of 4 mm was obtained with the periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) and SSFSE sequences (mean scan time, 204 and 22 seconds, respectively). The following 3 types of SSFSE images were reconstructed, and the signal-to-noise ratio (SNR) and tissue contrast were assessed: conventional reconstruction (SSFSE-C), DL reconstruction (SSFSE-DL), and DL with a sharpening filter (SSFSE-DLF). Three radiologists independently assessed image quality, and area under the visual grading characteristics curve (AUCVGC) analysis was performed to compare the SSFSE and PROPELLER images. Results: Compared with that of the PROPELLER images, the SNR of the SSFSE-C, SSFSE-DL, and SSFSE-DLF images was significantly lower (P < 0.05), significantly higher (P < 0.05), and equivalent, respectively. The SSFSE-DL images exhibited significantly lower contrast between the junctional zone and myometrium than those obtained with the other sequences (P < 0.05). In qualitative comparisons with the PROPELLER images, all 3 SSFSE sequences, SSFSE-DL, and SSFSE-DLF demonstrated significantly higher scores for artifacts, noise, and sharpness, respectively (P < 0.01). The overall image quality of SSFSE-C (mean AUCVGC, 0.03; P < 0.01) and SSFSE-DL (mean AUCVGC, 0.23; P < 0.01) was rated as significantly inferior, whereas that of SSFSE-DLF (mean AUCVGC, 0.69) was equivalent or significantly higher (P < 0.01). Conclusion: Using a combination of DL and a sharpening filter markedly increases the image quality of SSFSE of the uterus to the level of the PROPELLER sequence.

30 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
TOTakashi Ota
Takashi Ota
MHMasatoshi Hori
Masatoshi Hori
DBDenis LE BIHAN
Denis LE BIHAN
ヒフヒデユキ フクイ
ヒデユキ フクイ
HOHiromitsu Onishi
Hiromitsu Onishi
NTNoriyuki Tomiyama
Noriyuki Tomiyama
Background: Strong correlation has been reported between tissue water diffusivity and tissue elasticity in the liver. The purpose of this study is to explore the capability of diffusion–based virtual MR elastography (VMRE) in the characterization of liver tumors by extending beyond liver fibrosis assessments. Methods: Fifty-four patients (56 liver tumors: hepatocellular carcinoma (HCC), 31; metastases, 25) who underwent MRE, diffusion-weighted imaging (DWI) (b: 0, 800 s/mm2), and VMRE (b: 200, 1500 s/mm2) were enrolled. The MRE shear modulus (µMRE), apparent diffusion coefficient (ADC), and shifted ADC (sADC) were obtained. Virtual stiffness (µdiff) was estimated from the relationship between µMRE and sADC. A linear discriminant analysis combining VMRE and MRE to classify HCC and metastases was performed in a training cohort (thirty-two patients) to estimate a classifier (C), and evaluate its accuracy in a testing cohort (twenty-two patients). Pearson’s correlations between µMRE, sADC, and ADC were evaluated. In addition to the discriminant analysis, a receiver operating characteristic (ROC) curve was used to assess the discrimination capability between HCC and metastases. Results: The correlations between µMRE and sADC were significant for liver, HCC, and metastases (r = 0.91, 0.68, 0.71; all p < 0.05). Those between µMRE and ADC were weaker and significant only for metastases (r = 0.17, 0.20, 0.55). µdiff values were not significantly different between HCC and metastases (p = 0.56). Areas under the curves (AUC) to differentiate HCC from metastases were as follows: VMRE, 0.46; MRE alone, 0.89; MRE + VMRE, 0.96. The classifier C also provided better performance than MRE alone, in terms of sensitivity (100 vs. 93.5%, respectively) and specificity (92 vs. 76%, respectively, p = 0.046). Conclusions: The correlation between sADC and µMRE was strong both in the liver and in tumors. However, VMRE alone could not classify HCC and metastases. The combination of MRE and VMRE, however, allowed discriminant performance between HCC and metastases.

14 December 2014 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
TTTakahiro Tsuboyama
Takahiro Tsuboyama
KYKazuhiro Yamamoto
Kazuhiro Yamamoto
GNGo Nakai
Go Nakai
TYTakashi Yamada
Takashi Yamada
SFSatoe Fujiwara
Satoe Fujiwara
YNYoshifumi Narumi
Yoshifumi Narumi