Rujing Yan

Prof. Dr. Rujing Yan


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 July 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
JFJunqiu Fan
Junqiu Fan
Jing ZhangJing Zhang
Jing Zhang
LYLong Yuan
Long Yuan
RYRujing Yan
Rujing Yan
YHYu He
Yu He
NNNang Nin
Nang Nin
Integrating carbon capture and storage (CCS) technology into an integrated energy system (IES) can reduce its carbon emissions and enhance its low-carbon performance. However, the full CCS of flue gas displays a strong coupling between lean and rich liquor as carbon dioxide liquid absorbents. Its integration into IESs with a high penetration level of renewables results in insufficient flexibility and renewable curtailment. In addition, integrating split-flow CCS of flue gas facilitates a short capture time, giving priority to renewable energy. To address these limitations, this paper develops a carbon capture, utilization, and storage (CCUS) method, into which storage tanks for lean and rich liquor and a two-stage power-to-gas (P2G) system with multiple utilizations of hydrogen including a fuel cell and a hydrogen-blended CHP unit are introduced. The CCUS is integrated into an IES to build an electricity–heat–hydrogen–gas IES. Accordingly, a deep low-carbon economic optimization strategy for this IES, which considers stepwise carbon trading, coal consumption, renewable curtailment penalties, and gas purchasing costs, is proposed. The effects of CCUS, the two-stage P2G system, and stepwise carbon trading on the performance of this IES are analyzed through a case-comparative analysis. The results show that the proposed method allows for a significant reduction in both carbon emissions and total operational costs. It outperforms the IES without CCUS with an 8.8% cost reduction and a 70.11% reduction in carbon emissions. Compared to the IES integrating full CCS, the proposed method yields reductions of 6.5% in costs and 24.7% in emissions. Furthermore, the addition of a two-stage P2G system with multiple utilizations of hydrogen further amplifies these benefits, cutting costs by 13.97% and emissions by 12.32%. In addition, integrating CCUS into IESs enables the full consumption of renewables and expands hydrogen utilization, and the renewable consumption proportion in IESs can reach 69.23%.

2 April 2024 in Sustainability
Verified
Journal Article
Open access
PDF file
MWMou m Wu
Mou m Wu
JFJunqiu Fan
Junqiu Fan
RYRujing Yan
Rujing Yan
XHXiangxie Hu
Xiangxie Hu
Jing ZhangJing Zhang
Jing Zhang
DSDa Song
Da Song
The insufficient flexibility of the hybrid renewable integrated energy system (HRIES) causes renewable power curtailment and weak operational performance. The regulation potential of flexible buildings is an effective method for handling this problem. This paper builds a regulation model of flexible heat load according to the dynamic heat characteristics and heat comfort elastic interval of the buildings, as well as a regulation model of the flexible electrical load based on its transferability, resectability, and rigidity. An operation optimization model, which incorporates flexible regulation of multiple loads and a variable load of devices, is then developed. A case study is presented to analyze the regulation and synergy mechanisms of different types of loads. Its results show a saturation effect between heat and electrical loads in increasing renewable energy consumption and a synergistic effect in decreasing the operating cost. This synergy can reduce the operating cost by 0.73%. Furthermore, the operating cost can be reduced by 15.13% and the curtailment rate of renewable energy can be decreased by 12.08% when the flexible electrical and heat loads are integrated into the operation optimization of HRIES.

5 March 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
MWMou m Wu
Mou m Wu
FJFan Junqiu
Fan Junqiu
RYRujing Yan
Rujing Yan
XHXiangxie Hu
Xiangxie Hu
Jing ZhangJing Zhang
Jing Zhang
DSDa Song
Da Song
The insufficient flexibility of the hybrid renewable integrated energy system (HRIES) makes it difficult to accommodate renewable energy with a high proportion. It is thus necessary to excavate its potential flexibility to improve its operational performance and consume renewable energy. This paper unlocks the adjustment potential of flexible buildings and builds a flexible thermal load regulation model according to the dynamic thermal characteristics and thermal comfort elastic interval of the buildings and a regulation model of the flexible electrical load based on its transferability, resectability, and rigidity. An operation optimization model, which incorporates multiple flexible load regulations and the variable load of devices, is then developed. A case study is presented to analyze the regulation and synergy mechanism in different types of flexible loads. Its results show a saturation effect between the flexible thermal and electrical loads in increasing renewable energy consumption and a synergy effect in decreasing the total cost. This synergy can reduce the total cost by 0.73%. Besides, the total cost can be reduced by 15.13%, and the renewable energy curtailment rate can decrease by 12.08% if the flexible electric and thermal loads are integrated into the operation optimization of HRIES.